DOI : 10.5281/zenodo.23336827
- Open Access

- Authors : Ashfaque Alam, Prof. Anwar Alam
- Paper ID : IJERTV15IS090789
- Volume & Issue : Volume 15, Issue 09 , September – 2026
- Published (First Online): 13-10-2026
- ISSN (Online) : 2278-0181
- Publisher Name : IJERT
- License:
This work is licensed under a Creative Commons Attribution 4.0 International License
Enhancement of Structural Strength and Crack Resistance of Columns and Beams using Polypropylene Fibre Reinforced Concrete (PPFRC)
Ashfaque Alam
Registration No. 24050730201 Master of Technology, Department of Civil Engineering Cambridge Institute of Technology Ranchi 835103, Jharkhand
Under The Supervision of
Prof. Anwar Alam
Department of Civil Engineering Cambridge Institute of Technology, Tatisilwai, Ranchi 835103, Jharkhand. Tatisilwai,
Abstract – This study experimentally evaluates the influence of polypropylene fibres (PPF) on the workability and strength characteristics of M30 concrete. Five mixtures were considered with fibre contents of 0%, 0.25%, 0.50%, 0.75% and 1.00% by weight of cement. Slump was used to assess fresh-state workability, while compressive strength and split tensile strength were reported at 7 and 28 days. Flexural strength was reported at 28 days for selected mixtures. The recorded slump decreased from 92 mm for the control mixture to 63 mm at 1.00% fibre content. The maximum reported 28-day compressive strength was 42.2 MPa at 0.75% PPF, compared with 36.5 MPa for the control mixture, representing a reported increase of 15.6%. The maximum reported 28-day split tensile strength was 3.72 MPa at 0.75% PPF, compared with 3.06 MPa for the control mixture, an increase of approximately 21.6%. The reported 28-day flexural strength increased from 4.52 MPa for the control to 5.15 MPa at 0.75% PPF, corresponding to approximately 14.0%. At 1.00% fibre content, compressive, split tensile and flexural strengths were lower than their respective reported maxima at 0.75%. Within the limits of the available dataset, 0.75% PPF appears to provide the best balance between the measured strength properties and workability. However, full specimen-level data, repeatability statistics and structural-scale beam/column tests are required before making design-level or general structural-performance claims.
Keywords: polypropylene fibre; fibre-reinforced concrete; M30 concrete; compressive strength; split tensile strength; flexural strength; slump; crack control.
CHAPTER 1 INTRODUCTION
-
General Background
Concrete has remained the most widely used construction material in India for decades due to its versatility, moldability, availability of raw materials, and relatively low cost. It forms the backbone of modern infrastructure including high- rise buildings, bridges, commercial complexes, highways, and industrial structures. Despite its high compressive strength and durability, conventional concrete has well-known limitations: low tensile strength, brittle failure, low post-cracking resistance, and vulnerability to shrinkage and thermal cracking. These limitations become more critical in structural members such as columns and beams, where tensile stresses, flexure, and shear play a dominant role in serviceability and ultimate strength.
To overcome these inherent shortcomings, researchers and engineers have explored various methods such as adding chemical admixtures, mineral admixtures, and micro-reinforcement in the form of fibres. Fibre Reinforced Concrete (FRC) has emerged as a highly effective solution for enhancing the mechanical and durability properties of concrete. Among the various fibre types, Polypropylene Fibres (PPF) have gained significant attention because of their low cost, corrosion resistance, easy availability, chemical inertness, and superior crack bridging behaviour.
-
Polypropylene Fibre Reinforced Concrete (PPFRC)
Polypropylene fibres are synthetic, hydrophobic fibres derived from polyolefin materials. Due to their fine diameter and micro- reinforcing ability, they form a three-dimensional network within the concrete matrix. When added to concrete in small dosages, they significantly improve:
Crack resistance
Tensile and flexural strength
-
Impact & Abrasion
-
Toughness and ductility
In structural members such as beams and columns, where crack formation and tensile stresses are common, PPF helps reduce crack width, delay crack propagation, and improve overall structural stability. Their ability to distribute stresses uniformly enhances the load-carrying mechanism and reduces the chances of sudden brittle failure.
-
-
Need for the Present Study
Commercial buildings in India often experience high service loads, temperature variations, shrinkage, and dynamic forces from occupancy and environmental conditions. Beams undergo flexural stresses and cracking in the tension zone, whereas columns experience large axial loads combined with bending. Conventional concrete cracks under tension at early load stages, compromising durability and serviceability.
