Hydraulic Study of Minimizing Energy Consumption in Storm Water Pumping Station Suction Side

DOI : 10.17577/IJERTV3IS030435

Download Full-Text PDF Cite this Publication

  • Open Access
  • Total Downloads : 458
  • Authors : Prof. Dr. Hayder Abdulameer K. Al-Thamiry , Dr . Hasan Mahdi M. Al-Khateeb, Riyadh Mahdi L. Albonassiriya
  • Paper ID : IJERTV3IS030435
  • Volume & Issue : Volume 03, Issue 03 (March 2014)
  • Published (First Online): 14-03-2014
  • ISSN (Online) : 2278-0181
  • Publisher Name : IJERT
  • License: Creative Commons License This work is licensed under a Creative Commons Attribution 4.0 International License

Text Only Version

Hydraulic Study of Minimizing Energy Consumption in Storm Water Pumping Station Suction Side

Asst. Prof. Dr. Hayder Abdulameer K. AL-Thamiry

University of Baghdad

Faculty of Engineering/Water Resource Dep.

Baghdad- Iraq

Dr. Hasan Mahdi M. Al-Khateeb

University of Kufa

Faculty of Engineering/ Civil Eng. Dep.

Najaf- Iraq

Riyadh Mahdi L. Albonassiriya

University of Kufa

Faculty of Engineering/ Civil Eng. Dep.

Najaf- Iraq

Abstract One of the important factors effecting the efficiency of pumped-storage power stations is the losses induced at the hydraulic waterways. One part of the hydraulic waterways is the intake-inlet structure at the wet basin of the station.

Through this study, a physical hydraulic model was constructed with typical relative dimensions derived from common design guidelines, to simulate storm water pumping stations adopted in Iraq. Sensitive and accurate measurement devices were used in the model to measure water flow, power and pressure.

This research aims to determine the hydraulic effect of suction pipe size and inlet configuration as provided with bell- mouth end. This effect was investigated through observing the saving in energy consumed by the pump, and pressure reduction detected at the inlet section. Variables considered in the experiments curried out during this study were; suction pipe position (90º elbows), suction pipe diameters (5.08cm, 7.62cm and 10.16cm), and using bell-mouth inlet with different flow velocities. The results, generally, indicate that there is energy saving when using bell-mouth and when increasing suction pipe diameter. The best installation was through using bell-mouth with (10.16) cm pipe diameter were give best specific energy (power

/flow rate) . On the other hand, The Largest energy saving of bell-mouth effect is recorded when using bell-mouth with (5.08)cm pipe diameter .

KEYWORDS: inlet suction pipe, bell-mouth, pump sump, vortices

  1. INTRODUCTION

    wastewater lift stations shall be designed to satisfy the hydraulic conditions of the planned facility. The pump head shall be determined as accurately as possible taking into account all majar and minor head losses.

    Pump suction pipe design and installation shall not permit the accumulation of air in the suction piping or induce excessive turbulence in the pump suction area. Long radius suction piping bends shall be used whenever possible and eccentric reducers

    are to be used with flat side up to prevent formation of air pockets.; "City of Reno, 2007".

    Pumping stations represent one of hydraulic appliances using electric motors, the biggest consumer of electricity in industry. Pumping systems account for nearly 20% of the worlds electrical energy demand and range from 25-50% of the energy usage in certain industrial plant operations "Europump and Hydraulic Institute, 2001; Xenergy, 1998".

    Wet well and suction pipe intake design of the pump station should be such as to avoid turbulence near the intake and to prevent vortex formation. The most important purpose of this study is to find the energy saving potential in storm pumping systems with focusing up on minimizing local head loss and present suitable hydraulic conditions in suction side. This has been done through choosing suitable inlet pipe diameter, location, shape and using configuration as bell- mouth. It is important to take into consideration in this study the complete pumping system, which consists of pump, pipework, motor and control devices.

    The following variables were investigated in the physical model study:

    • Different suction pipe diameters ;

    • bell-mouth configurations;

    • Different suction pipe flow velocities and

    • Different suction pipe shape and position.

