🌏
Global Research Platform
Serving Researchers Since 2012

Corrosion Inhibition of Mild Steel by 1-Benzyl-3-Methylimidazolium Chloride in 2M H2SO4 and 3.5% Nacl Media

DOI : 10.17577/IJERTV3IS041832

Download Full-Text PDF Cite this Publication

Text Only Version

Corrosion Inhibition of Mild Steel by 1-Benzyl-3-Methylimidazolium Chloride in 2M H2SO4 and 3.5% Nacl Media

  1. S. Velrani1, P. Muthukrishnan2, B. Jeyaprabha3, * P. Prakash4

    1. Department of Chemistry, Karpagam University, Coimbatore-641021, Tamilnadu, India. 2 & 4*. Department of Chemistry, Thiagarajar College, Madurai-625009, Tamilnadu, India.

  1. Department of Civil Engineering, Fatima Michael College of Engg & Tech.,Madurai-625020, Tamilnadu, India.

    Abstract -The acid and chloride corrosion inhibition process of mild steel in 2M H2SO4 and 3.5% NaCl media by 1-benzyl-3- methylimidazolium chloride (BMIC) has been investigated using weight loss method, potentiodynamic polarization and electrochemical impedance spectroscopy. The inhibition efficiency increased with increase in the concentration of the inhibitor in both media. The effect of temperature on the corrosion behavior in the presence of inhibitor was studied in the temperature range of 308-328K. The adsorption of the studied inhibitor on the mild steel obeyed Langmuir adsorption isotherm. Protective film formation against acid and chloride attack was confirmed by Scanning electron microscopy (SEM) and Fourier transform infrared spectroscopy (FT-IR) techniques.

    Keywords – Imidazolium chloride, Inhibition, Corrosion, Steel, Acid, Chloride

    1. INTRODUCTION

Mild steel is widely used in many industrial applications. In most industrial processes, the acidic solutions are commonly used for the pickling, industrial acid cleaning, acid descaling oil well acidifying, etc.[1-4] and mild steel also comes in contact with chloride ions very frequently under numerous conditions and circumstances in industries. Chloride ions are known to be aggressive towards mild steel and cause severe corrosion problems. Many examples exist of their use in combination with other inhibitors to improve the protection of metals [5- 7]. Corrosion prevention systems favor the use of environmental chemicals with low or zero environmental impacts. The decreasing of corrosion rate of metals provides saving of resources and economical benefits

Organic compounds bearing heteroatoms with high electron density such as phosphor, sulphur, nitrogen, oxygen or those containing multiple bonds which are considered as adsorption centers, are effective as corrosion inhibitor [8,9]. Ionic liquids (Imidazolium chloride) are organic salts that melt below 100C. Unlike traditional solvents, ionic liquids are comprised entirely of ions. The interest in ionic liquids stems from their potential as green solvents because of chemical and thermal stability, nonflammability, very low or negligible vapour pressure, high ionic conductivity, and a wide electrochemical potential window, which makes them potentially attractive alternative for volatile organic solvents. Recently, a variety of applications [10-13] of ionic liquids have been widely investigated. In particular, the most extensively studied ionic liquids are based upon the imidazolium cation. Imidazolium compounds are reported to show corrosion resistant behavior on copper [14] mild steel and Aluminum. It was found that the action of such inhibitors depends on the specific interaction between functional groups and the metal surface, due to the presence of the CN group and electronegative nitrogen in the molecule.

B. About the study

2

The purpose of this paper is to evaluate 1-benzyl-3- methylimidazolium chloride (BMIC) as corrosion inhibitor for mild steel in different media. The adsorption and inhibition efficiency of this inhibitor was investigated and the thermodynamic adsorption parameter in absence and presence of inhibitor was calculated. The molecular formula of the BMIC is C11H13N + Cl- and its chemical

during the industrial applications as well as increasing the

lifetime of equipment and also decreasing the dissolution of toxic metals from the components into the environment. Therefore, the prevention of metals used in industrial applications from corrosion is vital that must be dealt with. The use of organic molecules as corrosion inhibitors is one of the most practical methods for protecting metals against the corrosion and it is becoming increasingly popular.

structure is shown in Fig.1.

  1. EXPERIMENTAL

    1. Preparation of Electrode

      Fig 1. Chemical structure of BMIC

      where Wb and Wa are the specimen weight before and after immersion in the test solution respectively, S is the surface

      area of the specimen and t is the end time of each

      The mild steel specimens were cut from a cylindrical rod to a length of 5cm and inserted to polyester resin leaving only 0.5 cm2 of the surface area exposed to electrolyte. The electrical conductivity was provided by a copper wire. The chemical composition of working electrode (wt) was C (0.13%), Mn (0.39%), Si (0.18%), S (04%), P (0.40%) and Fe (remainder).

    2. Test Solutions

      The corrosion tests were performed in 2M H2SO4 solution and 3.5% NaCl solution in the absence and presence of BMIC. The inhibitor (BMIC) was purchased from Sigma Aldrich Company. The corrosive solution of 2M H2SO4 (AR grade) and 3.5% NaCl (AR grade) were prepared in distilled water and used for all studies. The concentrations of the inhibitor employed were varied from 0.002M to 0.01M in acid medium and 0.0002M to 0.001M in chloride medium. For each experiment, a freshly prepared solution was used.