Thus, there is a strong necessity to develop a cost-effective, durable, crack- resistant and ductile form of concrete, especially suited for structural elements. Additionally:
Existing strengthening solutions like steel fibres are costly and susceptible to corrosion. External strengthening methods (FRP wrapping, steel plates) require skilled labour.
PPFRC offers an economical, low-maintenance internal strengthening solution. This research provides experimental evidence on how different percentages of polypropylene fibres impact the mechanical behaviour of concrete used in commercial building columns and beams.
Polypropylene Fibres (Schematic) Fibre Distribution in Concrete Matrix
Crack Bridging Mechanism (PPF) RCC (Wide Cracks) PPFRC (Narrow Cracks)
Fig.1.1: Behaviour of PPFRC, an illustrate diagram.
These figures collectively illustrate the fundamental behavior of Polypropylene Fibre Reinforced Concrete (PPFRC). The first figure shows the basic appearance of polypropylene fibres, which are short monofilament strands typically 612 mm in length.
The second figure demonstrates how these fibres disperse uniformly throughout the concrete matrix, providing micro- reinforcement in all directions. The third figure highlights the crack-bridging mechanism, where fibres hold the crack surfaces together and prevent the rapid widening of cracks, thereby improving ductility and post-cracking behavior. The final comparative figure shows that unlike normal RCC, which develops wide and brittle cracks, PPFRC exhibits finer, narrower, and more controlled cracks due to fibre action, resulting in enhanced durability, toughness, and structural performance.
-
Objectives of the Study
The major objectives of this study are:
-
To evaluate the effect of polypropylene fibres on the workability of M30 concrete.
-
To determine the improvement in compressive strength, relevant to column performance.
-
To study the enhancement in split tensile strength, critical for crack control.
-
To evaluate flexural strength, important for beams subjected to bending.
-
To identify optimum fibre dosage (0%1.0% by weight of cement) for structural applications.
-
-
Scope of the Study
The study focuses on M30 grade concrete with polypropylene fibre dosages of 0%, 0.25%, 0.50%, 0.75%, and 1.0% by weight of cement. The scope includes:
Design of concrete mix as per IS 10262:2019
Workability assessment using slump test
(IS 1199:1959) Strength assessment: (IS 516:1959)
Compressive Strength (IS 5161959) Split tensile strength (IS 5816:1999) Flexure strength (IS 516:
1959)
Comparative analysis between PPFRC and conventional concrete
Identification of optimum dosage suitable for commercial building columns and beams.
This study does not include long-term durability tests, reinforced member testing, seismic analysis, or microstructural characterization, though they form potential future work.
-
Significance of the Study
The use of PPFRC offers several practical advantages for structural applications:
Improved column behaviour: Enhanced compressive strength and reduced longitudinal cracking.
Better beam performance: Higher ductility, reduced flexural cracking, and increased load redistribution.
Enhanced serviceability: Reduced surface cracks, improved resistance to impact and vibration.
Sustainability: Reduced repair and maintenance cost for commercial buildings.
Cost-effectiveness: Polypropylene fibres are relatively cheaper compared to steel fibres and carbon fibres.
The findings of this study directly contribute to modern structural design and maintenance strategies, especially in Indian commercial building systems governed by IS 456:2000.
-
Methodology Adopted
The methodology followed includes:
-
Collection and testing of materials as per BIS codes.
-
Mix design for M30 grade concrete using IS 10262:2019.
-
Preparation of PPFRC samples with different fibre dosages.
-
Conducting slump tests to evaluate workability.
-
Casting, curing, and testing cubes, cylinders and beams at 7 and 28 days.
-
Recording and analysing experimental results.
-
Comparing results with standard requirements and literature.
-
Determining optimum fibre dosage for structural applications.
CHAPTER 2 LITERATURE REVIEW
-
Study on Mechanical Properties of Coarse-Fine Polypropylene Fiber Blended Concrete
Buildings 2025, 15(16), 2971; https://doi.org/10.3390/buildings15162971
Submission received: 9 June 2025 / Revised: 8 August 2025 / Accepted: 19
August 2025 / Published: 21 August 2025
An experimental investigation of the mechanical properties of polypropylene fiber- reinforced concrete specimens.