    The experimantal platform (physical model) did not consider some aspects, such as the widening or narrowing of the side wall of pump station, or velocity distributions at the impeller eye. Wet well dimensions of the mpdel was derived from previous researches. Variable speed drive (varial speed pump) instead of the on-off control has been adopted in controlling flow rate through the model. Energy saving has been detected by means of sensitve power meter device connected to the pump.

  2. EXPERIMENTAL WORK

    This part of study includes comprehensive description for the experimental platform, equipments and devices used in this study. Also, the procedure adopted to carry out the experimental work is described, too.

    As mentioned before, this work highlights on wet well suction pipe side in order to determine and evaluate factors that covering flow hydarulics in this side, and their effect on minor head loss, hence power saving potential.

    Geometric dimensions of wet well pump basin has bean designed and built on the basis of available researches and design guidelines that ensure a regular flow to the pump without cavitation or palpitations.

    • Modeling experimental platform tank dimensions

      As usual, when facing difficulties in providing hydraulic conditions in a model because of prototype to model scaling ratio, smaller scale ratio should be used to minimize model dimensions, and hence achieving and controlling hydraulic conditions needed, and taking into account the cost factor. On this basis, the physical models are constructed with minimum dimensions that accomplish desired flow conditions, such as turbulent flow and high Weber number with a consideration of geometric scale ratio within 1:41:25.;"Prosser, 1977". Accordingly, the dimensions used in constructing the physical model were within this range as compared with typical storm water pumping stations, and satisfy the minimum recommended Reynolds and Weber numbers of 4×103 and 11, respectively.

      The experimental platform tank dimension expressed as follows:

      • For experimental Platform basin depth, the pump basin depth must be ensured to meet all water level requirements in the test, the minimum water depth in the basin related with inlet velocity then inlet diameter (D). Throguh reviewing available literature for appropriate pipe diameter, largest pipe diameter used in this study was (10.16cm). On the other hand, to avoid vorticies formation, the depth must be more than critical submergence. Figure (1) shows critical submergence for this purpose.

        From previous research, it has been found that critical submergence Sc1.5D.; " Prosser, 1977; Knauss, 1987". And also, it has found that critical submergence, Sc=D(1+2.3Fr).; "Hydraulic Institute, 1998; Karassik et al., 2001".

          1. D.; "Flygt, 2002". However submergence of S=2.5D has been used in this study to preventing surface vortices formation or at least to be reduced significantly.

            Regarding the distance between the inlet pipe and basin floor (C) as in Figure ( 1), the referable distance mentioned in the literature is 0.5D. The value of intak open (D) in this study equal 1.9d for bellmouth design, see Figure (8). As the largest pipe deameter (d) used in this study is 10.16cm, the largest inlet open D is18.288cm.

            As the submergence used in this study is 2.5D, so the max value of submergence operated in this study that corresponds to largest suction pipe diameter used (10.16cm) is 54.8cm. Adding a free board of (25.2cm) to facilitate handling with water inside the tank and fulfill all the requirements. The total depth adopted for the tank was 100 cm. This is to provide all requirements needed, like installing a over flow discharge pipe, and water circulation pipe.

            • For experimental Platform basin width, the minimum requirements for pump basin width is 2D for one pump "Prosser, 1977". There are other width requirements related to the amount of storage required. In addition, the model requires the provision of space to install baffles and to eliminate the hydraulic (interfere) effect of the adjacent walls of pump station. Basin width has been duplicated around three times to be as 1.2m. This width provide also suitable space to handle the fittings inside model tank.

