Rotor Side Converter Control of DFIG based Wind Energy Conversion System

DOI : 10.17577/IJERTV4IS080557

Download Full-Text PDF Cite this Publication

Text Only Version

Rotor Side Converter Control of DFIG based Wind Energy Conversion System

Meera G. S N. A Divya

PG Scholar, Dept of EEE Assistant Professor, Dept of EEE

Mar Baselios College of Engineering & Technology Mar Baselios College of Engineering & Technology Kerala University Kerala University

Palayam, Thiruvananthapuram, Kerala Palayam, Thiruvananthapuram, Kerala

Abstract Over the last ten years, the global wind energy capacity has increased rapidly and became the fastest developing renewable energy technology. But unbalances in wind energy are highly impacting the energy conversion and this problem can be overcome by using variable speed wind turbines. Doubly Fed Induction Generator (DFIG) based Wind Energy Conversion Systems (WECS) are gaining tremendous attention nowadays. In this paper the dynamic modeling of wind turbine driven DFIG is simulated using Matlab/Simulink and the results are analyzed for various wind velocities. A stator flux oriented vector control scheme is applied to the rotor side converter in order to control the stator active and reactive power produced by the DFIG. Also an Optimal Torque Control (OTC) MPPT technique is applied in order to track optimum power from the wind turbine. Also a comparison of the stator active power with and without MPPT has been analyzed in Matlab/Simulink.

KeywordsWindTurbine,Doubly-fed induction generator, Rotor-side Converter control, MPPT,OTC

  1. INTRODUCTION

    In the recent years, renewable energy systems have attracted the great interest because conventional sources of energy are limited and a number of problems associated with their use, like environment pollution, large grid requirements etc. Government of the whole world is forced for the alternative energy sources such as wind power, solar energy and small hydro-electric power [1]. Among the above given choices, wind energy is a realistic way of harnessing the natural energy. Wind energy has been intensively investigated in recent years in many different countries, which resulted in several different configurations like fixed speed system with a SCIG, the variable speed system with permanent magnet synchronous generator (PMSG) and the variable speed system with a DFIG to improve the efficiency, power rating, cost benefit effectiveness etc [2].

    Wind is highly variable in nature, so variable speed Doubly Fed Induction Generator based WECS offers many advantages compared to the fixed speed squirrel cage induction generators, such as reduced converter rating, cost, losses in result of that an improved efficiency, easy implementation of power factor correction, variable speed operation and four quadrants active and reactive power control capabilities . Due to variable speed operation, total energy output is much more in case of DFIG-based WECS, so capacity utilization factor is improved and cost of per unit energy is reduced [3].

    Fig.1 DFIG based WECS

    A DFIG based wind energy conversion system is shown in Fig.1. Here stator of the DFIG is directly connected to the grid and the rotor is connected to the grid via a back to back PWM Voltage Source Converter (VSC). There are a lot of advantages of using DFIG in wind energy conversion system. The main advantage is the ability of generator to supply power both at lagging and leading power factors. The other advantage is the control of the rotor voltages and currents enables the induction machine to remain synchronized with the grid while the wind turbine speed varies. The main reason for the popularity of the doubly fed wind induction generators is their ability to supply power at constant voltage and frequency while the rotor speed varies. Hence DFIG became more popular in wind power applications. Again controlling the DFIG from the rotor side makes the control process more cost effective as the rotor converters have to deal with comparatively less power when connected at the rotor side than when connected at the stator side.

    In this paper, a control strategy is presented for DFIG. The sub synchronous generating mode of DFIG is analyzed and a vector control is given to Rotor Side Converter (RSC), inorder to control the stator active and reactive power. A dynamic model of wind turbine driven DFIG is simulated using Matlab/Simulink. An MPPT technique is applied to the wind turbine inorder to track optimum power during subsynchronous mode . Also a comparison is made with and without MPPT and analysed the effect of stator active power.

  2. WIND TURBINE MODELING

    The possible amount of wind power, which can be harvested by a wind turbine, is limited theoretically to 58% of total power content of the wind, considering Betz limit [4-5]. The wind turbine power coefficient is typically lower than 0.45.The generalized mechanical equation of the wind turbine is given as

  3. MODELING AND ANALYSIS OF THE DOUBLY-FED INDUCTION GENERATOR

    A doubly-fed induction generator is as a standard wound rotor induction generator with its stator windings directly connected to the power grid and rotor connected to the power grid through a frequency converter [6-7]. The operation of DFIG can be analyzed using the classic theory of

    J dwr

    • B wr T T

      (1)

      rotating fields and well known d-q model, as well as both

      S dt s m e

      In which, J S is total inertia of the shaft, Bs is

      three-to-two and two-to-three axes transformations.