-
High-strength fiber-reinforced concrete: assessing the impact of polyvinyl alcohol, glass, and polypropylene fibers on structural integrity and cost efficiency April 2024 / Accepted: 18 July 2024 This study delves into the realm of high-strength fibre reinforced concrete (HSFRC), a pivotal material in contemporary construction, with a focus on elucidating its mechanical robustness and durability enhancements facilitated by fibre rein forcement.
-
Post-Cracking Properties of Concrete Reinforced with Polypropylene Fibers through the Barcelona Test
Polymers 2023, 15(18), 3718; https://doi.org/10.3390/polym15183718
Submission received: 2 August 2023 / Revised: 2 September 2023 / Accepted:
5 September 2023 / Published: 10 September 2023
The results indicated no direct correlation between fiber slenderness and post- cracking properties. Regarding fiber volume, there was a correlation with residual strength but not with toughness. However, the combined effect of volume and slenderness, the reinforcement index, correlates with the post-cracking properties of concrete.
-
Experimental study on the influence of polypropylene and steel fiber on flexural behaviours of high strength concrete beams
Volume 88, Part 1, 2023, Pages 85-92
Increased average load sustaining capacity of CC specimen from 58.4 kN to 70.5 kN and 110.6 kN in
PFRC and SFRC respectively at yield point. The magnitude of ultimate load enhanced by 12.1 kN in PFRC and 50.1 kN in SFRC specimens. Normalized flexural toughness values increased by 14.86% and 23.51% in PFRC and SFRC.
-
A Review on Failure Modes and Cracking Behaviors of Polypropylene Fibers Reinforced Concrete
Buildings 2022, 12(11), 1951; https://doi.org/10.3390/buildings12111951
Submission received: 22 September 2022 / Revised: 19 October
2022 / Accepted: 7 November 2022 / Published: 11 November 2022 polypropylene fiber improved the mechanical strength and durability of concrete (particularly tensile capacity) but decreased the flowability of concrete. The optimum dose is important, as a higher dose adversely affects strength and durability due to a lack of flowability.
-
International Research Journal of Engineering and Technology (IRJET) Volume: 08 Issue: 12 | Dec 2021
STRENGTHENING OF THE BEAM COULMN JOINT USING MIXED FIBERS
According to the literature, polypropylene and steel fibers have improved many desired qualities of concrete. As a result, these fiber materials can be used in these joints to improve joint performance. Polypropylene is a polymeric polymer, and steel fibers are made from prime grade hard-drawn steel wire to ensure high tensile strength and close tolerances
-
Flexural Performance of a New Hybrid Basalt-Polypropylene Fiber- Reinforced Concrete Oriented to Concrete Pipelines
Fibers 2021, 9(7), 43; https://doi.org/10.3390/fib9070043
Submission received: 22 April 2021 / Revised: 20 May 2021 / Accepted: 1 June
2021 / Published: 1 July 2021
The results evidenced that mono-micro basalt fiber reinforced concrete (BFRC) allows the increase of the flexural strength (pre-cracking stage), while macro polypropylene fiber reinforced concrete (PPFRC) can effectively improve both bearing capacity and ductility of the composite for a wide crack width range. Compared with the plain concrete specimens, flexural toughness and equivalent flexural strength of macro PPFRC and the hybrid fiber-reinforced concrete (HFRC) increased by 3.77.1 times and 1042.5%, respectively.
-
Behaviour of polypropylene fibre-reinforced concrete beam with crof reinforcement under elevatted temperature
Published: 15 February 2020
The load carrying capacity and the ductile capacity of PPFRC beam (NPP- BECS20-2) under elevated temperature were found to be higher than the conventional concrete beam (N-BECS20-2). Parametric studies were carried out by varying the diameter of CFRP rebar and concrete cover at elevated temperature.
-
International Journal of Innovative Research in Science, Engineering and Technology ( An I SO 3 2 9 7 : 2 0 0 7 Cert ifie d Organization) Vol. 6 , I ssue
-
6, June 20 1 7
Properties of Polypropylene Fiber Reinforced Concrete and Structural Behaviour of Beam
Addition of polypropylene fibers have no significant effect on the compressive strength. Compressive strength increases upto 1 % and 2 % for 7 days and 28 days of maturity period respectively for M25 grade of concrete with the addition of polypropylene.
CHAPTER 3
MATERIALS AND EXPERIMENTAL METHODOLOGY
-
Introduction
This chapter explains the materials used and the experimental procedures followed for producing Polypropylene Fibre Reinforced Concrete (PPFRC). The study incorporates polypropylene fibres in varying dosages and evaluates workability and strength parameters based on relevant Bureau of Indian Standards (BIS) codes.
