Dynamic Behavior of High Rise RC Building with A Vertical Irregularities

DOI : 10.17577/IJERTCONV10IS10029

Download Full-Text PDF Cite this Publication

Text Only Version

Dynamic Behavior of High Rise RC Building with A Vertical Irregularities

1Deepika R, 2Raman Dip Mahato, 3Pankaj Yadav, 4Dhiraj Kumar Sah, 5Shaniahlang Lyngdoh 1Assistant Professor, Department of Civil Engineering, R R Institute of Technology, Bangalore, India. 2,3,4,5 Students, Department of Civil Engineering, R R Institute of Technology, Bangalore, Karnataka

Abstract Earthquake damages are caused due to deficiency in few aspects such as, the building with irregularities, soft storey, insufficient lateral strength, structural behavior between the building and the ground. In Modern Urban Infrastructure, irregular structure constitutes a larger portion. Also, it is the major characteristics which affect the structure during earthquake. Irregular Structures are those which have discontinuity in geometry, distribution of mass, stiffness. This project deals with an analytical study of a Stiffness irregularity i.e., soft storey behavior of a simple high-rise building under the dynamic loads. The analysis is carried out with response spectrum. Tall building is considered having stiffness irregularity, i.e., making different floors as a soft storey and masonry wall is used for stiffening the other floors. The main parameters are focused on time period, storey drifts, storey displacement, storey stiffness. The bare frame possesses high displacement and the risk of deflection during earthquake is high. Hence providing the lateral load resisting unit is important to minimize the risk of failure. Infill walls with openings have weak performance compared to the walls without openings. Anyhow, some portion of openings can be provided which will be less effective to earthquake forces. Since stiffness is directly proportional to the modulus of elasticity of the infill walls, material property and quality of this infill will vary the seismic responses of the structure. Displacement resistance and controlling the drift can be achieved by the addition of infill walls in turn, improves the stiffness of the structure.

KeywordsTall building, Soft Storey, Storey drift, Storey Displacement etc.

  1. INTRODUCTION

    Due An Earthquake is the most natural disaster in which shaking of the earth's surface takes place. Ground rupture and ground shaking are the most vulnerable effects creates by earthquakes, resulting in less or more severe destruction to building and other rigid infrastructure. Though many studies and experiments are done about earthquake, it is difficult to avoid the structure undergoing damage or failure during this distinctive shaking. Earthquake damages is caused due to deficiency in few aspects such as, the building with irregularities, soft storey, insufficient lateral strength, structural behavior between the building and the ground (type of foundation used).

    IRREGULAR STRUCTURES

    In Modern Urban Infrastructure, irregular structure constitutes a larger portion. Also, it is the major characteristics which affect the structure during earthquake. Irregular Structures are those which have discontinuity in geometry, distribution of mass, stiffness. As per IS Code 1893 (Part 1):2002,

    irregularities are classified as Plan Irregularities and Vertical Irregularities.

    Soft storey is one of the reasons for the failure of the structure during earth shaking. It is also the Stiffness defect which comes under vertical Irregularities. The recent trend is to construct the high rise building with an open ground floor which is used as a parking area or for any other utilities. These structures are usually designed as framed structure, having a masonry wall at the upper floors. This wall makes the upper floors to be stiffer against the lateral loads in compared to ground floor and the building is performed as a soft storey. According to IS 1893:2002 (part 1), Soft storey is in which the lateral stiffness will be less than 70% of the stiffness in the above storey or it will be less than 80% of the average lateral stiffness of other above 3 storys.

    The code suggests following considerations for a building with soft storey. (Page 27)

    • Special arrangements are done to make the lateral strength and stiffness of the soft storey more.

    • Members are designed according to the analysis carried out, i.e., dynamic analysis.

    • after the analysis is over, the beams and columns should be

      designed to satisfy more than 2.5 times of the obtained moments and shear.

    • Apart from the above column design, shear wall should be placed symmetrically on both sides of the building.

    • These walls to be designed for 1.5 times the lateral storey shear force.

  2. OBJECTIVES

    This paper deals with an analytical study of a Stiffness irregularity of the building structure i.e. soft storey behavior of a simple high-rise building under the dynamic loads. Tall building is considered having stiffness irregularity, i.e., making different floors as a soft storey and masonry wall is used for stiffening the other floors. The building will be modeled and designed using ETAB V18 software and dynamic analysis are carried out.

    The main parameters are focused on time period, storey drifts, storey displacement, and storey stiffness.

  3. ANALYSIS AND PROBLEM DESCRIPTION

    An RCC building of 50mX30m is considered having a special moment resisting frame of 35 storeys. ETABS V15.2 is the software used for analyzing the frame. Inputs are mentioned below.

    TABLE I. DETAILS OF THE MODEL

    Sl. No

    Description

    Details

    1

    Storey height

    Base- 4.5m

    Typical- 3m

    2

    Materials

    Steel, Concrete and masonry

    3

    Codes

    IS 456:2000.

