Effective Positioning of Outrigger in Non- Orthogonal Rcc High-Rise Building under Wind Loading for Different Seismic Zones and Soil Conditions using Etabs

DOI : 10.5281/zenodo.23909346
Download Full-Text PDF Cite this Publication

Text Only Version

Effective Positioning of Outrigger in Non- Orthogonal Rcc High-Rise Building under Wind Loading for Different Seismic Zones and Soil Conditions using Etabs

Vivek A. Sali

M.E Research Scholar, Department of civil engineering Ajeenkya Dy Patil school of Engineering and Technology, Pune, India

Prof. Jitendra Dalvi

Department of civil engineering, Ajeenkya Dy Patil school of Engineering and Technology Pune, India

Prof. Nagesh Shelke

Department of civil engineering, Ajeenkya Dy Patil school of Engineering and Technology Pune, India

Abstract -The present research concentrates on finding the optimum outrigger location in a 60-storey non-orthogonal reinforced cement concrete (RCC) high-rise structure subjected to wind loads, considering variations in seismic zones and soil conditions. The building is modelled and analyzed using ETABS, with three different outrigger configurations located at 0.3H, 0.56H, and 0.75H. The structural behavior is examined under varying wind-speed conditions associated with the selected seismic zones and soil classifications. The analytical results indicates that changes in seismic zone and soil type do not influence the modal time period of the structure. Among the configurations considered, the outrigger system placed at 0.3H demonstrates better performance in controlling the building deflection. The findings emphasize that the strategic placement of outriggers plays a significant role in enhancing the lateral stability and overall wind- resistant performance of non-orthogonal high-rise RCC buildings.

Keywords -High-rise building, non-orthogonal RCC structure, outrigger system, wind loading, seismic zones, soil conditions, ETABS.

  1. INTRODUCTION

    The construction of high-rise buildings has become an integral part of contemporary urban development, driven by rapid population growth, increasing urbanization, and the growing demand for residential, commercial, and institutional spaces. Such buildings provide an efficient solution to land scarcity in densely populated metropolitan areas. Nevertheless, increasing building heights introduce greater challenges in structural engineering, particularly due to the influence of lateral loads induced by wind and earthquakes. Unlike low-rise structures, tall buildings are more susceptible to lateral deflections, overturning effects, and complex dynamic responses. Wind loading, in particular, can generate substantial lateral displacement and inter-storey drift, which may adversely affect structural integrity, cause damage to non- structural components, and reduce the comfort and safety of occupants. Consequently, the selection of an appropriate

    structural system is essential to achieve adequate strength, stiffness, stability, and satisfactory performance under extreme wind conditions.

    Reinforced cement concrete (RCC) is widely adopted in high-rise construction owing to its strength, durability, widespread availability, and versatility in architectural applications. However, conventional RCC moment-resisting frame systems, when used independently, may not provide adequate lateral stiffness for buildings of considerable height. To overcome this limitation and improve resistance against lateral forces, various structural systems are incorporated into high-rise buildings. These include shear wall systems, central core walls, braced frames, belt trusses, and outrigger systems, which enhance the overall stiffness, stability, and lateral load- resisting capacity of the structure.

  2. BUILDING CONFIGURATION AND ANALYTICAL MODEL

    1. Building configuration

      TABLE 1 BUILDING CONFIGURATION

      Total Number of Floors

      Ground +60 floors

      How many basements

      No Basements

      Number of Residential Floors

      35 Floors

      Number of Refuge Floors

      5 Floors (Partly)

      Total Height of the building above ground floor

      206 Meter (Above Ground Level)

    2. Sesimic and Wind Parameter

      TABLE 2 SEISMIC PARAMETERS

      Structural system

      Seismic Zone

      Zo ne fac tor (Z)

      Soil Type

      Impor tance Factor (I)

      Respo nse Redu ction factor

      (R)