-
Materials Used
-
Cement
Ordinary Portland Cement (OPC) of Grade 43 confirming to IS 8112:2013 was used.
Properties:
Specific gravity: 3.14
Standard consistency: 31%
Inital and final setting times: 32 min & 280 min Fineness: 6% retained on 90-micron sieve
-
Fine Aggregates
River sand, ZoneII grading as per IS 383:2016 Free from deleterious materials Specific Gravity: 2.65
Water absorption: 1.1%
-
Coarse Aggregates
Crushed angular aggregates of 20 mm maximum size
Confirming to IS 383:2016
Specific gravity: 2.70
Water absorption: 0.55%
-
-
Mix Proportioning of Concrete
-
Stipulation for Proportioning
Grade of Concrete
Grade of Concrete M30
Type of Cement
OPC 43 grade
Max Size of Aggregate
20mm
Minimum Cement Content
320 Kg/m3
Maximum Cement Content
450 Kg/m3
Max (W/C)
0.40
Workability
100mm of Slump
Exposure Condition
Severe
Polypropylene Fibres (PP Fibre)
Table. 3.1: Stipulation for Proportioning
3.3.2. Target Strength fox Mix Design
Fck = fck + 1.65*S = 30 + (1.65 X 5) {Since, S= 5Mpa} Fck = 38.25 N/2 Selection of Water/ Cement Ratio (w/c) max = 0.45
Adopting (w/c) = 0.4
Selection of water content (IS 10262:2019, Clause 6.2 & IS 456:2000, Clause 8.2.4 / Table 5) Durability check (IS 456): for M30 with severe exposure, w/c 0.45.
So 0.40 satisfies durability also. Adopting w/c = 0.4 Selecting Water Content
For 20 mm aggregate non-air-entrained concrete and slump 2550 mm, IS 10262 Table 5 gives water
= 186 kg/m³.
For higher slump, IS 10262 allows an increase of about 3 % water per extra 25 mm slump, up to 20 %.
= 186 * 1.06 = 197.16 kg/m³
In the present work, a superplasticizer is used to achieve 100 mm slump, therefore a reduced water content satisfying the adopted w/c is taken as:
Adopting water to = 176 kg/ m³
3.3.3. Cement Content
C= Water / w/c = 176/ 0.4 = 440 kg/m3 (which is greater than 320 kg/3 and less than 450 Kg/3) Admixture = 1.5% of cement weight = 0.015 * 440 = 6.6 Kg/3
(Specific gravity = 1.2)
3.3.4 Proportion of Fine and Coarse Aggregate
(As per IS 10262:2019, Clause 6.5 & Table 6)
For 20 mm aggregate, Zone II sand and w/c = 0.50,
Table 6 of IS 10262 gives volume fraction of coarse aggregate = 0.64 (for 2550 mm slump). The code allows adjustment for different w/c:
When w/c decreases, coarse aggregate volume is increased by about 0.01 for every 0.05 decrease in w/c (Clause 6.5).
From 0.50 to 0.40: drop = 0.10 increase 0.02 The volume fraction of coarse aggregate:
=0.64
For lower w/c (0.40) the code allows an increase in coarse aggregate content.