              • For experimental Platform basin length, the distance from centerline of pump inlet bell/volute to screen 4D, "Federal Highway Administration, 2001; American National Standard ANSI/HI 9.8-1998; Karassik, 2008". Accordingly,the experimental Platform basin length needed is (4D+B) thats equal to (86.8cm). Adding 13cm for tranch width, leading to experimental Platform basin length as (99.9cm). The length adopted in this study was L(model)

        =100cm

    • Pump capacity:

      Flow velocity in pipeline has to be kept less than or equl to 4 m/s. "Sulzer Pump Ltd, 2010". Pump capacity used in the physical model satisfys this condition, and provide turbulent discharge in all used suction pipes, as well as stability of the measurement devices used. To investigate effect of different suction pipe flow velocities of the model (up to 4 m/s), with smallest diameter used in the tests (0.0508m), the following steps were adopted to determine pump power :

      The power of the driver can be calculated from the well known equation:

      d

      P = g Q H

      p m

      ; "Europump and Hydraulic Institute,

      Figure (1). Inlet position (Knauss, 1987)

      Some other literature stated that critical submergence is Sc=1.7Fr, which means that critical submergence greater than

      2001".

      The flow rate Q is:-

      Q=A*v= (0.0508)2/4*4=0.008107 m3/s.

      The total head H can be claculated using the equation:-

      H = H + (f L + ) v2 .;"Groundfos

      geod D 2g

      westwater,2002 "

      For a pipe diameter of (0.0508m) carrying the discharge (0.008107 m3/s) above, Reynolds number is 203200. Using Moody diagram, friction factor f= 0.027. local resistance () is

      0.3 for 90ºelbow of 2 inch PVC pipe, with six 90º elbows, with flow velocity vm = 4m/s , Hgeod=2.4m, and 10m long PVC discharge pipe (with the same diameter of 0.0508m), the total head H is:-

      H = 2.4 + (0.027 10

      0.0508

      m

      + 60.3 ) 42

      2 9.81

      =8.202

      Using pump effeciency as 0.75 and pump motor effeciency as 0.8, the pump actual (overall) power is ,

      d

      P = 98100.00818.202 = 1086.23 Watt 0.80.75

      Figure (3). Front view details for Experimental model of the study

      Using variable speed driver efficiency as 0.97, so, Pd =1086.23 /0.97 = 1119.82 Watt

      Pd = 1119.82 /746 = 1.5 hp

      The driver should not operate continuously at its maximum capacity, but at an 85 to 90% load so:

      Pd= 1.5/0.85= 1.77 hp

      According to commercial availablity, a centrifugal pump with three phase of 2.2 hp , (1.65 KW) power was used in the model.

    • Description of experimental platform (model)

      Experimental platform has been designed and built in such a way to allow testing all variables and experiments needed in this study Figures (2), (3), (4), (5),(6), and (7) . The model has been built in the Labs of Faculty of Engineering in Kufa University.

      Figure (2). schematic diagram of the experimental model of the study.

      Figure (4). Side view for the experimental platform of the study

      d=0.0508m.

      d=0.0508m, with bell-

      mouth

      Figure (5). The manufactured flange and the adopted configurations for 5.08cm diameter suction pipe.

      d=0.0762m

      d=0.762m, with bell-mouth

      d mm

      D (mm)

      H

      R

      D= d ×1.9

      H=d

      D×0.267

      50.8

      96.52

      50.8

      25.77

      76.2

      144.78

      76.2

      38.65

      101.6

      193.04

      101.6

      51.54

      Where, d: suction pipe diameter, H: Bell-mouth hight , R:

      Bell-moth sid wall carve , and D: Bell-moth inlet open diameter .

      diameter used in the test. Table (2) Illustrates scaled dimensions of bell-mouths for each pipe diameter used in the test .

      Table (1).Bell-mouth dimensions adopted

      Figure (6).The manufactured flange and the adopted configurations for 7.62cm diameter suction pipe.

      d=0.1016 m

      d=0.1016m, with bell-mouth

      Figure (7). The manufactured flange and the adopted configurations for 10.16cm diameter suction pipe.

    • Pressure gauges

      The model was provided with a mechanical pressure gauge on discharge pipe and digital pressure gauge on suction. This digital gauge is operatedly 9V-DC battery power , with zero offset, and accuracy of +/-0.5% F.S (full scale), LCD digital display with 4 digits with response time less than 1ms, and total error (typical) of +/-1.00%.

