Experimental and Numerical Analysis of Heat Transfer on Plate Fin Heat Exchanger at Different Fin Pitches with Ceramic Coating

DOI : 10.17577/IJERTCONV6IS10010

Download Full-Text PDF Cite this Publication

Text Only Version

Experimental and Numerical Analysis of Heat Transfer on Plate Fin Heat Exchanger at Different Fin Pitches with Ceramic Coating

1K. Ranjithkumar

PG student,

CMS College of Engineering, Namakkal, Tamil Nadu, India.

3R. Periyasamy

Assistant Professor,

2 M. Santhoshkumar

Assistant Professor, Mechanical Engineering Department

CMS College of Engineering , Namakkal, Tamil Nadu, India,

Mechanical Engineering Department, Kongunadu College of Engineering and technology , Namakkal, Tamil Nadu, India,

Abstract:- This Project presents the airside performance of fin and tube heat exchangers for multi-louvered plate fin. This project focuses on heat and fluid flow analysis by various fin pitches and angle patterns. A steady state three-dimensional numerical model is used to study the heat transfer and pressure drop characteristics of a multi-louvered plate fin heat exchanger with Reynolds number in the range of 1000-1600.A numerical study is performed on compact fin and tube heat exchanger having circular tube with plate fin vortex generator. The performance of heat exchanger in the air side with coating and without coating of the fin will be analyzed for various pitches such as 2, 2.5, 3, 3.5 mm and 4mm. By varying fin pitches, the overall heat transfer rate will increase in the system. In heat exchanger device the heat transfer analysis will be done by increasing number of tubes, rows, passes, and pitches.

Keywords: Fin Pitch, Pressure drop, Heat Exchanger, Fin Thickness

I . INTRODUCTION

A heat exchanger is a device that is used for transfer of thermal energy (enthalpy) between two or more fluids, between a solid surface and a

fluid, or between solid particulates and a fluid, at differing temperatures and in thermal contact, usually without external heat and work interactions.

Currently, the plate fin-and-tube heat exchanger earns its popularity in waste heat

recovery system applications. This is because of the easy manufacturing process of the plate fin, which is quite common in industrial services. The conventional plate fin is a simple type of the plate fins. The main difference between the conventional plate fin with several plate fin types is that the feature of fin base. The tube surface at the base of conventional multi-louvered plate fin is not covered by the fin, leading to the risk of tube corrosion.

The experimentally investigated the effects of fin pitch and fin outside diameter on the characteristics of heat transfer and pressure drop for serrated multi-louvered finned- tube heat exchangers having staggered tube layouts. It was indicated that the fin pitch increased with increasing heat transfer coefficient at the same Reynolds number. The fin outside diameter, however, had an insignificant effect on the heat transfer coefficient. The multi-louvered plate finned tube heat exchangers have better air-side heat transfer Performance than the plate-finned tubes , because of high vortex shedding frequency.

Plate and fin heat exchangers are mostly used for low temperature services such as natural gas, helium and oxygen liquefaction plants, air separation plants and transport industries such as motor and aircraft engines.

    1. CORRUGATIONS (FINS)

      Corrugations are also made with heat transfer enhancement devices..Plain corrugation is the basic form and is used normally for low pressure drop streams. Perforated corrugation shows a slight increase in performance over plain corrugation, but this is reduced by the loss of area due to perforation. The main use is to permit migration of fluid across fin channels, usually in boiling duties. Serrated corrugation is made by cutting the fins every 3.2 mm and displacing the second fin to a point half way between the preceding fins. This gives a dramatic increase in heat transfer.

      Herringbone corrugation is made by displacing the fins sideways every 9.5 mm to give a zig-zag path. Performance is intermediate between the plain and serrated forms. The friction factor continues to fall at high Reynolds

      14 numbers, unlike the serrated, showing advantages at higher velocities and pressures. The designer can, therefore,

      vary fin heights, fin pitch and fin thickness together with four standard fin types giving great versatility of design.

    2. REASON FOR SELECTION

PLATE FINS

High heat transfer coefficient

High mechanical strength of fin

Increase the heat transfer surface area

CERAMIC COATING

TemperatureRanges

For many years, the only coating able to withstand the high temperatures of many motorcycle parts was chrome. As formulation, ceramic can withstand from 600 to 2000 degrees Fahrenheit. Exhaust pipes, manifolds and headers become hot, and the choices for coating are limited. Ceramic coatings withstand the extensive heat generated by these parts and can lower the temperature of the part. Most ceramic coatings are also smooth and reduce friction when used on engineparts

ColorChoices

Ceramic also allows you to add color other than chrome to your engine and exhaust parts. It has become common to "black out" bikes. Although ceramic does not come in a huge variety of colors, there are still many colors from which to choose. Most ceramic colors come only in 3 to 30 percent gloss. NIC Industries has a line of ceramic that comes in bold red, yellow, blue and purple as well as black, silver and various shades of brown and green, which can withstand approximately 1200 to 2000 degrees Fahrenheit.