    3. Weight Loss Measurements

      The mild steel specimens of 3cmx3cmx0.6cm dimensions were abraded with different grades of emery papers, washed with distilled water, degreased with acetone, dried with air. After weighing accurately the specimens were immersed in solutions containing 2M H2SO4 solution in acid medium and 3.5% NaCl solution in chloride medium with and without various concentrations of BMIC. The experimental studies were performed at different temperature (from 308K to 328K) maintained in a thermostated water bath. The temperature maintenance in all immersion was around 24 hrs. The solution volume was

      100 ml. The coupons were withdrawn from the tested solution, washed thoroughly with distilled water followed by acetone and dried with air, then weighed again. Weight loss was used to calculate the corrosion rate () and inhibition efficiency (IE) as follows:

      Wb – Wa

      = ————– (1)

      st

      experiment. The IE (%) values were being calculated from WL data by using Eq. (2):

      IE WL (%) = (0- )/ 0 × 100 (2)

      where 0 is a corrosion rate without inhibitor and is a corrosion rate with inhibitor.

    4. Electrochemical Measurements

      Polarization study was carried out using H & CH electrochemical workstation impedance Analyzer Model CHI 604D provided with iR compensation facility, using three-electrode cell assembly. A double wall one- compartment cell with a three-electrode configuration was used. Mild steel was used as a working electrode and platinum electrode as counter electrode and calomel as reference electrodes. The corrosion parameters such as linear polarization (LPR), Corrosion potential (Ecorr), corrosion current (Icorr) and Tafel slopes (bc and ba) were measured. During the polarization study, the scan rate (v/s) was 0.001; Hold time at Ef (s) was zero and quiet time (s) was 2. AC impedance spectra were recorded in the same instrument using three-electrode cell assembly. The real part and imaginary part of the cell impedance were measured in ohms for various frequencies. The charge transfer resistance (Rct) and doule layer capacitance (Cdl) values were calculated using the relation:

      Rct = (Rs + Rct) Rs (3)

      Cdl = ½Rctfmax (4)

      Where fmax = maximum frequency and Rs = Solution resistance. AC impedance was recorded with initial E(v) = 0 High frequency (Hz) = 1×105, Low frequency (Hz) = 0.1, Amplitude (v) = 0.005 and Quiet time (s) = 2. The working surface area was 0.5cm2, abraded with emery paper (grade 600-1200) on test face, rinsed with distilled water, degreased with acetone, and dried with a cold air steam. Before measurement the electrode was immersed in test

      solution at open circuit potential (OCP) for 20 min to be sufficient to attain a stable state. All electrochemical measurements were carried out at 308K using 100ml of electrolyte (2M H2SO4 and 3.5% NaCl) in stationary condition. Each experiment was repeated at least three times to check the reproducibility.

    5. Scanning Electron Microscopy (SEM)

      The mild steel specimens were immersed in acid and chloride solutions in the presence and absence of inhibitor for a period of 24 h. After 24 h, the specimens were taken out and dried. The nature of the surface film formed on the surface of the mild steel specimen was analyzed by using JEOL (JSM 6390) Scanning electronic microscopy.

    6. Fourier Transform- Infrared spectroscopy (FT-IR)

    The BMIC (Coated on KBr disc) was characterized by FT-IR spectroscopy (8400S SHIMADZU spectrometer. After immersion in 2M H2SO4 and 3.5% NaCl with addition of BMIC for 24 h, the specimen was cleaned with distilled water, dried with a cold air. Then the thin adsorption layer formed on steel surface was rubbed and it was characterized by the same spectrophotometer.

  2. RESULT AND DISCUSSION

  1. Weight Loss Measurements

    The corrosion rate of mild steel specimens after exposure to 2M H2SO4 solution and 3.5% NaCl solution at different temperatures ranging from 308-328K with and without the addition of various concentrations of BMIC was calculated and the data obtained are given in Table 1. It can be seen that, the addition of inhibitor to the aggressive solution reduces the corrosion rate of mild steel. The maximum inhibition efficiency was found to be 83.38% in acid medium at 0.01M and 80.79% in chloride medium at 0.001M at 308K, which indicated that BMIC was a good inhibitor in both media. Table 1 shows that the corrosion rate decreased and inhibition efficiency increased with increasing inhibitor concentration in both media suggests that the inhibitor molecule act by adsorption on the metal surface and the decrease of inhibition efficiency with increase of temperature in acid and chloride media (Fig.2&3), which could be attributed to the shift of the adsorption-desorption equilibrium toward desorption .

    Fig 2. Dependence of mild steel corrosion rate on the concentration, Inhibition efficiency for different temperature and Inhibition efficiency for different concentrations of BMIC in acid medium at different temperatures.

    Table 1 Corrosion rate, Inhibition efficiency and Surface area data obtained from weight loss method for mild steel in acid medium of BMIC & chloride medium of BMIC.

