Effect of Steel Fibre Reinforced High Performance Concrete Exterior Beam Column Joint Subjected To Cyclic Loading

DOI : 10.17577/IJERTV3IS090682

Download Full-Text PDF Cite this Publication

Text Only Version

Effect of Steel Fibre Reinforced High Performance Concrete Exterior Beam Column Joint Subjected To Cyclic Loading

Asif Abdul Vahab

PG student: Department of Civil Engineering Mar Baselios College of Engineering and Technology

Nalanchira,Trivandrum, Kerala, India

Ajimon Thomas

Asst. Professor: Department of Civil Engineering Mar Baselios College of Engineering and Technology

Nalanchira,Trivandrum, Kerala, India

Abstract Beam-column joint is a typical lateral and vertical load resisting member in reinforced concrete structures which are mainly prone to failures during earthquake. Their constituent materials have limited strength and the joints have limited force carrying capacity. When forces larger than these are applied during earthquake, joints are severely damaged. In this study M50 grade high performance concrete for 5%, 7.5%, 10% and 12.5% replacement of cement with silica fumes were prepared and comprehensive tests have been conducted to find its strength and resistance to chloride ion penetration. The optimum replacement percentage of silica fume was found out and is then used to cast high performance concrete (HPC) exterior beam column joints. The optimum volume fraction of steel fibre in HPC was found out to be 1%. A comparative study between behaviour of steel fibre reinforced high performance concrete (SFRHPC) and High performance concrete exterior beam column joints subjected to cyclic loading were carried out. It was found that the ultimate load of SFRHPC exterior beam column joints were 15.3% higher than HPC beam column joints. The total energy absorption capacity of SFRHPC specimens were 37% more than HPC specimens. The displacement ductility factor of SFRHPC specimen was 9.83% higher than HPC specimens and the curvature ductility factor of SFRHPC specimen was 9.61% higher than HPC specimens. Results showed a better performance for SFRHPC exterior beam column joint compared to HPC exterior beam column joint subjected to cyclic loading.

KeywordsHigh performance concrete, Steel fibre reinforced high performance concrete, Silica fume, Chloride ion, Energy absorption capacity, Ductility factor

  1. INTRODUCTION

    Recently, a large number of concrete highway bridges, concrete dams and nuclear power plants and other offshore structures have been vastly constructed in many countries. These structures constructed during the past have suffered from safety and serviceability problems due to deterioration of concrete, and thus the durability of concrete has received great importance. Although concrete is a very durable material, the environmental factors such as weathering action, chemical attack, abrasion and other deterioration processes may change the properties of concrete with time, and the structures finally reach the end of service life due to lack of safety and serviceability. Any concrete

    which satisfies certain criteria proposed to overcome limitations of conventional concretes may be called high performance concrete [1]. Since high resistance to chloride penetration can be directly related to low permeability that dominates the deterioration process in concrete structures, the resistance to chloride penetration is one of the simplest measures to determine the durability of concrete. Thus, high- performance concrete is a concrete having high resistance to chloride penetration as well as high strength. The presence of micro cracks in the mortar -aggregate interface is responsible for the inherent weakness of plain concrete. The weakness can be removed by inclusion of fibres in the mixture [2]. The addition of fibres to concrete has been shown to increase strength, ductility and fatigue strength of concrete. When fibres are added to concrete, tensile strain in the neighbourhood of fibres improves significantly [3]. Fibre reinforced high performance concrete can be effectively used in RCC members subjected to extreme loading conditions such as seismic loading, blast loading and impact loading. In Reinforced Concrete buildings, portion of columns that are common to beams at their intersections are called Beam-Column joint. Beam-column joint is a typical lateral and vertical load resisting member in reinforced concrete structures which are mainly prone to failures during earthquake [4]. Since their constituent materials have limited strengths, the joints have limited force carrying capacity. When forces larger than these are applied during earthquakes, joints are severely damaged. Repairing damaged joints is difficult, and so damage must be avoided. Thus, beam-column joints must be able to resist earthquake effects.

