Performance of Sifcon with Mineral Admixture

DOI : 10.17577/IJERTCONV5IS13100

Download Full-Text PDF Cite this Publication

Text Only Version

Performance of Sifcon with Mineral Admixture

M. Gowri1

1PG Student, Department Of Civil Engineering,

M.A.M College Of Engineering and Technology, Trichy, India.

Dr. G.Vani2

2Assistant professor, Department of Civil Engineering,

      1. College of Engineering and Technology trichy, India

        Abstract There are various types of concrete has been emerged to increase the strength. Among the various types SIFCON concrete plays a vital role. SIFCON is a ductile layer of high performance fibre concrete with significantly large amount of fibres, hence it can also be used to reduce the wear and tear. Silica fume under elevated temperatures. In this research SIFCON specimens are subjected to temperature range of 200oC,400oC and 600oC. The fibre volume fraction adopted is to be 10% in volume of SIFCON. The alignment of fibre is to be random along one direction and the type of fibre used is Hooked end steel fibre. Slurry Infiltrated Fibrous Concrete (SIFCON) is a high-strength, high performance material containing a relatively high volume percentage of steel fiber as compared to SFRC. It is also sometimes termed as high-volume fibrous concreteSIFCON composites has high strength when compared to the conventional concrete and fibre reinforced concrete. Developments during the last two decades have shown a marked increase in the number of structures involving the long time heating of concrete. High temperature resistance is one of the most important parameters which affects the durability and service life of materials.

        1. INTRODUCTION

          Slurry Infiltrated Fibrous Concrete (SIFCON) is a high- strength, high performance material containing a relatively high volume percentage of steel fiber as compared to SFRC. It is also sometimes termed as high-volume fibrous concrete. The concept of Slurry Infiltrated Fibre Concrete (SIFCON) was introduced by Lankard from the New Mexico Engineering Research Institute (NMERI) in 1983.The percentage of steel fibres in a cement matrix could be increased substantially. While comparing with Fibres Reinforced Concrete the SIFCON has relatively high percentage of fibre. In Fibre Reinforced Concrete there is 1% to 3% of fibre adopted in its volume, whereas in SIFCON there should be 5% to 20% of fibre adopted in its volume. The process of making SIFCON is also different, because of its high steel fibre content. While in SFRC, the steel fibres are mixed intimately with the wet or dry mix of concrete, prior to the mix being poured into the forms, SIFCON is made by infiltrating a low-viscosity cement slurry into a bed of steel fibres pre-packed in forms/moulds.

          The matrix in SIFCON has no coarse aggregates, but a high cementitious content. A cement-rich flowable mortar is the binder in SIFCON production. The usage of very high amounts of cement not only affects the production costs, but also has negative effects on the heat of hydration and may cause shrinkage problems. Replacing cement with mineral admixtures seems to be a feasible solution to these problems. Furthermore, incorporation of mineral admixtures may

          positively affect the durability of SIFCON products. However, it may contain fine or coarse sand and additives such as fly ash, micro silica. The matrix fineness must be designed so as to properly penetrate (infiltrate) the fibre network placed in the moulds, since otherwise, large pores may form leading to a substantial reduction in properties.

          There are three important aspects considered in the preparation of SIFCON. They are as follows:

          1. Fibre orientation.

          2. Fibre geometry.

          3. Matrix composition.

          Fibre orientation describes the alignment of fibres in the Prepacked moulds in the manner of parallel or perpendicular depends upon the loading axis. In order to attain the highest strength the fibre alignment is the important factor. The maximal fibre volume depends on the fibre geometry and the vibration, effort needed for proper compaction. The shorter fibres may pack denser than the longer ones and the higher fibre volumes can merely be achieved with careful and sufficient vibration. Fibre alignment affects the behaviour of a SIFCON product greatly. Fibres can be aligned parallel to the stress direction which will be taken place within the composite or can be placed randomly. The ultimate strength, residual strength, ductility, and energy absorption properties are all can be affected by the fibre alignment fibre geometry includes the type of fibre used in preparation of SIFCON. Generally Hooked end steel fibres, crimped fibres and straight fibres are used. Among these Hooked end steel fibres are widely used. The fibre lengths vary from 30mm to 60mm (1.2 to 2.4 in.). The aspect ratios range from 60 to100. Crimped and straight fibres have also been used for some applications. Matrix composition determines the use of plain mortar or along with the replacement of cement with the mineral admixture to improve its performance and workability.