    T (K)

    Acid medium of BMIC

    Chloride medium

    of BMIC

    Conc. (M)

    ×105 (gcm²min¹)

    IE (%)

    Conc. (M)

    ×106 (gcm²min¹)

    IE (%)

    308

    Blank

    9.819

    Blank

    5.243

    0.002

    7.079

    27.90

    0.2790

    0.0002

    2.031

    61.26

    0.6126

    0.004

    5.911

    39.80

    0.3980

    0.0004

    1.901

    63.74

    0.6374

    0.006

    4.512

    54.05

    0.5405

    0.0006

    1.649

    68.54

    0.6854

    0.008

    3.289

    66.50

    0.6650

    0.0008

    1.302

    75.17

    0.7517

    0.01

    1.631

    83.38

    0.8338

    0.001

    1.007

    80.79

    0.8079

    313

    Blank

    9.940

    Blank

    5.347

    0.002

    7.871

    20.81

    0.2081

    0.0002

    2.283

    57.31

    0.5731

    0.004

    6.259

    37.03

    0.3703

    0.0004

    2.109

    60.55

    0.6055

    0.006

    4.668

    53.05

    0.5305

    0.0006

    1.823

    65.91

    0.6591

    0.008

    3.955

    60.22

    0.6022

    0.0008

    1.563

    70.78

    0.7078

    0.01

    2.174

    78.13

    0.7813

    0.001

    1.128

    78.90

    0.7890

    318

    Blank

    9.957

    Blank

    5.451

    0.002

    8.056

    19.10

    0.1910

    0.0002

    2.465

    54.78

    0.5478

    0.004

    6.462

    35.10

    0.3510

    0.0004

    2.309

    57.64

    0.5764

    0.006

    4.744

    52.35

    0.5235

    0.0006

    2.023

    62.90

    0.6290

    0.008

    4.049

    59.34

    0.5934

    0.0008

    1.753

    67.83

    0.6783

    0.01

    2.372

    76.17

    0.7617

    0.001

    1.328

    75.64

    0.7564

    323

    Blank

    9.964

    Blank

    5.59

    0.002

    8.198

    17.72

    0.1772

    0.0002

    2.613

    53.26

    0.5326

    0.004

    6.687

    32.89

    0.3289

    0.0004

    2.561

    54.19

    0.5419

    0.006

    4.885

    50.98

    0.5098

    0.0006

    2.214

    60.40

    0.6040

    0.008

    4.272

    57.13

    0.5713

    0.0008

    1.953

    65.06

    0.6506

    0.01

    2.588

    74.03

    0.7403

    0.001

    1.58

    71.74

    0.7174

    328

    Blank

    9.972

    Blank

    5.686

    0.002

    8.398

    15.79

    0.1579

    0.0002

    2.821

    50.38

    0.5038

    0.004

    7.09

    28.90

    0.2890

    0.0004

    2.769

    51.30

    0.5130

    0.006

    5.045

    49.41

    0.4941

    0.0006

    2.413

    57.56

    0.5756

    0.008

    4.584

    54.03

    0.5403

    0.0008

    2.153

    62.14

    0.6214

    0.01

    2.793

    71.99

    0.7199

    0.001

    1.788

    68.55

    0.6855

    Fig.3.Dependence of mild steel corrosion rate on the concentration, Inhibition efficiency for different concentrations of BMIC in chloride medium at different temperatures.

  2. Potentiodynamic Polarization Measurements

    The representative potentiodynamic polarization curves of mild steel in 2M H2SO4 and 3.5% NaCl solution in the absence and presence of various concentrations of BMIC are shown in Fig 4(a&b). The values of related electrochemical parameters i.e. corrosion potential (Ecorr), corrosion current density (icorr), corrosion rate and inhibition efficiency were calculated from the related polarization curves and are given in Table 2. The inhibition efficiency was calculated from polarization measurements according to the relation given below;

    corr

    corr corr

    IE% = (i0corr – icorr / i0 ) ×100 (5) where i0 and i are the uninhibited and inhibited corrosion current densities, respectively.

    . .

    As it can be clearly seen from fig 4a, the presence of inhibitor causes a prominent decrease in the corrosion rate, i.e., shifts the anodic curves to more positive potentials and the cathodic curves to more negative potentials, and to lower values of current densities. Namely, both cathodic and anodic reactions of mild steel electrode corrosion are inhibited by BMIC in 2M H2SO4. This may be ascribed to adsorption of inhibitor over the corroded surface. This reveals that BMIC can be classified as mixed type inhibitor in 2M H2SO4 medium. It follows from fig 4b that the BMIC suppressed the cathodic reaction to great extent than anodic one. This behavior is typical of

    mixed type inhibitor w(i5th) cathodic predominance in 3.5%

    NaCl medium

    Fig 4a. Tafel plots for mild steel immersed in 2 M H2SO4 and 3.5%NaCl containing different concentration of BMIC at 308K.