    • Bell-mouth dimension

      To facilitate the flow smoothly into the inlet pipe and reduce (minimize) inlet losses and disturbed flow into the pump, the inlet should be provided with a bell-mouth. Most pump manufacturers use the following ratio of bell-mouth diameter (D) to pump suction opening (d), as D/d = 1.5 to 1.8. In general, most design guidelines (Hydraulic Institute Standards,1975; Prosser, 1977; Knauss, 1987) suggest that the pump bell diameter be between 1.5 to 1.8 times the diameter of the discharge pipe.; "Frizell K. W., 1994". Other design guidelines state that bell diameter approximately 1.52.0 times the inside pip diameter., "American National Standard for Pump Intake Design(ANSI/HI) ,1998; Karassik, 2008".

      Bell-mouths designed and fabricated to be fit with inlet pipe sizes, hence, it designed with inlet open diameter equal to

      1.9 times the inside diameter of suction pipe. It is designed and casted as in Figure (8) and Figure(9). Figure(10) shows three sizes of bell-mouth at same scale ratio with pipe

      Figure (8). Bell-mouth details adopted in the study

      Figure (9).Bell-mouth fabrication through the study

      Figure (10).Three sizes of bell-mouth at same scale ratio with pipe diameter

    • Flow meter

      Digital flowmeter type ( EESIFLO 6000) was used in the experimental work. It was ultrasonic signals to measure the flow

      in pipes or conduits, Figure( 11) .

      With a special probe, can also measure the thickness of pipe walls.

      The transducers of the flowmeter can be used at temperatures between -30°C and 130°C. Measurement can be made on all commonly used pipe materials such as steel, synthetic material, glass or copper. Pipe diameters may range from 10 up to 6500 millimeters depending on the transducer type. The two clamp-on transducers allow for non-invasive measurement that do not affect the pipework or the liquid to be measured.

      Figure(11).front view of digital flow meter

    • Variable speed driver system

      Variabe speed driver system (VSDs) type (SV-iG5A) frequency inverter was used in the experimantal wark. It is utilizing three phase with 2hp power figure (12). Its suitable as variable flow driver as itis needed in this study.

      Figure (12).Variable speed driver(VSD)

    • Balancing storage tank

      Additional water storage tank with storage cappacity of 1m3 was used to feed testing platform and to controll water temperature prior to be supplied into the model. To transport water to and from the Balancing storage tank, two pumps have been used. One of them was to feed the model and the other was to transfer water from the model to balancing storage tank .

    • Constants used in the tests

      There were some constant dimensions adopted in the tests, those constants were considered from previous researches as explained in literature review, the constants are shown in Table (2).

      Table(2). Values of constants considered in this study

      Sample

      Description

      Dimension

      C

      Distance between the inlet of suction pipe level and floor

      level

      0.5 D

      B

      Distance from the back face wall to the inlet centerline of

      suction pipe.

      0.75D

      Hgeod

      geodetic head

      2.5 m

      S

      Submergence

      2.5 D

      Where, D is inlet diameter of suction pipe

    • Description of tested scenarios

    Throughout the experimental work, different test runs were accomplished. Suction head wase measured for different cases with different variables. In each case, total power consumption of the overal system (of the pumpe) was measured by mean of power meter, while suction head measured using the digital gauge, and flow were measured by flow meter. For all cases, measures were carried out after 10 minutes of conducted operation to reach stability conditions and ,hence, give trusted observations. Temperature wase maintained within (25.3ºC- 25.9ºC) through all tests, tests senioresas are present in Table (3).

    Pumped water power wase calculated using the common equation:

    Power = Q h

    But, power saving due to using of inlet configration wase calculated as:

    powerSaving = Qh/Qp where:

    : Water Density (Kg m/s) Q: Flow-rate (m3/s)

    h: difference in head (m) = p-p

    p= Suction head in meters without using of bellmouth, (m), p=ps1*0.703

    p= Suction head in meters with use bellmouth, (m),

    p=ps2*0.703

    Table (3). Seniores of variables tested

    No.