      II

      0.1

      0

      Building

      III

      0.1

      with

      ductile RC

      6

      Hard/Medi

      um/Soft

      1.2

      4

      IV

      0.2

      shear walls

      4

      V

      0.3

      6

      TABLE 3 WIND PARAMETERS

      Zone II

      Zone III

      Zone IV

      Zone V

      Jaipur

      Pune

      Patna

      Guwah

      ati

      Vb (basic wind speed)

      47

      m/sec

      39

      m/sec

      47

      m/sec

      50

      m/sec

      K1 (Risk coefficient) (for 20 years mean probable design

      life)

      0.88

      0.9

      0.88

      0.874

      k2 (Terrain category 3)

      1.31

      1.31

      1.31

      1.31

      K3 (Topography

      factor)

      1

      1

      1

      1

      K4 (Importance factor)

      1

      1

      1

      1

    3. Analytical Modeling And Outrigger Locations

      Fig. 1 Non-Orthogonal Structural Framing Plan with outrigger locations

      Fig. 2 3-D View of outrigger locations

      Fig. 3 Deflection Profile of Building without outrigger

      Fig. 4 Deflection Profile of Building -Outrigger At 0.3H

      Fig. 5 Deflection Profile of Building -Outrigger At 0.56H

      Fig. 6 Deflection Profile of Building -Outrigger At 0.75H

  3. RESULTS AND DISCUSSION

      1. Modal Time Period Comparison at Different Outrigger Locations Across Zones and Soil Strata

        TABLE 4 TIME PERIOD ZONE 2 & HARD STRATA

        TABLE 5 TIME PERIOD ZONE 3 & HARD STRATA

        TABLE 6 TIME PERIOD ZONE 4 & HARD STRATA

        TABLE 7 TIME PERIOD ZONE 5 & HARD STRATA

        Observation & Discussion

        Time Period Comparison Across Zones-Hard Soil Strata

        Mode 1: The modal time period is nearly similar in Zones Z2, Z3, Z4, and Z5 for all four models. Model Z2/Z3/Z4/Z5_H shows the highest time period (approximately 10.30 sec), while OT1 shows the lowest (approximately 10.07 sec).

        Mode 2: The modal time period remains constant in all zones. Model Z2/Z3/Z4/Z5_H has the highest value of 8.74 sec, followed by OT3 (8.60 sec), OT2 (8.47 sec), and OT1 (8.40 sec).

        Mode 3: Model Z2/Z3/Z4/Z5_H shows the highest time period of 8.49 sec, followed by OT3 (8.25 sec), OT2 (8.08 sec), and OT1 (7.98 sec).

        TABLE 8 TIME PERIOD ZONE 2 & MEDIUM STRATA

        TABLE 9 TIME PERIOD ZONE 3 & MEDIUM STRATA

        TABLE 10 TIME PERIOD ZONE 4 & MEDIUM STRATA

        TABLE 11 TIME PERIOD ZONE 5 & MEDIUM STRATA

        Time Period Comparison Across Zones-Medium Soil Strata

        Mode 1: The modal time period remains same across Zones Z2, Z3, Z4, and Z5 for all four models. Model Z2/Z3/Z4/Z5_M indicates the highest time period of approximately 10.30 sec, while OT1 has the lowest value of approximately 10.07 sec.

        Mode 2: The modal time period is unchanged across all four seismic zones. Model Z2/Z3/Z4/Z5_M has the highest

        value of 8.74 sec, followed by OT3 at 8.60 sec, OT2 at approximately 8.47 sec, and OT1 at 8.40 sec.

        Mode 3: Model Z2/Z3/Z4/Z5_M shows the highest time period of 8.49 sec, followed by OT3 at 8.25 sec, OT2 at 8.08 sec, and OT1 at 7.98 sec. These values remain constant across all zones.

        TABLE 12 TIME PERIOD ZONE 2 & SOFT STRATA

        TABLE 13 TIME PERIOD ZONE 3 & SOFT STRATA

        TABLE 14 TIME PERIOD ZONE 4 & SOFT STRATA

        TABLE 15 TIME PERIOD ZONE 4 & SOFT STRATA

        Time Period Comparison Across Zones-Medium Soil Strata

        Mode 1: The time period remains unchanged across Zones Z2, Z3, Z4, and Z5 for all four structural models. Model Z2/Z3/Z4/Z5_S exhibits the highest time period of approximately 10.30 sec, while OT1 has the lowest value of approximately 10.07 sec.