Durability

In addition to being heat resistant, ceramic is durable once cured. It is resistant to scratches, impacts and corrosion. Some ceramic coatings are more resistant that others. Special "high humidity" Chromex can withstand up to 3,000 hours in a salt spray test. This test is used in the coating industry to determine durability of powder and ceramic coating. Depending on whether a primer is applied, most air dry or oven cure ceramic coatings can withstand from 350 to 1000 hours in a salt spray test.

SPECIFICATION OF PLATE FIN MODEL

The plate fin arrangements are modeled as per the standard specifications.

DESIGN OF MULTI-LOUVERED PLATE FIN HEAT EXCHANGERS

The plate-fin heat exchanger is made up of layers of corrugated sheets separated by plate metal plates, typically aluminium, to create series of finned chambers. Separate hot and colt fluid streams flow through alternating layers of the heat exchanger and are enclosed at the edges by side bars. Heat is transferred from one stream through the fin interface to the separator plate and through next set of fins into the adjacent fluid. The fins also serve to increase the structural integrity of the heat exchanger and allow it to withstand high pressures while providing an extended surface area for heat transfer. A high degree of flexibility is present in plate-fin heat exchanger design as they can operate with any combination of gas, liquid, and two-phase fluids. Heat transfer between multiple process streams is also accommodated, with a variety of fin diameters and types as different entry and exit points available for each stream.

The main four types of fins are: plain, which refer to simple straight-finned triangular or rectangular designs; herringbone, where the fins are placed sideways to provide a zig-zag path; and serrated and perforated which refer to cuts and perforations in the fins to augment flow distribution and improve heat transfer.

Fig 1.multi louvered plate fin exchanger

III . EXPERIMENTAL SETUP AND PROCEDURE:

MULTI-LOUVERED PLATE FIN

TUBE

Material

Aluminium

Material

Copper

Fin Pitch

3mm

Outer diameter

9.5mm

Fin Thickness

1mm

Inner diameter

6mm

Outer diameter of fin

30mm

Wall Thickness

3.5mm

Inner diameter of fin

9.6mm

No. of row in tube

2

Longitudinal tube pitch

40mm

Transverse tube pitch

31mm

No of Tubes in a row

8

The schematic of the experimental system used in this research is shown in Fig 2. It includes, an electrical heater , a temperature controller ,a digital thermometer. The test section of the heat exchanger tube inlet was connected with electrical heater outlet port and its configuration is the louvered fin-and-tube type. The fins and tubes are made with aluminium and copper tubes. Hot water allow to pass through the exchanger tube inlet. At that same time study the water inlet and outlet temperature of the fin and tube heat exchanger and engine operation timing for numerical analysis. A water inlet and outlet temperatures, engine operation timing shown in Tables 2-5. Experimental readings are taken for different fin pitches with ceramic coating at every 15 min of engine operations upto 60mins.

Table 1.Specification of plate fin model

Fig 2.schematic of experimental setupalternately (unless you really mean something that alternates).

    1. EXPERIMENTAL READING FOR DIFFERENT FIN PITCHES WITH CERAMIC COATING

      Different Inlet And Outlet Temperature At Various Timings

    2. GOVERNING EQUATIONS FOR CALCULATING AIR SIDE HEAT TRANSFER OF MULTI-LOUVERED PLATE FIN AND TUBE HEAT EXCHANGER

      The method of number of transfer units (e-NTU), based on the concept of heat exchanger effectiveness, was applied to determine the UA product.

      The air-side heat transfer rate is given as: Qa= macpaTa———— ( 1 )

      The water-side heat transfer rate is given as

      Qw= mw cpwTw———- ( 2 )

      The total rate of heat transfer used in the calculation is averaged from the air-side and water-side as follows: Qave = [Qa]+[Qw] ——— (3 )

      2

      The overall heat transfer coefficient can be written in terms of the total resistance to heat transfer. This total resistance is the sum of the individual resistances, as follows:

      ln(0

      1 = 1 + ) + 1/ ——–( 4 )

      SL.NO

      Fin Pitch

      Water Inlet Temperature

      Water outlet Temperature

      (mm)

      (ºC)

      (ºC)

