Seismic Analysis of Buildings Resting on Sloping Ground and Considering Bracing System

DOI : 10.17577/IJERTV3IS090871

Download Full-Text PDF Cite this Publication

Text Only Version

Seismic Analysis of Buildings Resting on Sloping Ground and Considering Bracing System

G Suresp

JNTUA College of Engineering, Ananthapuramu, Ananthapuramu, Andhra Pradesh

Dr. E Arunakanthi2 JNTUA College of Engineering, Ananthapuramu, Ananthapuramu,

Andhra Pradesh

Abstract:- Most of the constructions in hilly regions are constrained by local topography which results in the adoption of either a step back or step back &set back configuration. Due to this the structure is irregular by virtue of varying column heights leading to torsion and increased shear during seismic ground motion. The dynamic analysis is carried out using response spectrum method to the step back and step back & set back building frames. The dynamic response i.e. fundamental time period, storey displacement & drift, and base shear action induced in columns have been studied for buildings of different heights. These results show that the performance of step back & set back building frames are more suitable in comparison with step back building frames. But after considering bracings to the step back building frames, a better performance can be observed when compared with step back & set back building frames.

Keywords Hill slope angle, number of bays, Static analysis, response spectrum analysis, step back frames, step back & set back frames, step back with bracings.

  1. INTRODUCTION:

    The economic growth & rapid urbanization in hilly region has accelerated the real estate development. Due to this, population density in the hilly region has increased enormously. The adobe burnt brick, stone masonry & dressed stone masonry buildings are generally made over level ground in hilly regions. Since level land in hilly regions is very limited, there is a pressing demand to construct buildings on hill slope. Hence construction of multi-storey R.C .Frame buildings on hill slope is the only feasible choice to accommodate i n cr e as in g demand of residential & commercial activities.

  2. SIGNIFICANCE OF STUDY:

    It is observed from the past earthquakes, buildings in hilly regions have experienced high degree of demand leading to collapse though they have been designed for safety of the occupants against natural hazards. Hence, while adopting practice of multi -storey buildings in these hilly & seismically active areas, utmost care should be taken, making these buildings earthquake resistant. In these areas buildings with step back configuration frames may some times give worst results so bracing system is

    used for the these buildings and comparing the results with other configuration.

  3. SCOPE OF STUDY:

    Three dimensional space frame analysis is carried out for two different configurations of buildings ranging from 8 to 10 storeys resting on sloping and plain ground under the action of seismic load by using Etabs software. And also considering bracing system

    to step back building configuration. Dynamic response of these buildings, in terms of base shear, fundamental time period and displacement is presented, and compared within the considered configuration as well as with other configurations. At the end, a suitable configuration of building to be used in hilly area is suggested.

    The effects of the supporting foundation medium on the motion of structure gives soil structure interaction, but this may not be considered in the seismic analysis for structures supported on rock or rock like naterials.

  4. BUILDING CONFIGURATION:

    In the present study, two groups of building ( i.e. configurations) are considered, and these two are resting on sloping ground. The slope of ground is 27 degree with horizontal, which is neither too steep or nor too flat. The height and length of building in a particular pattern are in multiple of blocks (in vertical and horizontal direction), the size of block is being maintained at 7 m x 5 m x 3.5 m. The depth of footing below ground level is taken as 1.75 m where, the hard stratum is available. And two bays are considered.

    The buildings shown in figure 4.1, having step back configuration are labeled as STEP 8 to STEP 10 for 8 to 10 storey. Step back -Set back configuration of buildings is shown in figure 4.2, are designated as STEP 8 to STEP 10, according to height of building. .The building with equal number of storeys/bays have same floor area in two configurations.