      The dynamic modeling of doubly-fed induction generator in synchronously rotating reference frame deqe

      friction coefficient, Tm

      is the torque with wind origin and Te

      involves the following equations.

      is the electromagnetic torque produced by the generator. The generated torque is given by

      Vsd

      Rs Isd

    • dsd

      dt s

      (6)

      Pm

      Tm

      r

      (2)

      Vsq Rs Isq

      dsq

      dt

      sdq

      (7)

      p

      Pm is the amount of mechanical power generated from the wind turbine.

      V R I

      drd

      (8)

      Pm 0.5AC

      , V 3

      (3)

      rd r rd dt

      r rq

      is the air density, A is the swept area, Cp is the coefficient

      V R I drd

      (9)

      of performance, is the Tip speed ratio.

      rq r rd dt r rq

      m R

      (4)

      The stator and rotor fluxes can be expressed as

      V 3

      There are a number of approximations available for

      sd

      Ls I sd

    • MIrd

      (10)

      Coefficient of Performance (Cp).

      sq Ls Isq MIrq

      (11)

      116

      21

      rd Lr Ird MIsd

      (12)

      p

      C 0.5176

      i

      0.4 5e t 0.006795

      (5)

      rd

      Lr Irq

    • MIsd

      (13)

      rd

      The electromagnetic torque is expressed as

      The Cp for constant wind is 0.48. Fig.2 shows the operating characteristics of wind turbine. From cut in speed

      Tem

      pM I

      Isq

      • Irq Isd

      (14)

      to rated speed, the machine runs below synchronous speed. During this period in order track optimum power several MPPT techniques are applied.

      The active and reactive power taken by the machine can be

      represented by the following equations.

      P 3 V I

      V I

      (15)

      s 2 ds ds

      qs qs

      Q 3 V I

      V I

      (16)

      s 2 ds ds

      qs qs

      Where d and q subscripts stand for the d-axis and q-axis components, r and s subscripts stand for rotor and stator, V stands for the constant grid voltage stands for flux, R stands for resistance, I stands for currnt, stands for the utility frequency, p stands for the number of pole pairs, r stands for the rotational speed of the generator rotor,

  4. BACK TO BACK CONVERTER

    Fig. 2. Operating characteristics of Wind Turbine

    A DFIG consists of a wound rotor induction generator (WRIG) with the stator windings directly connected to the three-phase grid/load and the rotor windings connected to a back-to-back partially rated (2030% rating)power converter. This allows DIFG to operate at a variety of speeds in response to changing wind speed. The

    back-to-back converter is a bi-directional power converter The equations related to this scheme is

    consisting of two conventional pulse width modulation

    V R i

    L

    didr

    L i

    (17)

    (PWM) voltage source converters and a common DC bus employing a DC link capacitor. Both stator and rotor are able

    dr r dr

    r dt

    sl r qr

    to supply the power, but the direction of active power flow through the rotor circuit is dependent on the wind speed and accordingly the generator speed. Below the synchronous

    Vqr

    Rr iqr

    Lr

    diqr

    dt sl

    Lr idr

    • Loims

    (18)

    speed, the active power flows from the grid to the rotor side and the rotor side converter (RSC) acts as voltage source inverter while grid side converter (GSC) acts as a rectifier. Due to the bi-directional power flow ability of the converter, the DFIG may operate as a generator or motor in both sub synchronously (0<slip<1) and super synchronously (slip<0).The higher the slip, the larger the electrical power, which is either absorbed or delivered through the rotor.

  5. CONTROL SCHEME

    A lot of research has been undergone in order to decouple the active and reactive power. Vector control scheme [8] is one of the most effective scheme for decoupled control of active and reactive power, which was first proposed by F. Blaschke.Various type of controllers are used like P-I controller, fuzzy logic controllers, sliding mode controller etc in the vector control scheme for the control of active and reactive power. P-I controller is the most primitive and highly used controller in power applications for its simplicity and easy applicability As the stator winding of DFIG is connected directly to the infinite grid, the magnitude and frequency of stator voltage can be approximately considered to be constant[9]. So DFIG usually adopts stator flux linkage oriented control strategy. DFIG based WECS needs control of Voltage source converter to achieve variable speed operation.

    A. Rotor Side Converter Control

    A vector control is applied to rotor side converter in order to control the stator active and reactive power. The direct axis loop is used to control reactive power where as the quadrature axis is for active power control [10]. A stator flux oriented vector control is applied to the rotor side converter [11]. The block diagram of the RSC controller is shown in Fig.3. The direct axis loop is used to control reactive power where as the quadrature axis is for active power control.