      1

      2

      42

      39

      2

      2.5

      42

      37

      3

      3

      42

      33

      4

      3.5

      42

      35

      5

      4

      42

      38

      2

      0 0

      Table 2. For First 15min of engine operation

      Table 3. For 30min of engine operation

    3. EXPERIMENTAL CALCULATION

      TOTAL HEAT TRANSFER RATE (At fin pitch of 2mm)

      Air inlet Temperature = 31ºC , Air outlet Temperature=32.5ºC

      SL.NO

      Fin Pitch

      Water Inlet Temperature

      Water outlet Temperature

      (mm)

      (ºC)

      (ºC)

      1

      2

      46.55

      41

      2

      2.5

      46.55

      38

      3

      3

      46.55

      35

      4

      3.5

      46.55

      39

      5

      4

      46.55

      42

      Water Inlet Temperature=46.55 ºC , Water Outlet Temperature=41ºC Total heat transfer rate = ,

      Mass flow rate of water (m) = 0.18 kg/s Specific heat of water (m) = 4186 J/kgk Total Heat transfer rate (Q)

      = 0.18X4186(46.55-41 )ºC

      =4181.8 W

      Total no of fins = 15 Heat transfer rate of single fin

      SL.NO

      Fin Pitch

      Water Inlet Temperature

      Water outlet Temperature

      (mm)

      (ºC)

      (ºC)

      1

      2

      51

      49

      2

      2.5

      51

      46

      3

      3

      51

      39

      4

      3.5

      51

      42

      5

      4

      51

      46

      = over all heat transfer/15

      = 278.7W

      = ( )

      = 11716

      =

      =4181.8/11716.6

      = 0.356

      Table 4 For 45min of engine operation

      = 0.356

      SL.NO

      Fin Pitch

      Water Inlet Temperature

      Water outlet Temperature

      (mm)

      (ºC)

      (ºC)

      1

      2

      56.5

      51

      2

      2.5

      56.5

      49

      3

      3

      56.5

      44

      4

      3.5

      56.5

      45

      5

      4

      56.5

      46

      TOTAL HEAT TRANSFER RATE (At fin pitch of 2.5mm)

      =0.549

      TOTAL HEAT TRANSFER RATE (At fin pitch of 3mm)

      =0.742

      Table 5 For 60min of engine operation

      TOTAL HEAT TRANSFER RATE (At fin pitch of 3.5mm)

      =0.485

      TOTAL HEAT TRANSFER RATE (At fin pitch of 4mm)

      =0.29

      1. RESULT AND DISCUSSION

        4.1. Effect of fin pitch

        Outlet temperature C

        The study focuses the effect of fin pitches (2, 2.5,3,3.5 and 4), air side performance of multi-louvered plate fins with ceramic coating on 5 tube pass compact fin and

        40

        38

        36

        34

        32

        30

        outlet temperatur e

        2 2.5 3 3.5 4

        Fin Pitch

        Graph 4.1 Outlet temperature Vs fin pitches

        Outlet temperature in

        C

        The graphical representation 4.2 is shown b/w fin pitch and outlet temperature of water at first ½ hour operation of engine

        44

        42

        40

        38

        36

        34

        32

        30

        outlet

        tempoeratu re

        2 2.5 3 3.5 4

        Fin pitch

        Graph 4.2 Outlet temperature Vs fin pitches

        The graphical representation 4.3 is shown between fin pitch and outlet temperature of water at first ¾ hour operation of engine

        Graph 4.3 Outlet temperature Vs fin pitches

        The graphical representation 4.4 between fin pitch and outlet temperature of water at first 1 hour operation of engine

        tube heat exchanger, this type of heat exchangers used in wide applications like automobile radiator economizers, refrigerations.

        The graphical representation 4.1 is shown between fin pitch and outlet temperature of water from first ¼ hour operation of engine

        Graph 4.4 Outlet temperature Vs fin pitches

        Effectiveness

        The graphical representation 4.5 is shown between the fin pitches and effectiveness at engine operation of ½ hour

        0.8

        0.6

        0.4

        0.2

        effectiveness

        0

        2 2.5 3 3.5 4

        Fin pitch

        Graph 4.5 Effectiveness Vs fin pitches

        The graphical representation 4.6 is shown between heat transfer rate per fin and fin pitch

        Graph 4.6 Heat transfer rate Vs fin pitches

        The performance plot for the three configurations investigated is depicted for Reynolds numbers 1000, 1200 and 1600, respectively. It is clear that for the same heat transfer area, the case with multi-louvered plate fins delivers better performances than the case with other fins. The configuration with multi-louvered plate fins shows an about 9% better heat transfer rate for the same power input than the configuration with other fins having the same heat transfer area. The graphical represented of heat transfer rate with respect to fin pitches at different operating time, it shows that the heat transfer rate is higher at fin pitches of

        2.5 and 3.