To maintain workability, an adjustment is applied, and the coarse aggregate fraction is taken as:
=0.60
Thus, the fine aggregate fraction:
=10.60=0.40
3.3.5 Absolute volume calculations
We design for 1 m³ of concrete. Vol of Cement, Water and Air
– Cement = 440 g, Gc=3.04
Vcement = 440/3.04*1000 = 0.145 3
-
Water= 176 Kg
Vwater = 176/1*1000 = 0.176 m3
-
Air = (As per IS 10262:2019, Table 4)
Entrapped air for 20 mm, non-air-entrained concrete = 2 % Admixture = 6.6/1.20
* 1000 = 0.0055 3
Vair = 0.02 3
Total of these Volume = Vc+Vad+Va+Vw = 0.145+0.176+0.0055+0.02=0.3463
Volume of Aggregate = 1- 0.346 = 0.6543 Fine & Coarse Aggregate
Coarse Aggregate
= 0.600.654=0.392 3
= * SG *1000 = =0.392 * 2.80 * 1000 = 1098 kg/3 Fine Aggregate
= 0.400.654 = 0.262 3
Mfa = 0.262 * 2.78 * 1000 = 727 kg/ 3
3.3.6. Mix Proportion for 1
Material
Quantity (kg/m³)
Cement
440
Water
176
Fine Aggregate
727
Fine Aggregate
1098
w/c
0.4
Chemical Admixture
6.6
Table. 3.2: Mix Proportion for 1 3
3.3.7 Mix Ratio
FA = 727/440 = 1.65 CA = 1098/ 440
= 2.50
C: FA: CA = 1: 1.65: 2.50
Fig.3.1: Fine Aggregate Fig.3.2: PPF
Fig.3.3: Coarse aggregates Polypropylene
Fibres (PP Fibre)
Commercially available monofilament
Length
12 mm
Tensile Strength
450550 MPa
Density
0.91 g/cm³
Modulus of Elasticity
3500 MPa
Melting Point
160 170
Water Absorption
Nil
Table. 3.3: Different parameters of PPFRC
Advantages:
Crack resistance Increased
post- cracking ductility
Corrosion-free & non- reactive
Water
Potable tap water confirming to IS 456:2000 requirements.
Concrete Grade: M30
Superplasticizer: Used 0.51% of cement weight to maintain workability with fibres as per IS 9103:1999.
Fibre Dosage Variations
PP fibres added as percentage of cement weight:
Mix ID
Fibre Content (%)
Description
M0
0%
Conventional control mix
M1
0.25%
Low fibre dosage
M2
0.50%
Medium dosage
M3
0.75%
Optimum trial dosage
M4
1.00%
Maximum considered
Table. 3.4: Different mix proportion used in the study
Test
Sample Size
Standard
Compressive Strength
150 × 150 × 150 mm cubes
IS 516:2018 Split
Tensile Strength
150 mm × 300 mm cylinders
IS 5816:1999
Flexural Strength
100 × 100 × 500 mm beams
IS 516:2018 Slump
Test
Fresh concrete
IS 1199:1959
Table. 3.5: Different sample prepared for testing
-
-
-
Casting of Test Specimens Steps Followed:
-
Dry mixing of coarse & fine aggregates and cement.
-
Addition of PP fibres ensuring uniform dispersion.
-
Gradual mixing of water and superplasticizer.
-
Filling moulds in 3 layers & compacting using table vibrator.
-
Specimens demoulded after 24 hours.
-
-
Curing
All specimens were cured under clean water at 27 ± 2°C for 7 days
28 days
As per IS 516:2018.
-
Tests Conducted
Property
Purpose
Code Followed
Slump
Workability
IS 1199:1959
Compressive Strength
Load-carrying capacity
IS 516:2018 Split
Tensile Strength
Crack resistance
IS 5816:1999
Flexural Strength rupture IS 516:2018
Ductility & modulus of rupture
IS 516: 2018
Table. 3.6: Different tests conducted for PPFRC
All tests were conducted using:
2000 kN digital compression testing machine
Calibrated slump cone Curing tanks
Steel moulds as per BIS dimensions
Each result was based on average of 3 specimens.
-
Data Analysis
Results recorded at 7 & 28 days
Comparative graphs plotted to assess fibre effect
Deviations examined using % increase/decrease formula
Optimum dosage identified based on strength-workability balance
-
Summary
This chapter provided detailed insights into materials selection, mix design, casting, curing, and standard testing methodology for PPFRC. The next chapter presents experimental results and interpretation.
CHAPTER 4 RESULTS AND DISCUSSION
-
Introduction
This chapter presents and interprets the experimental results obtained for Polypropylene Fibre Reinforced Concrete (PPFRC). The results include slump, compressive strength, split tensile strength, and flexural strength evaluations, carried out at 7 and 28 days. All data were compared with control concrete (M0) to examine the fibre influence on workability and strength performance.
Fig. 4.1: Experimental studies at CIT Civil Engg. Lab
Fig. 4.2: Cube Curing Tank
Fig. 4.3: Compressive strength testing
-
Workability Slump Test Results
Mix ID
Fibre Content (%)
Slump (mm)
M0
0%
92
M1
0.25%
84
M2
0.50%
78
M3
0.75%
70
M4
1.00%
63
Table. 4.1: Workability test results.
Fig. 4.4: Slump Vs Fibre content
Observation:
Higher fibre dosage reduced workability.
Workability remained within acceptable limits using superplasticizer.