    Fig.3 Rotor side converter control

  6. MAXIMUM POWER POINT TRACKING TECHNIQUES

    Maximum Power variation with rotation speed of DFIG is predefined for each wind turbine. So for MPPT the control system should follow the tracking characteristic curve (TCC) of the wind turbine. Each wind turbine has TCC similar to the one shown in the figure. Due to the nature of the wind that is instantaneously changing, it is essential to include a controller that is able to track maximum peak regardless of any wind speed [12].

    Fig. 4. Tracking Characteristic Curve

    Several MPPT algorithms have been proposed [13] among this two methods in descried in [14] and [15] are best solution due to their adaptive tracking and self tuning capability. In [16] have compared some of the available MPPT algorithms for wind energy system. In [17] reviews the fundamentals of the available MPPT algorithms for wind energy system and compared three selected MPPT techniques and concluded that Optimal Torque Control method is simple, fast and more efficient.

    A. Optimal Torque Control Method

    Maintaining the operation of wind turbine at the opt ensures that the maximum exploitation of the available wind energy to be converted into mechanical energy [18].

    Fig. 5 Optimal Torque Controller

    The principle of this method is to adjust the DFIG torque according to a maximum power reference torque of the wind turbine at a given wind speed.

    T 1 R5 C p max 2

    (19)

    mopt 2

    3 m

    opt

    It is a torque control based method the optimum torque is given as the reference torque for the controller connected to the wind turbine.

  7. SIMULATION RESULTS AND DISCUSSION The response of the DFIG system is simulated for

    the case of step changes in the wind speed as shown in Fig.6.

    Fig.6.Variable wind speed

    Fig.7.Generator speed

    The variation of wind speed at 0, 0.5 and 1 sec is shown in fig.6. From 0 to 0.5 wind speed is 4m/s, from 0.5 to 1 it is 8m/s and beyond 1 it is 10m/s.

    Fig.8 Electromagnetic Torque

    Fig.9 Stator current

    Fig.10 Rotor current

    After the cut in speed the turbine starts generating power. When the wind speed increases the generator speed also increases[19-20]. When the wind speed is less than the rated speed rotor rotates at a speed less than the synchronous speed i.e. sub synchronous generating mode. Fig.7 shows the sub synchronous generating mode of DFIG for variable wind speed. Fig.8 shows that when wind speed increases the torque increases and as it is a generator the torque is negative.

    As the wind speed increases stator current and rotor current increases. The simulation results are shown in Fig.9 and Fig.10. Also when the speed of the generator rotor is less than the synchronous speed, the corresponding slip will be positive as shown in Fig.11.

    Fig.11. Slip

    Fig.12 shows the stator active power. A vector control is given to the rotor side converter. The stator active and reactive power is controlled by controlling the rotor side converter. By controlling the RSC using vector control the active power increases with increase in wind speed and the reactive power is controlled in order to improve the power factor at the stator. Below the synchronous speed, power is

    generated by the stator only. The reactive power required by the machine is generated by the rotor converter.

    The simulation results of controlled active and reactive power is shown in the Fig. 12 and 13. Here when wind speed increases the active power increases and the reactive power remains almost zero.

    Fig.12 Ps without MPPT

    Fig.13 Reactive power

    Fig.14 Optimum mechanical torque from wind turbine

    When a maximum power point tracking technique is applied to the wind turbine. Therefore optimum power will flow from stator to grid during sub synchronous speed. Fig.14 shows the optimum mechanical torque from wind turbine.

    The stator active power with MPPT is shown in the Fig.15. Also the rotor active power in Fig.16 shows that active power flows to the rotor from grid.

    Fig.15.Ps with MPPT

    Fig.16 Rotor active power

    A comparison of stator active power is made with and without MPPT controller. Using OTC the active power flow from stator to grid has been improved. Table.1 shows the comparison of active power with and without MPPT. The table shows that when the wind speed is 4, 6 and 8m/s the active power Ps without MPPT is 0.8, 7.25 and 15kW. When an Optimal Torque Control MPPT technique is enabled the active power flow from stator to grid is improved.

    Table 1: Comparison of stator active power

    Time(s)

    Wind speed(m/s)

    Ps without MPPT

    Ps with MPPT

    0

    4

    0.8kW

    1kW

    0.5

    8

    7.25kW

    10kW

    1

    10

    15kW

    18kW

  8. CONCLUSION

In this paper dynamic model of wind turbine driven DFIG is simulated using Matlab/Simulink and the simulation results for various wind velocities are analyzed. A vector control is applied to rotor side converter in order to control the stator active and reactive power. Also Optimal Torque Control MPPT technique is applied to the wind turbine in order to transfer optimum power from stator to grid during sub synchronous mode. A comparison is made and concluded that using OTC the active power flow from stator to grid has been improved.

REFERENCES

  1. Niassati, N., et al. "A new maximum power point tracking technique for wind power conversion systems." Power Electronics and Motion Control Conference (EPE/PEMC), 2012 15th International. IEEE, 2012.