        Mode 2: The time period remains similar across all four seismic zones. Model Z2/Z3/Z4/Z5_S has the highest value of

        8.74 sec, followed by OT3 at 8.60 sec, OT2 at approximately

        8.47 sec, and OT1 at 8.40 sec.

        Mode 3: The time period remains similar across all four seismic zones. Model Z2/Z3/Z4/Z5_S has the highest value of

        8.49 sec, followed by OT3 at 8.25 sec, OT2 at approximately

        8.08 sec, and OT1 at 7.98 sec

      2. Building Displacement at Different Outrigger Locations Due To Along Wind & Across Wind Forces

        TABLE 16 TIME Along wind (GWX, GWY) & Across wind (AWYX, AWXY) Displacement at outrigger locations in Zone 2 & 4 in Hard, Medium & Soft Soil Strata

        Observation

        The highest GWY value is 397.88 for the original configuration, while the highest AWYX value is 324.89 for the same configuration. Both values decrease with OT1 and increase slightly with OT2 and OT3

        GWX: The maximum value is 121.92 for the original configuration, and the minimum is 121.13 at OT1. AWXY: The maximum value is 193.14 for the original configuration, and the minimum is 186.75 at OT1

        TABLE 17 TIME Along wind (GWX, GWY) & Across wind (AWYX, AWXY) Displacement at outrigger locations in Zone 3 & 4 in Hard, Medium & Soft Soil Strata

        Z3_H/M/S

        Story

        Height

        GWX

        GWY

        AWYX

        AWXY

        TERRACE

        3.1

        83.35

        273.14

        200.62

        124.42

        Z3_H/M/S_OT1

        Story

        Height

        GWX

        GWY

        AWYX

        AWXY

        TERRACE

        3.1

        82.84

        270.49

        196.31

        122.20

        Z3_H/M/S_OT2

        Story

        Height

        GWX

        GWY

        AWYX

        AWXY

        TERRACE

        3.1

        83.04

        271.04

        197.98

        122.65

        Z3_H/M/S_OT3

        Story

        Height

        GWX

        GWY

        AWYX

        AWXY

        TERRACE

        3.1

        83.20

        272.05

        199.30

        123.50

        Observation

        The highest GWY value is 273.14 for the original configuration, while the highest AWYX value is 200.62 for the same configuration. Both values decrease with OT1 and increase slightly with OT2 and OT3

        GWX: The maximum value is 83.35 for the original configuration, and the minimum is 82.84 at OT1. AWXY: The maximum value is 124.42 for the original configuration, and the minimum is 122.20 at OT1

        TABLE 18 TIME Along wind (GWX, GWY) & Across wind (AWYX, AWXY) Displacement at outrigger locations in Zone 3 & 4 in Hard, Medium & Soft Soil Strata

        Z5_H/M/S

        Story

        Height

        GWX

        GWY

        AWYX

        AWXY

        TERRACE

        3.1

        138.58

        451.99

        382.32

        227.02

        Z5_H/M/S_OT1

        Story

        Height

        GWX

        GWY

        AWYX

        AWXY

        TERRACE

        3.1

        137.67

        446.82

        374.73

        219.39

        Z5_H/M/S_OT2

        Story

        Height

        GWX

        GWY

        AWYX

        AWXY

        TERRACE

        3.1

        138.03

        447.89

        377.68

        220.94

        Z5_H/M/S_OT3

        Story

        Height

        GWX

        GWY

        AWYX

        AWXY

        TERRACE

        3.1

        138.30

        449.87

        379.99

        223.84

        Observation

        Highest values: The original configuration has the highest GWY (451.99) and AWYX (382.32).

        Lowest values: Both GWY (446.82) and AWYX (374.73) reach their minimum at OT1

        GWX: Maximum = 138.58 for the original configuration; minimum = 137.67 at OT1.