    Fig.4b. Tafel plots for mild steel immersed in 2 M H2SO4 and 3.5%NaCl containing different concentration of BMIC at 308K

    Table 2 Potentiodynamic polarization parameters for the corrosion of mild steel in 2M H2SO4 and 3.5%NaCl in the absence and the presence of BMIC.

    Medium

    Cinh(M)

    Ecorr(mV)

    icorr(Acm-2)

    bc (V/decade)

    ba

    (V/ decade)

    Rp (/cm2)

    %IE

    2MH2SO4

    Blank

    -522

    8.766×10-3

    5.129

    6.860

    4.10

    0.002

    -516

    4.175×10-3

    5.383

    7.661

    8.00

    53.01

    0.004

    -521

    3.637×10-3

    5.353

    7.888

    9.00

    58.50

    0.006

    -521

    3.788×10-3

    5.125

    7.699

    9.00

    56.78

    0.008

    -523

    9.888×10-4

    5.286

    7.538

    27.8

    58.50

    0.01

    -528

    3.646×10-4

    4.917

    8.755

    87.2

    84.70

    3.5%NaCl

    Blank

    -672

    8.148×10-5

    4.266

    9.908

    412.10

    0.0002

    -673

    1.021×10-5

    5.022

    11.704

    2415.8

    87.46

    0.0004

    -681

    8.495×10-6

    5.120

    11.913

    2846.3

    89.57

    0.0006

    -722

    6.155×10-6

    5.352

    9.633

    3443.0

    92.40

    0.0008

    -683

    4.991×10-6

    5.310

    13.662

    4260.9

    93.87

    0.001

    -695

    3.419×10-6

    5.450

    13.397

    5880.6

    95.80

    Cathodic current potential curves give rise to parallel Tafel lines indicating that hydrogen evolution reaction by the BMIC investigated occur by simple adsorption mode and the mechanism is the same with and without inhibitor. In anodic domain, the addition of BMIC in both media leads to decrease in the current densities in large potential domain. In this case desorption rate of BMIC is raised more than its adsorption [15]. From Table

    2 reveals that the corrosion current (icorr) decreases and inhibition efficiency increases with the inhibitor concentration. No definite trend was observed in the shift of corrosion potential (Ecorr) values, in the presence of various concentrations of BMIC in both media. This result suggests that the addition of BMIC reduces anodic dissolution and also retards hydrogen evolution reactions as

    would be expected and therefore BMIC on mild steel is caused by geometric blocking effect [16].

  3. Electrochemical Impedance Spectroscopy Measurements

    The effect of inhibitor concentration on the impedance mild steel in 2M H2SO4 and 3.5% NaCl media at 308K is presented in Fig 5(a&b). The curves show a similar type of Nyquist plot for mild steel in the presence of various concentrations of BMIC in acid medium. As seen in Fig 5a, the Nyquist plot contains depressed semi- circles indicating a charge transfer process mainly controlling the corrosion of mild steel. Such behavior is

    characteristic for solid electrodes and often referred to frequency dispersion, has been attributed to roughness and other inhomogeneities of the solid surface [17]. From fig. 5b shows the Nyquist plots of mild steel in 3.5% NaCl without and with different concentrations of BMIC. From these plots, the impedance response of mild steel in uninhibited in acid and chloride solution has significantly changed after the addition of BMIC in the corrosive solutions. This indicated that the impedance of the inhibited substrate has increased with increasing concentration of inhibitor. The characteristic parameters associated to the impedance diagram (Rct, Cdl and IE) are given in Table 3. In the case of impedance studies, IE% was calculated as:

    ct ct ct

    IE% = (R1 – R /R1 ) ×100 (6)

    ct

    Where Rct and R1 are uninhibited and inhibited charge transfer resistance respectively. It is clear from Table 3 that

    charge transfer resistance increased after addition of inhibitor concentration. On the other hand, the values of Cdl decreased with increase in the inhibitor concentration. This situation was the result o an increase in the surface coverage by the inhibitor in both media, which led to an increase in the inhibition efficiency [18]. This decrease in Cdl, which can result from a decrease in local dielectric constant and/or an increase in the thickness of double layer, suggested that BMIC molecules function by adsorption at the metal/solution interface.[19].

    The results obtained from polarization show a similar trend for the tested compound as those obtained from impedance and weight loss measurements but yield different value of inhibition efficiency due to different experimental conditions.

    Fig 5a. Nyquist plots for mild steel immersed in 2 M H2SO4 and 3.5%NaCl containing different concentration of BMIC at 308K.

    Fig.5b. Nyquist plots for mild steel immersed in 2 M H2SO4 and 3.5%NaCl containing different concentration of BMIC at 308K.

    Table 3 Electrochemical impedance parameters for mild steel in 2M H2SO4 and 3.5%NaCl in the absence and the presence of BMIC.