  2. M. Liserre, R. Cardenas, M. Molinas, and J. Rodriguez, Overview of multi-MW wind turbines and wind parks, IEEE Trans. Ind. Electron., vol. 58, no. 4, pp. 10811095, Apr. 2011.

  3. S. Muller, M. Deicke, and R. W. De Doncker, Doubly fed induction generator systems for wind turbines, IEEE Ind. Appl. Mag., vol. 17, no. 1, pp. 2633, MayJun. 2002.

  4. Verdornschot M. Modeling and control of wind turbines using a continuously variable transmission [Masters thesis]. Eindhoven: Eindhoven University of Technology, Department of Mechanical Engineering; 2009.

  5. A.Tapia, G.Tapia, J.Ostolaza, Modeling and Control of a Wind Turbine Driven Doubly Fed Induction Generator, IEEE Trans on Energy Conv.Vol-18,No-2,June-2003.

  6. Ozpineci, Bhurak, and Leon M. Tolbert. "Simulink implementation of induction machine model-a modular approach." Electric Machines and Drives Conference, 2003. IEMDC'03. IEEE International. Vol. 2. Ieee, 2003.

  7. G. Abad, G. Iwanski, J. López, L. Marroyo, and M. A. Rodríguez, Doubly Fed Induction Machine: Modeling and Control for Wind Energy Generation Applications. Hoboken, NJ: Wiley, 2011.

  8. Pati, Swagat, and Swati Samantray. "Decoupled control of active and reactive power in a DFIG based wind energy conversion system with conventional PI controllers." Circuit, Power and Computing Technologies (ICCPCT), 2014 International Conference on. IEEE, 2014.

  9. M.Aktarujjaman, M.E.Haque, K.M.Muttaqi, M.Negnevitsky, and G.Ledwich, sch.of.Eng., Univ.of Tasmania, Hobart, TAS, Control Dynamics of a Doubly Fed Induction Generator Under Sub and Super- Synchronous Modes of Operation IEEE Conference Proceedings, 20- 24 July 2008, pages 1-9.

  10. C. Yik Tang, Y. Guo, and J. N. Jiang, Nonlinear dual mode control of variablespeed wind turbines with doubly fed induction generators,IEEE Trans on Control Systems Technology, in press.

  11. D.Chwa , Kyo-Beum Variable Structure Control of the Active and Reactive Powers for a DFIG in Wind Turbines , IEEE Trans on IndustrialApplications.Vol-46,No-6,Nov-Dec-2010.

  12. An Improved Control Strategy of Limiting the DC-Link Voltage Fluctuation for a Doubly Fed Induction Wind Generator by Jun Yao, Hui Li, Yong Liao, and Zhe Chen, Chongqing University, Chongqing, China. IEEE transactions on power electronics, vol. 23, no. 3, may 2008.

  13. W. Qiao, W. Zhou, and R. G. Harley Wind speed estimation based sensorless output maximization control for a wind turbine driving a DFIG IEEE Trans on Power Electronics, vol. 23, no. 3, pp May 2008.

  14. Raza Kazmi SM, Goto H, Hai-Jiao G, Ichinokura O. Review and critical analysis of the research papers published till date on maximum power point tracking in wind energy conversion system. In: 2010 IEEE Energy Conversion Congress and Exposition (ECCE). 2010. p. 4075 82.

  15. Hui J, Bakhshai A. A new adaptive control algorithm for maximum power point tracking for wind energy conversion systems. In: IEEE Power Electronics Spe-cialists Conference PESC. 2008. p. 40037.

  16. W. Qiao, W. Zhou, J. M. Aller, and R. G. Harley, Wind Speed Estimation Based Sensorless Output Maximization Control for a Wind Turbine Driving a DFIG, IEEE Trans. Power Electron., vol. 23, no. 3, pp. 11561169, May 2008.

  17. Abdullah, M. A., et al. "A review of maximum power point tracking algorithms for wind energy systems." Renewable and Sustainable Energy Reviews 16.5 (2012): 3220-3227.

  18. Kazmi SMR, Goto H, Hai-Jiao G, Ichinokura O. A novel algorithm for fast and efficient speed-sensorless maximum power point tracking in wind energy con-version systems. IEEE Transactions on Industrial Electronics 2011;58:2936

  19. Hansen, Anca D., et al. "Overall control strategy of variable speed doubly-fed induction generator wind turbine." Wind Power Nordic Conference. 2004.

  20. Hansen, Anca D., P. Sørensen, Florin Iov, and Frede Blaabjerg. "Overall control strategy of variable speed doubly-fed induction generator wind turbine." In Wind Power Nordic Conference. 2004.

Leave a Reply