    IS 875-1987 (Part II) – Live Loads/ Design Loads,

    IS 875 (Part III): 1987 – For Wind

    Loads

    IS 1893 (Part 1): 2002 For

    Earthquake Designing

    TABLE II. LIVE LOAD DETAILS

    SL. No.

    Type of Loads

    Floor

    Details

    1

    Live Load

    Typical floor Terrace Floor

    2kN/m² 1.5kN/m²

    2

    Super Dead Load (SDL)

    Typical floor Terrace Floor

    1kN/m²

    Case 1: Bare Frame Model (BFM)

    Case 2: Building with Infill walls and soft storey effect at different floors

    Model 1: Soft storey at 1st/ Ground Floor and other floors having infill walls. (M1)

    Model 2: 10th floor having soft storey effect with others as infill walls. (M2)

    Model 3: Building with soft storey effect at 20th floor and remaining floor are infill walls. (M3)

    Model 4: 30th storey is without infill walls and rest are having infill walls (M4)

    Model 5: 35th/Terrace floor are soft storey and all others with infill walls. (M5)

    Case 3: Buildings having infill walls with the openings for above all the 5models. (OM1, OM2,OM3, OM4, OM5)

    1. Bare frame Model

    2. Results

    • Infill walls with openings have weak performance compared to the walls without openings. Anyhow, some portion of openings can be provided which will be less effective to earthquake forces.

    • The approach of conventional design -in which assumption

      is made that loads ae carried by frame and infill walls act like divider, may not be suitable for structure present in the high seismic zone consisting of the open ground floor which possess soft storey effect.

    • Soft storey should be checked carefully and then the

      structure should comprises of sufficient stiff by means of shear wall or braces.

    • Lateral strength can be increased by two ways, by

      providing stiffer columns or by constructing infill walls at particular floor where there is a deficiency in stiffness.

    • Arrangement and placing of the infill walls are most important to minimize the soft storey effect.

    • Since, stiffness is directly proportional to the modulus of

      elasticity of the infill walls, material property and quality of these infill will vary the seismic responses of the structure.

    • Displacement resistance and controlling the drift can be

      achieved by the addition of infill walls in turn, improves the stiffness of the structure.

  4. CONCLUSION

The bare frame possesses high displacement and the risk of deflection during earthquake is high. Hence providing the lateral load resisting unit is important to minimize the risk of failure.

  • Open ground floor (M1) is having more displacement value

    compared to other models with different soft storey levels. The failure of the structure with open ground floor will be more during earth's shaking. Hence, soft storey effect at ground floor is not preferable.

  • Due to soft storey, sudden increase in the drift can be seen

in that floor. Stiffness will be more for the storey having infill walls and bare frame is weak in stiffness.

REFERENCES

[1] Seismic evaluation of high-rise building with vertical irregularities by pushover analysis mr. Syed shoaib syed mehboob dr.m. L. Waiker (vol- 06, issue no-02, 2021, nanded)

[2] analysis of effect of structural irregularity in multistorey building under seismic loading syeda sofiya rahman, p. M. Shimpale (vol- 06, issue no-02, 2021, maharashtra)

[3] dynamic analysis of rc building having vertical irregularity mohammadismail s memon dr. Abhijitsinh parmar (vol- 06, issue no-07, 2021, gujarat)

[4] behavior of vertical irregular building in different seismic zones asra fathima, shashi kumar n v (vol- 07, issue no-08, 2020, karnataka)

[5] response characteristics of structures having irregularity subjected to vertical excitations nishant laxmikant agrawal (vol- 07, issue no-07, 2020, maharashtra)

[6] dynamic behavior of multi-story concrete buildings based on non-linear pushover & time history analyses sherif gamal abd-elhamid1, reham mohamed galal ebrahim el-tahawy, mohamed nour el-din fayed (vol- 05, issue no- 02, 2020, egypt)

[7] study on dynamic behaviour of high riser dual system with in-plane discontinuity in vertical elements resisting lateral loads manasa b r, m r suresh (vol- 04, issue no- 10, 2017, karnataka)

[8] analysis of the effects of vertical irregularity on isolated structures anthony quansah, xiao zhirong (vol- 06, issue no- 06, 2017, china)

[9] seismic analysis of multi-storied building having vertical irregularities using pushover analysis t.m.prakash, b.g. naresh kumar, punith n, mallamma (vol-06, issue no- 05, 2017, karnataka)

[10] twin tower high rise building subjected to seismic loading surendra chaurasiya, sagar jamle (vol- 06, issue no-04, 2019, indore)

[11] effect of vertical irregularity in multi-storied building under seismic loading alaa h. Al-zuhairi1, ali hussein ali al-ahmed1, fahad m. Abdulkarimc, hasan hussein ali, mohammed h. Mohammed. (issue no- 03, iraq)

[12] performance evaluation of high-rise building with reinforced concrete flag walls under seismic load manoj pillai, roshni john (vol- 10, issue no- 05, 2019, kharghar)

[13] study of plan irregularity on high-rise structures prof. M.r. wakchaure anantwad shirish, rohit nikam. (vol-01, issue no- 08, 2012, maharastra)