    Medium

    Cinh(M)

    Rs(cm2)

    Rct(cm2)

    Cdl(F/cm2)

    %IE

    2MH2SO4

    Blank

    1.636

    2.080

    8.647×10-2

    0.002

    1.693

    4.137

    2.097×10-2

    49.72

    0.004

    1.502

    5.436

    1.232×10-2

    61.74

    0.006

    1.536

    6.206

    9.367×10-3

    66.48

    0.008

    1.837

    10.703

    3.372×10-3

    80.57

    0.01

    1.839

    11.671

    2.680×10-3

    82.18

    3.5%NaCl

    Blank

    11.81

    156.59

    1.790×10-5

    0.0002

    11.16

    159.84

    1.560 x10-5

    2.030

    0.0004

    10.99

    200.01

    1.225 x10-5

    21.73

    0.0006

    11.60

    433.30

    3.151 x10-5

    63.86

    0.0008

    11.52

    788.18

    7.089 x10-7

    80.13

    0.001

    9.070

    1424.93

    1.848 x10-7

    89.01

  4. Effect of Temperature

    Temperature is an important parameter in studies on metal dissolution studies. To assess the effect of temperature on corrosion and corrosion inhibitive process, mass loss experiments were performed at 5K intervals in the temperature range 308328K in uninhibited acid and inhibited solutions containing different concentrations of BMIC. The relationship between the corrosion rate () and temperature (T) are expressed by the Arrhenius equation.

    log = logA Ea / 2.303RT (7) Where A is the frequency factor, Ea is the activation energy, R is the gas constant (R=8.314 J mol-1K-1) and T is the absolute temperature. Linear plots were obtained by plotting log against 1/T for the corrosion of mild steel in the absence and presence of different concentrations of inhibitor in acid and chloride media (Fig.6 (a&b)). The slope of the line was (-Ea/2.303R) and the intercept of the line extrapolated to (1/T=0) gave log A. The values of Ea were calculated from the slope of the straight lines and are listed in Table 4.

    In general Ea values in the presence of inhibitor were greater than its absence clearly indicated that the corrosion reaction of mild steel was inhibited by BMIC. Ea values for the inhibited system increase with inhibitor concentration in both acid and chloride media. At concentration of 0.006M in acid medium for BMIC, there is slightly decrease in Ea value is observed (Fig.7) with further increase in inhibitor concentration. The decrease in the Ea value at a level of inhibitor efficiency was reported

    in the literature [20,21]. The values of Ea values in the presence of inhibitor were greater than its absence clearly indicated that the corrosion reaction of mild steel was inhibited by BMIC. The increase in the activation energy in the presence of inhibitor signified physical adsorption. This conclusion was confirmed by the decrease in inhibition efficiency with increasing temperature. The change in enthalpy (H*) and entropy (S*) for the formation of activated complex in the transition state could be obtained from the transition state equation:

    log /T = {(logR/ hN) + (S*/2.303R)} (H*/ 2.303RT) (8)

    Where h is the Plancks constant, N is the Avogadros number and R is the gas constant. A plot of log /T vs 1/T gave straight line (Fig.8 (a&b)). The slope was (- H*/2.303R) and the intercept was {(log R/hN + (S*/2.303R)}, from which the values of H* and S* were calculated and presented in Table 4. The positive values of enthalpies (H*), ranged from 80.3-158.9 kJ/mol in acid medium and 114.4-189kJ/mol in chloride medium, reflected the endothermic nature of the steel dissolution process. The negative values of entropies (S*) implied that the activated complex in the rate determining step represented an association rather than dissociation step meaning that a decrease in disorder took place on going from reactants to the activated complex [22]. Thus a greater degree of orderliness appeared during its transformation from reactant to activated complex. In addition, the negative values of S* in the presence of inhibitor than its

    absence implied that the presence of inhibitor created a near-equilibrium corrosion system state [23].

    Fig 6a. Arrhenius plots for mild steel in the absence and presence different concentrations of BMIC in acid and chloride media.

    Fig 6b. Arrhenius plots for mild steel in the absence and presence different concentration of BMIC in acid and chloride media.

    Fig 7. Dependence of apparent activation energy on the concentration of 1-BMIC

    Fig 8a. Transition state plots for mild steel in the absence and presence different concentrations of BMIC in acid and chloride media.

    Fig.8b. Transition state plots for mild steel in the absence and presence different concentrations of BMIC in acid and chloride media.

  5. Adsorption Isotherm and Thermodynamic Parameters

    The adsorption of surfactants at metal/solution interfaces can markedly change the corrosion resisting properties of metals. The efficiency of organic molecules as good corrosion inhibitors mainly depends on their adsorption ability on the metal surface. So, the investigation of the relation between corrosion inhibition and adsorption is of great importance. The adsorption of organic inhibitors at the metal/solution interface takes place through the replacement of water molecules by organic inhibitor molecules according to following process [24].

    Org (sol) + xH2O (ads) ———--> Org (abs) + xH2O (sol) (9)

    Where Org (sol) and Org (ads) are organic molecules in the solution and adsorbed on the metal surface, respectively. x is the number of water molecules replaced by the organic molecules.

    Table 4 Corrosion kinetic parameters for mild steel in 2M H2SO4 and 3.5%NaCl in absence and presence of different concentration of BMIC.