    Suction pipe diameter (cm

    Water Velocity m/s

    With bell-mouth or no

    1

    5.08

    0.15

    yes

    2

    0.15

    no

    3

    0.233

    yes

    4

    0.233

    no

    5

    0.367

    yes

    6

    0.367

    no

    7

    0.4

    yes

    8

    0.4

    no

    9

    1

    yes

    10

    1

    no

    No.

    Suction pipe diameter (cm

    Water Velocity m/s

    With bell-mouth or no

    11

    2

    yes

    12

    2

    no

    13

    3

    yes

    14

    3

    no

    12

    7.62

    Steps (1-10) to be repeated with change suction pipe diameter to

    7.62 cm

    13

    10.16

    Steps (1-8) to be repeated with change suction pipe diameter to

    10.16 cm

  3. ANALYSIS AND DISCUSION OF THE RESULTS Results of scenarios tested using the implemented

    physical model and their representing graphs are presented in this section. The results of different cases were analysed to investigate the effects of different variables that governing the present problem.

    The energy consumption under effect of many configurations that consists of three types of pipe diameter and bell mouth, were studied with the variation of Reynolds number. Then, comprehensively, the effects of the main controlling parameters that maximize the hydraulic power saving were displayed.

    Bell-mouth effect through the percentage of power saving with variation of Reynolds number according to three different pipe diameters of 0.0508,0.076 and 0.1016 m are shown in Figures (13),(14) and (15), respetively. The bellmouth effect for 0.0508,0.076 and 0.1016 m inlet pipe diamteres with 90º elbow, all togeather, is presented in Figure (16). From Figure (13),the percentage of power saving for inlet suction pipe of 0.0508 m diameter has highest values of approximately 25% when Reynolds number is greater than 170000.

    30

    25

    Power Saving %

    20

    35

    30

    Power Saving %

    25 cm7.62 d=

    20

    15

    10

    5

    0

    5-

    0 20 40 60 80 100

    Reynolds number × 103

    Figure (14). Percentage of power saving of bell-mouth effect as a function of Reynolds number for (7.62cm) inlet suction pipe diameter.

    Figure (15) reveal percentage of power saving for inlet bell mouth with 0.1016m pipe diameter.In this pairing, it is found that the highest value of percentage of power saving which is approximately 40% occures when Reynolds number is about 17000, It is observed that power saving decreases with increasing Reynolds number till Re=36000 were the saving is rest on about 2.5%.

    45

    40

    Power Saving %

    35 cm10.16 d=

    30

    25

    20

    15

    10

    5

    0

    0 10 20 30 40 50

    Reynolds number ×103

    15

    10

    5 cm5.08 d=

    0

    5-

    0 50 100 150 200

    Reynolds number× 103

    Figure (13). Percentage of power saving of bell-mouth effect as a function of Reynolds number for (5.08cm) inlet suction pipe diameter.

    From Figure (14), the percentage of power saving for inlet pipe of 0.0762 m diameter, gives the highest values of approximately 26% when Reynolds number is around 40000, and be decrease with increasing Reynolds number more.

    Figure (15). Percentage of power saving of bellmouth effect as a function of Reynolds number for (10.16cm) inlet suction pipe diameter.

    Figure (16) shows the comparison between percentage of power saving with bell-mouth in three adopted pipe diameters and 90º elbow. The percentage of power saving of 0.0508m diameter inlet pipe is approximately 13% when Reynolds number is about 20000, and percentage of power saving will increase to the highest value of about 25% with the increasing of Reynolds number to 160000. On the other hand, when Reynolds number is 40000 and more there percentage of power saving decreases in 0.0762m and 0.1016m pipe diameters is generally decreas with increas of reynolds number.