  2. SCOPE OF THE STUDY

    In this study high performance concrete (HPC) of design strength 50MPa for 0%, 2.5%, 5%, 7.5%, 10% and 12.5% replacement of cement with silica fumes are to be prepared and comprehensive tests are to be conducted to find the hardened mechanical properties and resistance to chloride ion penetration. The optimum replacement percentage of silica fume is to be found out and is then used to cast high performance concrete exterior beam column joints. Three volume fractions 0.5%, 1%, 1.5% of steel fibre were studied and the optimum volume fraction of steel fibre was found out and it is then used to prepare SFRHPC exterior beam column

    joint. This study aims at finding the behaviour of SFRHPC exterior beam column joint subjected to cyclic loading.

  3. EXPERIMENTAL INVESTIGATION

    1. Determination of properties of materials

      Define The constituent materials consist of Portland Pozzolana Cement (PPC) of standard consistency 34percent, specific gravity 2.9 with 28 day compressive strength 33MPa, Quarry sand confirming to Zone II of IS:383 (1970) as fine aggregate, and coarse aggregate of 20mm nominal size [5]. The water absorption of natural coarse aggregate was found to be 1 percent. Tests were conducted as per IS 2386 -part III (1963) for fine aggregate and as per IS:383(1970) for coarse aggregate to determine the different physical properties and are tabulated in Table 1 [6]. The superplasticizer used was CONPLAST SP-430 superplasticizer of specific gravity 1.18 and the specific gravity of silica fume used was 2.2. The chloride and sulphide content in water were found to be 17.5mg/l and 8mg/l respectively. The steel fibre used was crimped steel fibre with an aspect ratio of 50. Mechanical properties, namely, compressive strength, tensile strength, modulus of elasticity and modulus of rupture were determined.

      TABLE 1. PROPERTIES OF AGGREGATES

      Properties

      Fine aggregate

      Coarse Aggregate

      Specific gravity

      2.47

      2.76

      Sieve analysis

      Conforming to zone II of IS:383(1970)

      Conforming to 20 mm graded aggregate

      IS:383(1970)

      Water absorption

      1.75 percent

      0.75 percent

      Bulk density

      1710 kg/m3

      1540 kg/m3

      Fineness Modulus

      2.75

      5.99

    2. Mix Proportioning

      Proportioning of constituents was carried out by the method proposed by Aïtcin [7]. The method itself is very simple and it follows the same approach as ACI 2111(1991) Standard Practice for Selecting Proportions for Normal, Heavyweight and Mass Concrete [8]. It is a combination of empirical results and mathematical calculations based on the absolute volume method. The water contributed by the superplasticizer is considered as part of the mixing ater. The mix proportions for various mixes for 1m3 concrete is given in Table.2.

      Workability tests were conducted using slump test, for fresh concrete as per IS specifications, keeping the dosage of superplasticizer as constant at 2 percent by weight of binder. For the compressive strength determination, 150mm x150mm x150mm specimens were used. 150mm diameter and 300 mm height cylinders were used for determining the split tensile strength and modulus of elasticity. The flexural tensile strength test prisms of size 100mmx100mm x500mm were used. All the specimens were moist cured underwater at room temperature until testing. Each strength value was the average of the strength of three specimens. The optimum volume fraction addition of steel fibre on high performance concrete was found out using workability test by maintaining a contant slump of 120mm by varying the super plasticizer dosage for

      varying volume fraction addition of steel fibers used for the study.

      TABLE 2. MIX PROPORTION FOR VARIOUS MIXES

      Volume replacement ratio of Silica Fume

      (%)

      Water (kg)

      Cement (kg)

      Silica Fume (kg)

      Coarse Aggre gate (kg)

      Fine Aggre gate (kg)

      Super plastici zer (liters)

      0

      163

      455

      0

      1070

      680

      9.5

      2.5

      163

      443

      11

      1070

      680

      9.5

      5.0

      163

      432

      23

      1070

      680

      9.5

      7.5

      163

      420

      35

      1070

      680

      9.5

      10.0

      163

      410

      45

      1070

      680

      9.5

      12.5

      163

      400

      32

      1070

      680

      9.5

    3. RCPT test for finding the chloride ion penetration

      In order to find the chloride ion penetration of HPC, Rapid Chloride ion Penetration Test (RCPT) was conducted as per ASTM C 1202 as shown in Table 3 [9]. For this, specimens of size 100mm diameter and 50mm thick were prepared. After 28 days of curing, the specimens were coated with epoxy and were vacuum saturated for 3 hours and then soaked for 18 hours. The specimens were then placed in the testing apparatus, where one end of the specimen is exposed to a solution containing sodium chloride (NaCl) and the other end is exposed to a solution containing sodium hydroxide (NaOH). To increase the rate of chloride penetration into the specimen, thus speeding up the test, a constant 60 V potential is applied across the specimen. . The current across the specimen is measured at an interval of 30 minutes during the 6-hour test and the results obtained were then compared with standard values. Berkes equation was used to calculate the Chloride Migration Diffusion Coefficient.