    S

    r. N

    Types of

    Frame s

    No. of

    Store

    Colum n Size (mm)

    Bea m

    Size (m

    300

    STEP 8

    x

    1

    Step back fram es

    STEP 9

    400

    x

    230 x

    500

    STEP 10

    400

    x 8

    0

    STEP

    300

    SET

    x

    2

    Step back & set back frames

    8

    6

    0

    230 x

    500

    STEP SET 9

    400

    x 8

    0

    STEP

    400

    SET

    x

    1

    8

    0

    0

    3

    Bracings

    STEP 8,9,10

    230×300

    Fig: 1 Step back frames of 8 storey, 9 storey and 10 storey buildings

    In the present study, three groups of building ( i.e. configurations) are considered, out of which two are resting on sloping ground and third one is on plain ground. The first two are step back buildings and step back-setback buildings; and third is the set back building. The slope of ground is 27 degree with horizontal, which is neither too steep or nor too flat. The height and length of building in a particular pattern are in multiple of blocks ( in vertical and horizontal direction), the size of block is being maintained at 7 m x 5 m x 3.5 m. The depth of footing below ground level is taken as 1.75 m where, the hard stratum is available.

    Geometrical properties of members for different configurations of building:

    4.1 LOADINGS:

    Live load

    4 kN/m²

    Floor finish

    1.5 kN/m²

    Wall weight

    13.8 kN/m

    6.9 kN/m on roof

    Seismic loading:

    IS 1893

    Zone factor

    0.36 (zone V)

    Soil type

    I

    Importance factor

    1.5

    Response reduction, R

    5

    Ecc. Ratio

    0.05

    Seismic analysis of different configurations of buildings is carried out by Response S p e c t r u m as per IS 1893 (Part I): 2002. The buildings located in Z o n e V ( 0.36) with I m p o r t a n c e Factor as 1.5. Damping is 5% and Response Reduction Factor considered is 5.0 for special RC moment resisting frame.

    Fig: 2 Step back & set backframes of 8 storey, 9 storey and 10 storey buildings

    Fig: 3 Step back frames of 8 storey, 9 storey and 10 storey buildings with bracings:

    Fig: 4 Shows typical 3D view of Step back building frame.

    Fig: 5 Shows a typical 3 D view of Step back building frame with bracings.

    5.1.1 Displacement variation of step back and step back & set back frames :

    The variation of displacement for different number of storeys and configurations of building frames is shown below:

    0.003

    0.0025

    0.002

    0.0015

    0.001

    0.0005

    0

    5.1.1.1 Comparison of displacements between step back and step back & set back frames of 8 storey building:

    set n

    stepback

    stepback

    Fig:6 Shows a typical 3D view of Step &set back building frame.

    PARAMETRIC STUDY:

    A study of seismic behavior of a hill buildings resting on level ground and on sloping ground is done considering different configurations. These buildings are in the range of 8 to 10 storey with maximum height of buildings restricted to 35 m. The location of these building is in Seismic zone V. Bay width of frame is

    7.0 m x 5.0 m and in general story height considered as

    3.5 m. The depth of footing below ground level is considered about 1.75 m below ground surface.

    0 1 2 3 4 5 6 7 8

    0.003

    0.0025

    0.002

    0.0015

    0.001

    0.0005

    0

    1 2 3 4 5 6 7 8 9

    set n stepback

    stepback

  5. RESULTS AND DISCUSSION:

    Results are divided in to two parts, Both types of building frames such as step back and step back set back frames are compared and also step back with bracings and step back & set back frames are also compared under seismic loading using response spectrum method. The results obtained are e x p r e s s e d in t e r m s of b a s e shear, time period & top storey displacement.

    5.1 Comparison of Step back and Step back & Set back building frames:

    Analysis is carried out on these above mentioned configurations of building frames by considering different number of stories varying from 8 storeys to 10 storeys and results obtained are discussed in further sections.