    Symbol Definition Units

    45

    40 Hgeod pump geodetic head m

    35 cm10.16 d=

    Power Saving %

    cm7.62 d=

    30 cm5.08 d=

    25

    20

    15

    10

    5

    0

    HJ pipe losses in the system m

    HL

    Local loss

    m

    Hst

    Static head

    m

    L

    pipe length

    m

    pd

    Required power supply

    W

    Ps1

    Suction pressure without using any configuration

    psi

    Ps2

    Suction pressure with using certain configuration

    psi

    Q

    Flow rate

    m3/s

    Sc

    Critical submergence

    m

    v

    Fluid average velocity

    m/s

    kinematic viscosity.

    m2/s

    Density of the liquid

    kg/m3

    Local resistance coefficient

    0 50 100 150 200

    Reynolds number× 103

    Figure (16). Percentage of power saving as a function of Reynolds number for different suction inlet pipe diameter with bell-mouth.

  4. CONCLUSIONS

    The following main conclusions were obtained:

    1. Increasing the suction pipe diameter lead to decrease specific energy of flow (power per discharge).

    2. The use of bell-mouth has a clear impact in saving energy for all pipe diameters used. For the same Reynolds number tested, highest effect of bell- mouth appeared in the smaller pipe diameters (5.08cm). This explain that bell-mouth is more effective to save power for relatively high flow velocities.

    Although installing bell-mouth at the suction pipe inlet minimizes the head loss, hence, the power consumed, but this effect becomes very clear for relatively high Reynolds number when considered on the basis of the specific power consumed.

    Symbol

    Definition

    Units

    h

    difference in head

    m

    m

    Motor efficiency

    p

    pump efficiency

    d

    Inside pipe diameter

    m

    D

    Inlet suction pipe diameter

    m

    f

    Friction factor

    g

    Acceleration of gravity

    m/s2

    H

    Total head

    m

    p

    Suction head in meters using of configuration

    without

    m

    p

    Suction head in meters configuration

    with

    use

    m

    Hd

    Pump dynamic head

    m

    Hf

    Pipe friction losses

    m

  5. LIST OF SYMBOLS

REFERENCES

  1. American National Standard for Pump Intake Design, ANSI/HI 9.8-1998, Hydraulic Institute, Parsippany.

  2. City of Reno, 2007, Wastewater Lift station Design Standards, Reno, Nevada,USA.

  3. Frizell K. W., 1994, Hydraulic Model Tests :Twin Peaks Pumping plant, U.S. Department of the Interior, Hydraulics Branch, Research and Laboratory, Services Division, Denver Office, Colorado, USA.

  4. Flygt, 2002, Design recommendations for pumping stations with dry installed submersible pumps, Stockholm: Flygt.

  5. Hydraulic Institute, 1998, American national standard for pump intake design. New York: ANSI.

  6. Karassik I. J., Messina J. P., Cooper P. and Heald C.C.,2001, Pump Handbook,third edition, New York, McGraw- Hill. ISBN 0-07-034032-3.

  7. Karassik I. J., Messina J. P., Cooper P., Heald C.C.,2008, Pump Handbook,,Fourth edition, New York, McGraw- Hill. ISBN 978- 0-07-146044-6.

  8. kleynhans Sh., 2012, Physical hydraulic Model Invistigation of Critical Submergence for Raised Pump Intakes, MSc Thesis, Department of Civil Engineering, Stellenbosch University, South Africa.

  9. Knauss J., 1987 Swirling Flow Problems at Intakes, Hydraulic Structures Design Manual, A.A. Balkema, Rotterdam, Netherlands.

  10. Novak P., Moffat A. I. B., Nalluri C., Narayanan R.,1990, Hydraulic Structure,Unwin Hyman, London, Journal of hydrology (NZ) 35(2), PP199-212,1996.

  11. Prosser M. ,1977, The Hydraulic Design of Pump Sumps and Intakes. Bedford, British Hydromechanics Research Association, UK.

  12. Sulzer Pump Ltd, 2010, Centrifugal PumpHandbook, 3rd edition, Butterworth – Heinemann – Elsevier, ISBN13:978-0-75- 068612-9. ,Switzerland.

Leave a Reply