        AWXY: Maximum = 227.02 for the original configuration; minimum = 219.39 at OT1

  4. VALIDATION AGAINST PUBLISHED BENCHMARK

    The model validation was carried out with reference to two previously published studies: Haghollahi et al. (2012), Optimization of Outrigger Locations in Steel Tall Buildings Subjected to Earthquake Loads, presented at the 15th World Conference on Earthquake Engineering (15WCEE), Lisbon, and Samat et al. (2008), The Optimum Location of Outrigger in Reducing the Along-Wind and Across-Wind Responses of Tall Buildings, published in the Malaysian Journal of Civil Engineering. These studies investigated the influence of outrigger positioning on the structural response of tall buildings under earthquake and wind loading, respectively. Their findings indicate that effective outrigger positioning generally lies within the middle-to-lower and middle portions of the building height, depending on the structural configuration and loading conditions. Based on the comparison with these studies, the present investigation considers outrigger locations of 0.3H, 0.56H and 0.75H measured from the building base. The results identify the 0.3H location as the most effective among the configurations investigated for the non-orthogonal RCC high-rise building.

  5. CONCLUSION

      1. The fundamental modal time period of the building remains unchanged with variations in seismic zone and soil strata. This indicates that, the modal time period is primarily governed by the structural mass and stiffness properties.

      2. The seismic zone influences the seismic demand on the structure; however, it does not alter the fundamental modal time period in the present study. This is because the seismic zone factor affects the magnitude of seismic forces rather than the inherent mass and stiffness characteristics of the structural system.

      3. Similarly, variations in soil strata do not produce a noticeable change in the fundamental modal time period of the building models considered. The soil classification influences the seismic design response and corresponding spectral acceleration, while the structural modal properties remain approximately constant.

      4. Among the three investigated configurations, the outrigger positioned at 0.3H where H is height of the building exhibited the most effective structural performance. This configuration provided better control of the overall building deflection compared with the other investigated outrigger locations.

      5. The effectiveness of the outrigger positioned at 0.3H was observed under different wind-speed conditions associated with the seismic zones considered in the study.

      6. The comparison of different outrigger configurations demonstrates that the vertical positioning of outriggers plays an important role in controlling the lateral response of high-rise buildings. Therefore, appropriate selection of outrigger location is essential for achieving improved structural performance.

REFERANCES

  1. Haghollahi et al. (2012), Optimization of Outrigger Locations in Steel Tall Buildings Subjected to Earthquake Loads, presented at the 15th World Conference on Earthquake Engineering (15WCEE)

  2. Smith, B. S., & Salim, I. (1981). Parameter study of outrigger-braced tall building structures. Journal of the Structural Division, 107(10), 2001 2014)

  3. Samat, R. A., Ali, N. M., & Marsono, A. K. (2008). The optimum location of outrigger in reducing the along-wind and across-wind responses of tall buildings. Malaysian Journal of Civil Engineering, 20(2).

  4. John, N. E., & Kamath, K. (2023). An investigation on optimal outrigger locations for hybrid outrigger system under wind and earthquake excitation. Asian Journal of Civil Engineering, 24, 759778

  5. Kim, H.-S., Lim, Y.-J., & Lee, H.-L. (2020). Optimum location of outrigger in tall buildings using finite element analysis and gradient- based optimization method. Journal of Building Engineering, 31, Article 101379.

  6. Kavyashree, B. G., Patil, S., & Rao, V. S. (2021). Evolution of outrigger structural system: A state-of-the-art review. Arabian Journal for Science and Engineering, 46, 1031310331R. Nicole, Title of paper with only first word capitalized, J. Name Stand. Abbrev., in press.

  7. Xing, L., Gardoni, P., Zhou, Y., & Zhang, P. (2024). Optimal models of outrigger locations and damping parameters for combined energy dissipation outrigger systems subject to seismic and wind loads. Journal of Building Engineering, 84, Article 107209M. Young, The Technical Writers Handbook. Mill Valley, CA: University Science, 1989.