    Cinh(M)

    Ea (kJ/mol)

    H*(kJ/mol)

    S*(J/mol/K)

    Acid medium

    Blank

    0.56

    80.3

    -490.79

    0.002

    6.55

    101.2

    -490.74

    0.004

    7.39

    105.4

    <>-490.72

    0.006

    7.41

    99.2

    -490.76

    0.008

    12.71

    126.4

    -490.68

    0.01

    21.46

    158.9

    -490.59

    Chloride medium

    Blank

    3.56

    114.4

    -490.76

    0.0002

    13.62

    153.1

    -490.66

    0.0004

    16.29

    161.8

    -490.64

    0.0006

    16.44

    163.5

    -490.64

    0.0008

    21.12

    179.7

    -490.59

    0.001

    23.51

    189.0

    -490.56

    The adsorption on the corroding surfaces never reaches the real equilibrium and tends to reach an adsorption steady state. However, when the corrosion rate is sufficiently small, the adsorption steady state has a tendency to become a quasi-equilibrium state. In this case, it is reasonable to consider the quasi-equilibrium adsorption in thermodynamic way using the appropriate equilibrium isotherms. It is essential to know the mode of adsorption and the adsorption isotherm that can give valuable information on the interaction of inhibitor and metal surface. In order to clarify the nature and the strength of adsorption the experimental results have been fitted to a series of adsorption isotherms and the best fit was obtained with the use of Langmuir adsorption isotherm.

    Langmuir adsorption isotherm can be expressed by the following equation.

    Cinh/ = 1 / Kads +Cinh

    (10)

    Where Cinh is inhibitor concentration. is the degree of the coverage on the metal surface and Kads is the equilibrium constant for the adsorption-desorption process. A plot of log C/ vs log C gave straight line (Fig.9 (a&b)). From intercept of the straight lines, the values of Kads were calculated as given in Table 5. From the table the correlation coefficients are very good and Kads values decreases with increasing temperature shows that the

    BMIC was physically adsorbed on the mild steel surface. The equilibrium constant for the adsorption-desorption process is related to the standard free energy of adsorption (G ) according to relation:

    ads

    ads ads

    G = -RTln(55.5K ) (11)

    Where R is the gas constant, T is the temperature and 55.5 is the molar concentration of water in solution. Generally the standard free energy of adsorption values of -20kJmol-1 or less negative are associated with an electrostatic inter action between charged molecules and charged metal surface (physical adsorption): those of -40kJmol-1 or more negative involves charge sharing or transfer from the inhibitor molecules to the metal surface to form a co- ordinate covalent bond (chemical adsorption) [25,26]. The values of Gads were calculated from equation (11) and are recorded in Table 5. The negative values of Gads clearly indicated that spontaneous adsorption of BMIC on mild steel surface took place through physical adsorption mechanism in both media. Usually, values of Gads up to – 20 KJ/mol (as obtained in this study) signified physical adsorption, which was consistent with electrostatic interaction between charged molecules and a charged metal [23, 27]. Another form of Langmuirs adsorption isotherm was used to calculate the enthalpy of adsorption [60].

    ads

    logK = (-logCH2O+S /2.303R) –

    ads

    H /2.303RT (12)

    where CH2O is the molar concentration of water molecules, Hads is the standard heat of adsorption and Sads is the standard entropy of adsorption. The plots of log K versus 1/T are shown in Fig.10. The slope of the linear part of the curves is equal to -Hads/ 2.303R and the intercept is (-

    logCH2O + Sads./2.303R), from which the values of Hads and Sads were calculated and their values are given in Table 5. The negative values of Hads reflect the exothermic behavior of inhibitor on mild steel surface. Sads values were negative (decrease in entropy) because adsorption of these inhibitors was exothermic and Hads values were more negative than Gads values.

    Fig.9a: Plot of log C/ versus log C for mild steel in 2M H2SO4 and 3.5% NaCl containing different concentrations of inhibitor.

    Fig 9b: Plot of log C/ versus log C for mild steel in 2M H2SO4 and 3.5% NaCl containing different concentrations of inhibitor.

    Fig.10. Plot of log k versus 1/T for mild steel in 2M H2SO4 and 3.5% NaCl containing different concentrations of inhibitor.

    Table 5 Thermodynamic adsorption parameters for BMIC in mild steel of 2M H2SO4 and 3.5% NaCl media at different temperatures

    Temp(K)

    Kads (10-2M¹)

    G0

    ads

    (kJ/mol)

    H0ads

    (kJ/mol)

    S0ads(kJ/mol)

    Acid medium

    308

    5.297

    -10.60

    313

    3.594

    -10.67

    318

    3.206

    -10.82

    -28.59

    -84.7

    323

    2.922

    -10.97

    328

    2.518

    -10.95

    Chloride medium

    308

    16.69

    -10.29

    313

    13.84

    -10.49

    318

    13.08

    -10.62

    -11.58

    -19.54

    323

    13.25

    -10.79

    328

    12.11

    -10.95

  6. Scanning Electron Microscopy Studies

    The SEM images of mild steel in 2M H2SO4 and 3.5% NaCl solution in the absence and presence of BMIC after 24 h exposure are given in Fig .11(a&b) and 12(a&b). As it is shown in 11a and 12a, the mild steel surface was strongly damaged in the absence of inhibitors due to metal dissolution in corrosive solution. The surface was highly porous; the large and deep holes appeared. However, the appearances of mild steel surfaces were significantly different after the addition of inhibitors to the corrosive solution. It can be seen from Figs.11b and 12b that, the dissolution rate of mild steel reduced and the smooth surfaces appeared by formation of a protective film on the

    metal surface. Fig.11a. SEM images of mild steel in 2M H2SO4 a) without inhibitor.