          1. Comparison of displacements between step back and step back & set back frames of 9 storey building:

            0.003

            0.002

            0.001

            step & set

            back

            step back

            0

            0 1 2 3 4 5 6 7 8 9

            0.0035

            0.003

            0.0025

            0.002

            0.0015

            0.001

            0.0005

            0

            step & set

            back

            step back

            0.7

            0.6

            0.5

            0.4

            0.3

            0.2

            0.1

            0

            step & set

            back

            step back

            0 1 2 3 4 5 6 7 8 9

            0.7

            0.6

            0.5

            0.4

            0.3

            0.2

            0.1

            0

            1 3 5 7 9 11

          2. Comparison of displacements between step back and step back & set back frames of 10 storey building:

    0.004

    0.003

    0.002

    0.001

    step & set

    back

    step back

    1 2 3 4 5 6 7 8 9 10 11

    0

    step &

    set back

    step back

    0.0035

    0.003

    0.0025

    0.002

    0.0015

    0.001

    0.0005

    0

    1 2 3 4 5 6 7 8 9 10 11

    1 3 5 7 9 11

    step & set back

    step back

    5.1.2.2 Comparison of time period between step back and step back & set back frames of 9 storey building:

    step & set

    back

    step back

    1 3 5 7 9 11

    0.7

    0.6

    0.5

    0.4

    0.3

    0.2

    0.1

    0

    From the above graphs the displacement for top stories of step & set back and step back buildings shows that; the displacement in step back buildings are more compared to step & set back building frames. The nature of variation observed is non linear for all number of stories.

    5.1.2 Time period variation of step back and step back & set back frames:

    The t i m e p e r i o d variation f o r different number of storeys and configurations of building frames is shown below by considering 1 2 m o d e s .

    5.1.2.1 Comparison of time period between step back and step back & set back frames of 8 storey building:

    0.8

    0.7

    0.6

    0.5

    0.4

    0.3

    0.2

    0.1

    0

    1 3 5 7 9 11

    step & set back

    Storey

    step & set back(Vx)

    step back(Vx)

    Base

    38.83

    39.42

    1

    19.33

    16.09

    2

    125.7

    111.2

    3

    299.24

    266.87

    4

    362.86

    455.16

    5

    342.03

    610.87

    6

    260.69

    625.94

    7

    600.64

    1550.7

    8

    392.99

    1027.03

    step back

    5.1.2.3 Comparison of time period between step back and step back & set back frames of 10 storey building:

    0.8

    0.7

    0.6

    0.5

    2000

    1500

    1000

    step & set back

    0.4

    0.3

    0.2

    0.1

    0

    1 3 5 7 9 11

    step & set back step back

    500

    0

    1 2 3 4 5 6 7 8 9

    step back

    5.1.3.2 Comparison of storey shear between step back and step back & set back frames of 9 storey building:

    0.8

    0.6

    0.4

    0.2

    0

    1 3 5 7 9 11

    step & set back

    storey

    step & set

    back(Vx)

    step

    back(Vx)

    Base

    33.14

    40.8

    1

    10.09

    4.9

    2

    88.54

    77.56

    3

    228.61

    214.47

    4

    297.9

    403.99

    5

    305.95

    607.74

    6

    266.37

    746.49

    7

    196.97

    731.14

    8

    499.62

    1773.58

    9

    326.77

    1164.93

    step back

    From the above graphs time period for Step back frames are more when compared with Step & Set back frames. However time period for 9 and 10 storey building frames are nearly similar.

    5.1.3 Comparison of Storey Shear for different configurations:

    The storey shear for different storeys of different configurations is compared.