      TABLE 3. CHLORIDE ION PERMEABILITY BASED ON CHARGE PASSED

      Charge passed(coulombs)

      Chloride ion

      penetrability

      >4000

      High

      2000-4000

      Moderate

      1000-2000

      Low

      100-1000

      Very low

      <100

      Negligible

    4. Test on Exterior Beam Column Joint

    In the beam column joint, column dimension is 200mmx200mm cross -section and 1m length, beam dimension is 150mmx 200mm cross-section and 80 cm length. The reinforcement detailing as shown in Fig. 1 includes 4 numbers of 10mm dia. bars for column and 2 numbers of 8mm dia. bars at top and 2 numbers of 10mm dia. bars at the bottom for beam and 6mm stirrups are provided at a spacing of 120 mm c/c. The number of exterior beam column joints used for the study includes 3 numbers of HPC specimens and 3 numbers of SFRHPC specimens.

    Figure 1. Detailing of reinforcement

    The exterior beam column joint test setup is as shown in Fig. 2. From the observed results, Load deflection graph was plotted from which envelope curve, energy absorption, stiffness degradation and displacement ductility factor was found out for HPC and SFRHPC specimens. The strain measurements were used to obtain the moment curvature plot and curvature ductility factor.

    Figure 2. Exterior Beam Column Joint subjected to cyclic loading Test Setup

  4. RESULTS ND DISCUSSIONS

    1. Hardened Properties of HPC

      The results of different tests such as cube compressive strength, cylinder compressive strength, flexural strength, and modulus of elasticity for different percentage replacement of silica fume is given in Table 4. All the test results show an increasing trend up to a percentage volume replacement of 7.5%. This is due to increase in strength characteristics due to the pozzolanic reaction of amorphous silica present in the silica fume. The strength of concrete is found to be decreasing when the replacement ratio is greater than 7.5 percent. The CaO content in the silica fume is

      relatively lower compared to cement .Even though the strength decreases after silica fume replacement of 7.5 %, the grade of concrete required of M50 was obtained for silica fume replacement of 10 % .Since silica fume is cheaper than cement ,10% re placement of cement with silica fume is considered as optimum replacement percentage.

      TABLE 4. HARDENED PROPERTIES OF HPC FOR VARYING PERCENTAGE OF SILICA FUME

      Volume replacem ent ratio of Silica Fume (%)

      Cube Compre ssive Strengt h (N/mm2

      )

      Cylinder Compres sive Strength (N/mm2)

      Split Tensile Strength (N/mm2)

      Flexural Strength

      (N/mm2)

      Modulus of Elasticity (x103

      N/mm2)

      0

      54.0

      42.0

      3.1

      6.4

      32

      2.5

      57.5

      44.5

      3.2

      6.4

      32.5

      5.0

      61.0

      46.0

      3.2

      6.9

      33

      7.5

      62.5

      49.5

      3.6

      7.4

      35.5

      10.0

      60.0

      48.5

      2.9

      6.2

      34

      12.5

      54.0

      41.5

      2.8

      5.4

      30

    2. Result of RCPT Test on Hpc

      The total charge passed through the concrete specimen was found to be decreasing with increase in percentage replacement of cement with silica. The chloride diffusion coefficients shows that the specimen with highest replacement had the lowest diffusion coefficient and specimen with minimum replacement had the highest diffusion coefficient. From this, it can be inferred that the chloride ion penetration and the diffusion coefficient decreases as the replacement percentage increases. The better chloride resistance of silica fume blended concretes is due to high refinement of the pore structure. The charge passed through each specimen and diffusion coefficient for varying replacement percentage of silica fume is given in Table 5.