    Fig.11b. SEM images of mild steel in 2M H2SO4 b) with inhibitor.

    Fig.12a. SEM images of mild steel in 3.5%NaCl a) without inhibitor.

    Fig.12b. SEM images of mild steel in 3.5%NaCl b) with inhibitor.

  7. FT-IR Studies

Several researchers [28] have confirmed that FTIR spectrometer is a powerful instrument that can used to determine the type of bonding for organic inhibitors absorbed on the metal surface. In this paper, FTIR spectrometer was used to identify whether there was adsorption and to provide new bonding information on the steel surface after immersion inhibited H2SO4 and NaCl solution.

The Fourier transform infrared spectroscopy of pure BMIC is shown in Fig. 13a and the FTIR spectrum of adsorbed protective layer formed on the surface after immersion in 2M H2SO4 and 3.5%NaCl contaning BMIC is shown in the Fig. 13(b&c). The frequencies and assignment of FTIR by BMIC, acid containing BMIC and chloride containing BMIC were shown in Table 6.

Table 6 Frequencies and assignment of adsorption of FTIR by BMIC, acid containing BMIC and chloride containing BMIC

BMIC

(frequency in cm-1)

H2SO4

containing BMIC (frequency in cm-1)

NaCl containing BMIC (frequency in cm-1)

Assignment

3390.86

3367.71

3367.71

N-H stretch

1633.71

1616.35

1616.35

C=N stretch

1444.68

1473.62

1471.69

C-H bend of CH2 group

1352.10

1384.89

1369.46

N-heteroaromatic imidazole ring

C-N stretch

1161.15,1097.50

1271.09

1257.59

&1022.27

C-H bend in benzene

840.96& 717.52

829.39

837.11&725.23

Fig. 13a.: FT-IR spectra of BMIC.

Fig.13b. FT-IR spectra of adsorbed layer formed on the mild steel after immersion in 2M H2SO4 containing inhibitor.

Fig.13c. FT-IR spectra of adsorbed layer formed on the mild steel after immersion in 3.5%NaCl containing inhibitor.

1V. CONCLUSION

Concluding the experimental part, it was clearly demonstrated that all the three techniques used, especially electrochemical techniques are able to characterize and to follow the inhibition of corrosion process promoted by 1- benzyl-3-methylimidazolium chloride (BMIC) and it was found to be a good inhibitor for the corrosion of mild steel in 2MH2SO4 and 3.5%NaCl media. The polarization curves indicated mixed type indicator of both anodic and cathodic processes in acid medium and typical of mixed type inhibitor with cathodic predominance in chloride medium. The electrochemical impedance diagrams showed mainly capacitive loop, which can be attributed to the formation of adsorbed layer on the steel surface. Inhibition efficiency increases with increase in BMIC concentration, but decrease with increase in temperature in both media. The adsorption BMIC on mild steel surface obeyed Langmuir adsorption isotherm. The thermodynamic parameters reveal that the inhibition of corrosion by BMIC is due to the formation of a physisorbed film on the metal surface.

REFERENCES

  1. Ahamad, M.A. Quraishi, Bis (benzimidazol-2-yl) disulphide: An efficient water soluble inhibitor for corrosion of mild steel in acid media, Corros. Sci.Vol.51, 2009, pp.2006-2013.

  2. Q.B. Zhang, Y.X. Hua, Corrosion inhibition of mild steel by alkylimidazolium ionic liquids in hydrochloric acid, Electrochem. Acta, Vol. 54, 2009, pp. 1881-1887.

  3. W. Li, q. He, C. Pei, B. Hou, Experimental and theoretical investigation of the adsorption behaviour of new triazole derivatives as inhibitors for mild steel corrosion in acid media, Electrochem. Acta Vol.52, 2007, pp. 6386-6394.

  4. G. Kardas, The Inhibition Effect of 2-Thiobarbituric Acid on the Corrosion Performance of Mild Steel in HCl Solutions , Mater. Sci. Vol.41, 2005, pp.337-343.

  5. D. Ferreday, P.J. Wilcox, B. Greaves, Method for measurement of corrosion rate at iron electrode in inhibited neutral water,.Brit Corros J, Vol.28, 1993,pp.185-190.

  6. J. Telegdi, E. Kalman, F.H. Karman, Corrosion and scale inhibitors with systematically changed structure, Corros Sci, Vol.33, 1992, pp 1099- 1102.

  7. A. Veres, G. Reinhard, E. Kalman, Synergistic inhibition in low chloride media,,Brit Corros J, Vol.27, 1992, pp 147-154.