    5.1.3.1 Comparison of storey shear between step back and step back & set back frames of 8 storey building:

    2000

    1500

    1000

    step & set

    back

    step back

    500

    0

    1 2 3 4 5 6 7 8 9 10

    5.1.3.3 Comparison of storey shear between step back and step back & set back frames of 10 storey building:

      1. Comparison of Step back with bracings and Step & Set back Frames:

        1. Comparison of displacement between step back with bracings and step back & set back frames of 8 storey building:

          0.0025

          0.002

          0.0015

          step n set back

          0.001

          0.0005

          step back

          (bracings)

          0

          1 2 3 4 5 6 7 8 9

          0.0025

          storey

          step & set

          back(Vx)

          step

          back(Vx)

          0

          41.31

          41.09

          1

          11.46

          0.74

          2

          p>19.21

          53.07

          3

          110.07

          163.81

          4

          184.08

          341.54

          5

          246.73

          557.59

          6

          304.42

          769.4

          7

          359.53

          881.08

          8

          417.23

          838.94

          9

          612.9

          2002.22

          10

          438.41

          1304.62

          0.002

          0.0015

          0.001

          0.0005

          0

          1 2 3 4 5 6 7 8 9

          step n set back

          step back wih bracings

          2500

          2000

          1500

          1000

        2. Comparison of displacement between step back with bracings and step back & set back frames of 9 storey building:

          step & set

          back(Vx)

          step back(Vx)

          500

          0

          1 3 5 7 9 11

          From above graphs storey shear at base is more for Step back building frames when compared with Step & Set back frames. But for 10 storey building frame the storey shear at base is approximately similar but shear for other storeys are differ.

          0.0012

          0.001

          0.0008

          0.0006

          0.0004

          0.0002

          0

          1 3 5 7 9

          step & set back

          step back with bracings

          0.0012

          0.001

          0.0008

          0.0006

          0.0004

          0.0002

          0

          1 3 5 7 9

          step & set back

          step back with bracings

  6. CONCLUSION:

From the above data due to the seismic analysis for the structures with different loading combinations the following conclusions are drawn:

  1. As per IS 1893-2002 buildings with dual system consist of shear walls or bracing frames so that these are designed to resist the total design lateral force in proportion to their lateral stiffness. So Step back frames without bracings produce higher base shear as compared with step back & set back frames.

  2. The step back building frames without bracings give higher values of time period as compared with step back & set back frames.

  3. The step back building frames without bracings give higher values of top storey displacement as compared with step back & set back frames.

  4. The performance of step back frames without

        1. Comparison of displacement between step back with bracings and step back & set back frames of 10 storey building:

    0.0008

    0.0007

    0.0006

    bracings during seismic excitation can be effected more than other configurations of building frames. Hence, step back building frames without bracings on sloping ground are not desirable. However, it may be adopted by providing bracing system to control displacements.

  5. Step b a c k & set b a c k f r a m e s produces less torsion effects as compared to step back frames. In case step back building f rames are proposed, then step back frame shall be designed for higher moments

    0.0005

    0.0004

    0.0003

    0.0002

    0.0001

    0

    0.0008

    0.0006

    0.0004

    0.0002

    0

    1 3 5 7 9 11

    1 3 5 7 9 11

    step & set back

    step back with bracings

    step & set back

    step back with bracings

    induced in columns due to earthquake.

  6. As number of storeys increases time period & top storey displacement also increases.

  7. Step back frames with bracings gives less displacements compared with Step back frames with out bracings and also Step & Set back frames.

    7. REFERENCES:

    1. Satish Kumar and D.K. Paul., Hill buildings configuration from seismic consideration, Journal of structural Engg., vol. 26, No.3, October 1999, pp. 179-185.

    2. IS:1893 (I)-2002., Criteria for Earthquake Resistant Design of Structures BIS, New Delhi.

    3. S.S. Nalawade., Seismic Analysis of Buildings on Sloping Ground,

      M.E. Dissertation, University of Pune, Pune Dec-2003

    4. I.S. 1893(Part 1)-2002, Criteria for earthquake resistant design of structure, general provision and building, Bureau of Indian standards, New Delhi.

By comparing the Displacements between Step & Set back frames and Step back frames with bracings, can say that the displacements are much decreased for Step back frames as bracings are considered.

Leave a Reply