        The experimental was carried out different fin pitches of 2, 2.5, 3, 3.5,4 from that fin pitches of 2.5,3 gives higher heat transfer rate and fin pitches affect heat transfer rate if fin pitch increases to increase pressure drop. The reduction of fin pitch increase heat transfer if fin pitch reduced more the is restricted to reduce the heat transfer rate.

      2. CONCLUSIONS

The numerical investigation was carried out in this study show the advantage of multi-louvered plate fins in improving the performance of finned tubes or compact fin and tube heat exchanger. This is mainly due to the fact that the interruption of fins in these devices improves the re- build of the boundary layer close to heat transfer surfaces and increases the level of fluid mixing in the flow domain. The fin Pitches 2.5 to 3.5 gives better performance and also gives more heat transfer rate .

The fin effectiveness is maximum at a fin pitch of 2.5,3.

The heat transfer rate per fin is maximum at fin pitch of 2.5,3, So using the multi-louvered plate fin and tube heat exchanger in any applications like radiators etc.. At a fin pitches of 2.5,3 gives higher heat transfer and increase performance of heat exchanger. The results obtained show that for the same heat transfer area, the multi-louvered plate fin tubes have better performances than the full fins. The ceramic coating gives better performance in under wet conditions, there no corrosion on the finned tube when used for number of days in practical Application. It is useful for manufacturing industries and power plants to increase performance in future days.

REFERENCES

A numerical study on the air-side heat transfer of perforated finned-tube heat exchangers with large fin pitches by Xiaoqin Liu, JianlinYu, Gang Yan(International Journal of Heat and Mass Transfer2016)

  1. Numerical study of heat-transfer enhancement by punched winglet-type vortex generator arrays in fin-and-tube heat exchangers by Y.L. He a, H. Han a*, W.Q. Tao a, Y.W. Zhang ab (International Journal of Heat and Mass Transfer 2012)

  2. Numerical investigation of fluid flow and heat transfer over louvered fins in compact heat exchanger by V.P.Malapure, Sushanta K. Mitra,A. Bhattacharya (International Journal of Thermal Sciences 2015)

  3. Optimization of the angle of attack of delta-winglet vortex generators

  4. in a plate-fin-and-tube heat exchanger by A. Lemoueddaab, M. Breuer c, E. Franz a*,T. Botscha, A. Delgado b (International Journal of Heat and Mass Transfer 2010)

  5. Experimental and numerical investigation of the heat transfer augmentation and pressure drop in simple, dimpled and perforated dimpled louver fin banks with an in-line or staggered arrangement by FarhadSangtarash*, HosseinShokuhmand ( International Applied Thermal Engineering 2015)

  6. Numerical study of fluid flow and heat transfer in a flat-plate channel with longitudinal vortex generators by applying field synergy principle analysis by Li-Ting Tian, Ya-Ling He*, Yong- Gang Lei, Wen-Quan Tao ( International Communications in Heat and Mass Transfer 2008)

  7. Heat and mass transfer for plate fin-and-tube heat exchangers, with and without hydrophilic coating by Chi-Chuan Wang a,*: Chang-Tsair Chang b (International Journal of Heat and MassTransfer 2008)

  8. An experimental study of the air-side performance of fin-and-tube heat exchangers having plain, louver, and semi-dimple vortex generator configuration by Chi-Chuan Wang a* , Kuan-Yu Chen a, Jane-SunnLiawbChih-Yung Tseng b (International Journal of Heat and Mass Transfer 2014)

  9. Application Research on the Closed-Loop Heat-source-Tower Heat Pump Air Conditioning System in Hot-summer and Cold- winter Zone by JianlinChenga, ShenhuaZoua, and Shiqiang Chena (International journal on energy engineering, 2015)

  10. An experimental study on performance during reverse cycle defrosting of an air source heat pump with a horizontal three circuit outdoor coilgions. By Song Mengjiea, XuXiangguob, Deng Shiminga, Mao Ning International journal on energy engineering, 2014)

  11. A Numerical Investigation of Compact Spiral Fin Heat Exchanger for Circular Tubes with Hydrophilic Coating by P.Rajkumar1 M. Ganesh karthikeyan2 Dr.M.Prabhakar3 S.Senthil Kumar4 (IJSRD – International Journal for Scientific Research & Development 2016)

Leave a Reply