  8. S.A. Abd El Maksoud, Studies on the effect of pyranocoumarin derivatives on the corrosion of iron in 0.5 M HCl, Corros. Sci. Vol.44, 2002, pp 803-808.

  9. M. Abdallah, Rhodanine azosulpha drugs as corrosion inhibitors for corrosion of 304 stainless steel in hydrochloric acid solution, Corros. Sci. Vol.44, 2002,pp 717-724.

  10. F. Endres, Ionic liquids: solvents for the electrodeposition of metals and semiconductors, Chem. Phys. Chem. Vol.3, 2002, pp 144-149.

  11. T. Sato, T. Maruo, S. Marukane, K. Takagi, Ionic liquids containing carbonate solvent as electrolytes for lithium ion cells, J. Power Sources Vol.138, 2004, pp 253-259.

  12. A. Balducci, U. Bardi, S. Caporali, M. Mastragostino, F. Soavi, Ionic liquids for hybrid supercapacitors, Eleatrochem.Commun. Vol.6, 2004, pp 566-572.

  13. L. Moens, D.M. Blake, D.L. Rudnicki, M.J. hale, Advanced Thermal Storage Fluids for Solar Parabolic Trough Systems, J. Solar Energy Eng. Vol.125, 2003,pp 112-118.

  14. R. Gasparac, C.R. Martin, E. Stupnisek- Lisac, In Situ and Ex Situ Studies of Imidazole and Its Derivatives as Copper Corrosion Inhibitors. II. AC Impedance, XPS, and SIMS Studies, J. Electrochem. Soc.Vol.147, 2000, pp548-554.

  15. F.Bentiss, F. Gassama, D.Barbry, L. Gengembre, H. Vezin, M. Lagrenee,

    M. Traisnel, Enhanced corrosion resistance of mild steel in molar hydrochloric acid solution by 1,4-bis(2-pyridyl)-5H-pyridazino[4,5- b]indole: Electrochemical, theoretical and XPS studies, Appl. Surf. Sci. Vol.252, 2006, pp 2684-2693.

  16. C.N. Cao, Corrosion Electrochemistry Mechanism, Chemical Industrial Engineering Press, Beijing, 2004, p. 235 (in Chinese)

  17. K. Juttner, Electrochemical impedance spectroscopy (EIS) of corrosion processes on inhomogeneous surfaces, Electrochem. Acta Vol.35, 1990, pp 1501-1509.

  18. M.Lebrini, F.Robert, P.A.Blandinieres, C.Roos, Anti-corrosive properties of S. tinctoria and G. ouregou alkaloid extracts on low carbon steel, Current applied physics, Vol.11, 2011, pp 714 724.

  19. B.Wang, M.Du, J.Zhang, C.J.Gao, The inhibition mechanism of imidazoline phosphate inhibitor for Q235 steel in hydrochloric acid medium, Corros. Sci.Vol.53, 2011, pp 353-361.

  20. L. Tang, G. Mu, G. Liu, The effect of neutral red on the corrosion inhibition of cold rolled steel in 1.0 M hydrochloric acid, Corros. Sci. Vol.45, 2003, pp 2251-2260.

  21. X. Li, G. Mu, Tween-40 as corrosion inhibitor for cold rolled steel in sulphuric acid: Weight loss study, electrochemical characterization, and AFM, Appl. Surf. Sci. Vol.252, 2005, p 1254-1259

  22. G.E.Badr, The role of some thiosemicarbazide derivatives as corrosion inhibitors for C-steel in acidic media, Corros. Sci. Vol.51(11), 2009, pp 2529-2536.

  23. Gulsen Avci, Corrosion inhibition of indole-3-acetic acid on mild steel in 0.5 M HCl, Physicochem.Eng.Aspects. Vol.317, 2008, pp 730-736.

  24. J.O.M. Bockris,A.K.N.Reddy, Modern Electrochemistry, Volume 2, Publised byPlenum Publishing Corporation, 227 West 17th,Street, New York,1976.

  25. E. Bayol, A. A. Gurten, M. Dursun, K. Kayakirilmaz, Adsorption Behavior and Inhibition Corrosion Effect of Sodium Carboxymethyl Cellulose on Mild Steel in Acidic Medium, Acta Phys. Chim. Sin. Vol.24 (12), 2008, 2236-2242.

  26. S.A. Umoren, I.B. Obot, E. E. Ebenso, N.O. Obi-Egbedi, The Inhibition of aluminium corrosion in hydrochloric acid solution by exudate gum from Raphia hooker, Desalination Vol.247, 2009, pp 561-572.

  27. N.Gunavathy, S.C,Murugavel, Corrosion Inhibition Studies of Mild Steel in Acid Medium Using Musa Acuminata Fruit Peel Extract, E- Journal of Chemistry Vol.9(1), 2012, pp 487-495.

  28. Q. Qu, S. A. Jiang, W. Bai, L. Li, Effect of ethylenediamine tetraacetic acid disodium on the corrosion of cold rolled steel in the presence of benzotriazole in hydrochloric acid, Electrochim.Acta Vol.52, 2007, pp 6811-116.

Leave a Reply