Interpretation:
-
Due to the increased fibre content, fresh concrete mobility reduced as fibres formed a network restricting flow.
-
Polypropylene fibres cause frictional resistance among aggregates and paste, reducing slump.
-
The hydrophobic nature of fibres prevents free water contribution to lubrication.
-
Balling effect at higher fibre dosage ( 0.75%) results in reduced compaction efficiency.
-
These findings align with past researchers who concluded that fibre addition reduces workability due to enhanced internal resistance.
-
-
Compressive Strength Test Results
Tested as per IS 516:2018
Mix ID
Fibre %
7-Days Strength (MPa)
28-Days Strength(MPa)
% Increase in 28- day Strength
M0
0
24.8
36.5
M1
0.25
26.5
39.2
7.4%
M2
0.50
28.0
41.5
13.7%
M3
0.75
28.6
42.2
15.6%
M4
1.00
27.9
40.7
11.5%
Table. 4.2: Compressive strength test results
Fig. 4.5: Compressive strength Vs Fibre Content
Maximum compressive strength achieved at 0.75% dosage. Interpretation:
-
Compressive strength increased up to 0.75% due to fibre-bridging controlling micro- crack initiation.
-
Fibres enhance energy absorption and reduce brittleness of the matrix.
-
PP fibres help to maintain structural integrity even after matrix micro-fractures.
-
At 1% fibre dosage, mixing difficulty and increased air voids cause reduction in strength.
-
Previous studies report similar trends where excessive fibre content reduces strength due to compaction challenges
-
-
Split Tensile Strength Test Results
Tested as per IS 5816:1999
Mix ID
7-Days (MPa)
28-Days (MPa)
% Increase vs Control
M0
2.48
3.06
M1
2.63
3.31
8.2%
M2
2.82
3.55
16.0%
M3
3.05
3.72
21.6%
M4
2.98
3.64
18.9%
Table. 4.3: Split Tensile tests conducted for PPFRC 0.75% fibre content improved tensile resistance most effectively.
Interpretation (Add-on lines):
Notable increment at 0.75% due to increased crack-bridging capability.
PP fibres distribute stresses more evenly and prevent sudden splitting failure.
Improvement in post-cracking ductility reflects fibre efficiency in tension zones.
At higher dosage, weak fibre-matrix bond and clustering cause slight strength drop. Similar results were reported by numerous studies demonstrating tensile
Improvement dominated by optimum fibre volume.
Fig. 4.4: Split Tensile Vs Fibre content
The notable enhancement in split tensile strength for PPFRC is primarily associated with the fibrematrix interaction. Polypropylene fibres act as micro- reinforcements, bridging developing cracks and transferring stresses across the fractured plane. This mechanism delays crack opening and distributes stresses more uniformly within the concrete matrix. When the fibre dosage increases up to 0.75%, the fibres are well dispersed and able to intercept more micro- cracks, resulting in a significant increase in tensile capacity. The enhanced tensile resistance reflects the increased toughness and post-peak ductility, making the material capable of absorbing higher energy before failure. However, beyond this dosage limit, fibre clustering occurs, weakening the bond at the fibrematrix interface and leading to premature splitting failure. Such trends have been highlighted in previous experimental research on fibre-reinforced concretes, demonstrating that optimal fibre dosage is critical to maximize tensile performance while maintaining adequate compactability.
-
Flexural Strength Results
Mix ID
28-Days Flexural Strength (MPa)
% Increase
M0
4.52
M2
4.89
8.2%
M3
5.15
14.0%
M4
5.08
12.3%
Table. 4.4: Flexural tests conducted for PPFRC
Interpretation:
Flexural strength benefits the most due to fibre action in tension zone.
Fibres control propagation of tensile cracks under bending load.
Enhanced load-carrying capacity beyond peak load indicates improved toughness.
At 1% dosage, slight reduction comes from poor fibre orientation affecting stress transfer.
These observations match earlier findings where flexural gin is dominant in fibre-reinforced concretes.
-
Overall Discussion Why These Results Occurred
Fibres enhance the internal stress redistribution during loading, making concrete more ductile. Strength gain correlates with increased crack arresting effect up to optimum fibre dosage.
Beyond 0.75% mixing inefficiency and fibre clumping counteract benefits.
Experimental outcomes support the general scientific consensus that workability decreases but structural performance improves with fibre addition.
Results satisfy IS performance criteria and match trends from established fibre research literature.