      TABLE 5. CURRENT PASSED THROUGH EACH SPECIMEN AND DIFFUSION COEFFICIENT

      Percentage Replacement

      Calculated Charge (Coulombs)

      Corrected Charge (Coulombs)

      Chloride Ion Penetrability

      Chloride Diffusion Coefficient

      0

      082.7

      974.43

      Very Low

      3.34 x 10-12

      2.5

      945.7

      851.2

      Very Low

      3.34 x 10-12

      5.0

      917.1

      825.4

      Very Low

      2.90x 10-12

      7.5

      823.5

      741.1

      Very Low

      2.65 x 10-12

      10.0

      774.3

      686.8

      Very Low

      2.48 x 10-12

      12.5

      661.5

      595.4

      Very Low

      2.20x 10-12

    3. Exterior Beam Column Joint Subjected to Cyclic Loading Test Results

    1) Behaviour of Specimens

    In all specimens cracks appeared at the beam column interface after the first crack load. With further increase in loading, the crack propagated and the initial crack started widening. The ultimate load and corresponding deflection of specimens were found to increase as the fibre content increased. The typical failure pattern of HPC and SFRHPC beam column joints are shown in Figure 3 and Figure 4 respectively

    Figure 3. Failure pattern of HPC beam column joint subjected to cyclic loading

    Figure 4. Failure pattern of SFRHPC beam column joint subjected to cyclic loading

    TABLE 6. FIRST CRACK LOAD AND ULTIMATE LOAD OF HPC AND SFRHPC BEAM COLUMN JOINT

    Specimen

    First Crack

    Load (kN)

    Ultimate Load (kN)

    HPC

    8

    21.5

    SFRHPC

    9

    24.8

    3) Load Deflection Behaviour

    The load deflection plot of HPC and SFRHPC exterior beam column joints subjected to cyclic loading are shown in Fig. 5 and Fig. 6 respectively. It can be seen that the stiffness decreases with increase in load value for both HPC and SFRHPC exterior beam column joint. The envelope curve is obtained by joining the peak points of each cycle. Important parameters like energy absorption capacity, stiffness, displacement ductility factor were evaluated from this load deflection plot.

    Figure 5. Load Defection Plot of HPC specimen

    2) Ultimate Load

    The first crack load and ultimate load of HPC and SFRHPC have been found out and are given in Table 6. The results shows an increase of about 12.5% in the first crack load and 15.3% in the ultimate load for the SFRHPC specimens compared to HPC specimens. When the micro cracks develop in the matrix, fibres intercept the cracks and prevent them from propagating in the same direction. Hence the cracks need to take a deviated path which requires more energy for further propagation, thus resulting in higher load carrying capacity.

    Figure 5. Load Defection Plot of SFRHPC specimen

    1. Energy Absorption Capacity

      The area under the load deflection curve represents the energy absorption capacity of the specimen. The energy absorption during each cycle of HPC and SFRHPC load deflection curve is given in Table 7. The total energy absorption capacity of HPC and SFRHPC specimens were 737.74kNmm and 1011.34kNmm respectively.

      TABLE 7. ENERGY ABSORPTION CAPACITY OF HPC AND SFRHPC IN EACH CYCLE

      Cycle No.

      Energy absorbed in each

      cycle (kNmm)

      HPC

      SFRHPC

      1

      6.85

      7.55

      2

      29.3

      30.43

      3

      134.5

      135.85

      4

      238.25

      268.05

      5

      328.5

      570.97

    2. Stiffness

      Stiffness is defined as the load required to cause unit deflection of the beam-column joint. The stiffness in each cycle was calculated using a line drawn between the maximum positive displacement point in one half of the cycle and the maximum negative displacement point in the other half of the cycle. Comparing all the specimens , similar degradation trends were observed in HPC and SFRHPC specimens.

    3. Displacement Ductitlity Factor

    Ductility of a structure is its ability to undergo deformation beyond the initial yield deformation while still sustaining load.

    Figure 6. Moment Curvature Plot for HPC Exterior Beam Column Joint

    Figure 7. Moment Curvature Plot for SFRHPC Exterior Beam Column Joint

    8) Curvature Ductility Factor

    The capacity of the member to deform beyond its initial yield deformations with minimum loss of strength and stiffness depends upon the ductility factor which is defined as the ratio of the ultimate deformation to its yield deformation at first

    Ductility factor = Ultimate displacement

    [10]

    yield. The curvature ductility factor for HPC and SFRHPC exterior beam column joint were found out as shown in

    Yield

    displacement

    Table 8.