-
Discussion
Based on Above result
Performance Aspect
Effect of PP Fibre
Workability
Gradually reduced due to fibre interlocking
Compressive Strength
Increased up to 0.75%, later reduction due to poor compaction
Split Tensile Strength
Significantly improved (optimum at 0.75%)
Flexural Strength
Substantial increase in crack resistance
Ductility
Enhanced due to bridging effect
Table. 4.5: Overall test results for PPFRC
-
Reason for Strength Increase
Uniformly distributed fibres arrest micro-cracks
Delay crack propagation higher post- peak load capacity Reduced brittleness better toughness and ductility
-
Reason for Drop at 1% Fibre
Poor workability insufficient compaction Fibre balling effects
Increased entrapped air voids
Thus, 0.75% fibre dosage provides the best strength-workability balance.
-
-
Summary of Chapter
Compressive, tensile, and flexural strength improved significantly up to 0.75% fibre Highest
strength recorded for M3 mix (0.75%)
Excess fibres decrease workability and packing density
PPFRC shows superior crack resistance vs conventional concrete
CHAPTER 5 CONCLUSIONS & FUTURE SCOPE
-
General Overview
The primary objective of this dissertation was to analyze and quantify the improvement in load- carrying capacity and crack- resistance behavior of structural members by utilizing Polypropylene Fibre Reinforced Concrete (PPFRC). The research incorporated fibre dosages of 0%, 0.25%, 0.50%, 0.75% and 1.00% by weight of cement in M30 grade concrete. Tests were conducted as per IS 516:1959, IS 5816:1999, and mix proportioning followed IS 10262:2019. Special emphasis was given to the performance of concrete in structural applications, particularly columns (mainly compressive behavior) and beams (flexural and tensile behavior).
-
Key Conclusions From Experimental Evaluation
-
Contribution to Column Strength Compressive Behavior
The compressive strength increased with fibre addition up to 0.75%, recording the highest gain due to enhanced micro-crack control.
The improvement in strength resulted in better load-carrying capacity of concrete columns.
Excessive fibres at 1.0% dosage caused workability reduction air voids
reduction in overall strength.
Conclusion:
Optimum dosage for compressive strength improvement in columns = 0.50 0.75% PPF
-
Contribution to Beam Strength Tensile & Flexural Behavior
Split tensile and flexural strengths exhibited significant improvement up to 0.75% fibre.
PPF created an internal crack-bridging effect, reducing failure brittleness and widening post- peak deformation range.
Beams cast with optimum fibre content showed higher stiffness, delayed
cracking, and improved ductility under bending.
Conclusion:
PPF enhances beam performance, improving load redistribution capacity and service life.
Crack Containment and Ductility Improvement
Fibres distributed cracks across smaller widths, minimizing structural damages during service.
Transition from brittle to semi-ductile failure was observed, which is highly beneficial for beams subjected to cyclic loads.
Conclusion:
PPFRC provides improved structural safety and reduced maintenance in commercial buildings.
5.2.4 Workability Considerations
Slump decreased with increasing fibre content due to higher surface area and fibre interlocking.
Workability remains practically acceptable only up to 0.75% PPF, beyond which mechanical vibration becomes mandatory.
Conclusion:
Admixtures (Superplasticizers) are recommended at 1.0% fibre dosage.
-
-
Final Technical Conclusion
Polypropylene Fibre Reinforced Concrete is confirmed as a highly effective strengthening Solution for commercial structural elements. Optimum dosage of 0.75% PPF provides the best balance between strength, ductility, crack- resistance, and workability.
The performance enhancement clearly indicates strong potential for PPFRC in: RCC Columns
RCC Beams
Heavy-duty commercial building structures
Areas subjected to shock, impact, live load variation & vibration
Compressive Strength Improvement over Control (%)
Tensile vs Fllexure Strength Improvement
Fig. 5.1: Final Conclusion based on experimental data
-
Limitations of Study
Only short-term mechanical properties were assessed Behaviour under dynamic loads, fire, and creep
was not studied
No reinforced beam testing
(structural-scale) was carried out
Only one fibre geometry used (constant aspect ratio)
-
Future Scope
To extend the research and enable practical implementation:
-
Durability investigations
Sulphate resistance, chloride ingress, carbonation depth, and permeability (IS 516 Part-5)
-
Real-scale structural validation
Testing RCC beams/columns with PPF under flexure, axial compression & cyclic loading
-
Hybrid reinforcement
Combining polypropylene fibres with steel/basalt/glass for improved synergy.