    The yield displacement is equal to the displacement corresponding to yield load which is 75% of ultimate load [26]. The displacement ductility factor of HPC and SFRHPC specimens are shown in Table 8. It was found that the displacement ductility factor of SFRHPC specimen was 9.83% greater than HPC specimen

    1. Moment Curvature Behaviour

      The values of moment M were calculated using the experimental values of load and lever arm. The moment M, curvature ductility at peak load and yield load are shown in Table 8. The values of M and were used to plot the moment curvature were used to obtain moment curvature plot for the joint. Fig. 6 and Fig. 7 shows the moment curvature plot for the HPC and SFRHPC exterior beam column joint respectively.

      TABLE 8. MOMENT AND DUCTILITY FACTORS OF HPC AND SFRHPC SPECIMEN

      Specimen

      Displacement Ductility Factor

      Curvature at Ultimate Load × 10-3 rad/m

      Moment at Ultimate Load

      (kNm)

      Curvature Ductility Factor

      HPC

      1.73

      12.75

      16.125

      1.31

      SFRHPC

      1.9

      15.24

      18.6

      1.436

  5. CONCLUSION

      • In HPC, 10% replacement of cement with silica fume was found out as the optimum replacement percentage.

      • The chloride ion penetration decreases with increase in replacement percentage of silica fume.

      • The optimum volume fraction of steel fibre was found out as 1%.

      • The chloride ion penetration for SFRHPC specimens was higher than HPC specimens.

      • There was an increase of about 12.5% in the first crack load and 15.3% in the ultimate load for the SFRHPC compared to HPC exterior beam column joint specimens when subjected to cyclic loading.

      • The total energy absorption capacity of SFRHPC specimens were 37 % more than HPC specimens.

      • The stiffness degradation of SFRHPC specimen was less than HPC specimens for the first 4 cycles and was more for the last cycle.

      • Displacement ductility factor of SFRHPC specimen was 9.83% higher than HPC specimens.

      • Curvature ductility factor of SFRHPC specimen was 9.61% higher than HPC specimens.

    Thus it was found that SFRHPC exterior beam column joint had better performance when compared to HPC exterior beam column joint.

  6. ACKNOWLEDGMENT

The authors gratefully acknowledge the financial support received from Kerala State Council for Science, Technology and Environment, Thiruvananthapuram, Kerala.

REFERENCES

  1. Iqbal, M. K.,Comparison of chloride ion penetration and diffusion of high performance concrete, KSCE ournal of Civil Engineering, 5, 2001, pp 490-498.

  2. Shende, A. M,, Pande, A. M., Gulfham, M. P., Experimental Study on Steel Fiber Reinforced Concrete for M-40 Grade, International Refereed Journal of Engineering and Science (IRJES), 1 (1), 2012, pp 43-48.

  3. Ganesan, N., Indira, P. V., Ruby, A., Steel fibre reinforced high performance concrete beam-column joints subjected to cyclic loading ISET Journal of Earthquake Technology, 44(3 ), 2007, pp 445456 .

  4. Durai, S., Boobalan, S., Muthupriya, P., Venkatasubramani, R., Behaviour of high performance concrete in exterior beam-column joint- a general review, Indian Journal of Engineering, 3(6), 2013.

  5. IS 2386 (Part III):1963 (Reaffirmed 2002), Methods of Test for Aggregates for Concrete , Bureau of Indian Standards, New Delhi, India, 1997.

  6. IS 383:1970 (Reaffirmed 1997), Specifications For Coarse And Fine Aggregate From Natural Sources For Concrete, Bureau of Indian Standards, New Delhi, India, 1993.

  7. Aitcin, P. C., High Performance Concrete, Modern Concrete Technology, London, 1998.

  8. ACI 211.1-91, Standard Practice for Selecting Proportions for Normal, Heavyweight, and Mass Concrete, 1991.

  9. ASTM C1202, Standard Test Method for Electrical Indication of Concretes Ability to Resist Chloride Ion Penetration, American Society for Testing and Materials Standard Practice, Philadelphia, Pennsylvania, 1997.

  10. Park. R., Ductility Evaluation from Laborotary and Analytitcal Testing, Proceedings of ninth world conference, Vol. 8, 1988.

Leave a Reply