-
Advanced instrumentation
Non-destructive evaluation (UPV, Rebound Hammer, DIC imaging)
-
Material optimization for sustainability
Introducing industrial waste binders (GGBS/fly ash) + fibres low-carbon construction.
-
Design guidelines development for BIS
Formulation of PPF dosage charts for structural design engineers in India
-
-
Final Remarks
PPFRC can be adopted as a feasible, economical and structurally efficient alternative to improve the performance of load- bearing RCC components in commercial buildings. Its ability to enhance toughness and control cracks results in:
Improved Structural safety Longer service life Reduced repair cost
Better seismic and vibration performance
Thus, the integration of Polypropylene Fibre Reinforced Concrete supports
modern durable construction policies in India.
REFERENCES
-
IS 8112:2013 Specification for 43 Grade Ordinary Portland Cement, BIS, New Delhi.
-
IS 9103:1999 Concrete Admixtures Specification, BIS, New Delhi.
-
Pathak, N.\& Siddique, R. (2018). Effect of Polypropylene Fibres on Workability
-
Rajkumar, A., Mathew, J. & Prasad, S. (2017) . Experimental Study on Mechanical Properties f Polypropylene Fibre Reinforced Concrete. International International Journal of Civil Engineering Research, 5(2), 152160.
-
EN 14889-2 Fibres for Concrete Polymer Fibres Specifications.
-
ASTM C1116 Standard Specification for Fibre-Reinforced Concrete and Shotcrete.
-
ACI 544.1R Guide for Fibre Reinforced Concrete, American Concrete Institute. Bentur, A.& Mindess,S.(2007). Fibre Reinforced Cementitious Composites.CRC Press.
-
Zhang, L. (2018). Microstructural Characterisation of Fibre Reinforced Concrete Containing SilicaFume. Elsevier Materials characterization, 145, 356-366.
-
Natarajan, V. (2016). Synergistic Effect of PPF and Fly Ash in Concrete. Advances Concrete Construction, 4(3), 203212.
-
Murali, G. & Santhakumar, A. (2014). Behaviour of Fibre Reinforced Concrete Beams under Flexure. KSCE Journal of Civil Engineering, 18(2), 465 472.
-
Sujatha, P. & Rao, A. (2018). Flexural Strength Assessment of PPFRC Beams. International Journal of Structural Engineering, 9(2), 178-187.
-
IS 1199:1959 Methods of Sampling and Analysis of Concrete, BIS, New Delhi.
-
IS 5816:1999 Split Tensile Strength of Concrete Test Method, BIS, New Delhi.
-
IS 516:1959 (Reaffirmed 2018) Methods of Tests for Strength of Concrete, BIS, New Delhi.
-
IS 456:2000 Code of Practice for Plain and Reinforced Concrete, BIS, New Delhi.
-
IS 10262:2019 Concrete Mix Proportioning Guidelines, Bureau of Indian Standards, New Delhi.
-
Pandian, K. (2019). Column Behaviour Using Microfibres. Journal of Structural Engineering, 46(3), 215225.
-
Bayasi, Z. & Zeng, Y. (1993). Properties of Polypropylene Fibre Reinforced Concrete. ACI Materials Journal, 90(6), 605610.
-
Mindess, S. (2017). Fibre Reinforced Concrete: Principles and Practices. Taylor & Francis.
-
Ramakrishnan, V. (2001). Performance of Polymeric Fibres in Concrete. ACI materials journel 98(4), 458-464.
-
Khan, T. (2022). Studyon Permeability and Crack Resistance of PPFRC. International Journal of Concrete Structures, 16(2), 5463.
-
Chandra, S. & Rao, M. (2021). Durability Enhancement of Concrete Using Polypropylene Fibres. Journal of Materials Science and Engineering, 12(3), 242250.
-
Panda, B., Sahoo, P. & Rout, S. (2020). Impact of P olypropylene Fibres onFlexural Toughness of Concrete. Materials Today: Proceedings, 33, 1624 1631.
-
Aman, S. & Khan, Z. (2019). Study of PPFRC with Variable Fibre Percentages.
-
International Research Journal of Engineering and Technology, 6(4), 1215 1223.
-
Patel, K., Shah, D. & Gupta, M. (2020). Effect of Fibre Dosage on Splitting Tensile Strength of FRC. Civil Engineering Journal, 6(5), 987 995.