          SIMCON is made using a non-woven steel fiber mats that is infiltrated with concrete slurry. Steel fibers produced directly from molten metal using a chilled wheel concept are interwoven into a 0.5 to 2 inches thick mat. This mat is then rolled and coiled into weights and sizes convenient to a customers application (normally up to 120 cm wide and weighing around 200 kg).As in conventional SFRC, factors such as aspect ratio and fiber volume have a direct influence on the performance of SIMCON. Higher aspect ratios are desirable to obtain increased flexural strength. Generally, because of the use of mats, SIMCON the aspect ratios of fibers contained in it could well exceed 500. Since the mat is already in a preformed shape, handling problems are

          significantly minimized resulting in savings in labor cost. Besides this, balling of fibers does not become a factor at all in the production of SIMCON.

        2. METHODOLOGY

Adjustment in mixing water = (V-35)* 4.55 = (37.4% 35)*4.55 = 2.40 ml Total water required = 160 + (2.40)

= 162.40 ml

Step-3 Calculation for weight of cement From ACI 211.4R Table 4.3.5(b) Take W / C ratio = 0.29 Weight of cement = 162.40 / 0.29

MIX DESIGN

5.1 DESIGN MIX FOR M60 GRADE OF CONCRETE AS PER IS 10262 2009

DESIGN STIPULATION:-

Target strength = 60Mpa

Max size of aggregate used = 20 mm Specific gravity of cement = 3.12

Specific gravity of fine aggregate (F.A) = 2.66 Specific gravity of Coarse aggregate (C.A) = 2.73

Dry Rodded Bulk Density of fine aggregate = 1665 Kg/m3 Dry Rodded Bulk Density of coarse aggregate = 1800Kg/m3

Step-1 Calculation for weight of Coarse Aggregate: From ACI 211.4R Table 4.3.3

Fractional volume of oven dry Rodded C.A for 20mm size aggregate is 0.64m3

Weight of C.A = 0.64*1800

= 1152 Kg/m3

= 560.02 kg/m3

Step-4 Calculation for weight of Fine Aggregate: Cement = 560.02 / 3.12*1000

= 0.1794 Water

= 162.40/ 1*1000

= 0.1624 CA

= 1152 / 2.73*1000

= 0.4219 Entrapped Air

= 2 / 100

= 0.020

Total = 0.7837m3

Volume of Fine Aggregate = 1-0.7837

Weight of Fine Aggregate = 0.2163*2.66*1000

= 575.358 kg/m3 25

Step-5 Super plasticizer: For 0.8% = (0.8 / 100)*583.53

= 4.668 ml

Step-6 Correction for water: Weight of water (For 0.8%)

=162.40 4.668

=157.73kg/m3

Requirement of materials per Cubic meter Cement = 560 Kg/m3 Fine Aggregate = 575.358 Kg/m3 Coarse Aggregate = 1152 Kg/m3 Water = 157.73 Kg/ m3 Super plasticizers = 4.6681 / m3

p>So the final ratio becomes Cement: Fine agg (kg/m3): Coarse agg (kg/m3): Water (l/m3): Super plasticizer (l/m3)

Step-2

Calculation for Quantity of Water: From ACI 211.4R Table

4.3.4 Assuming Slump as 50 to 75mm and for C.A size 20 mm the Mixing water = 160 ml

Void content of FA for this mixing water = 35%

Void content of FA (V) V = {1-(Dry Rodded unit wt / specific gravity of FA*1000)}*100

= [1-(1665/2.6*1000)]*100

= 37.4% 24

It has been identified from the reviews high volume Class C fly ash mixtures are suitable for autoclave production of high strength SIFCON. Fibre volume is the most important parameter that affects the behaviour of the SIFCON. Furthermore, the mechanical performance can be improved remarkably by autoclave curing compared to normal curing. The mechanical properties achieved in this research indicate that SIFCON compositions incorporating high volumes of FA and steel fibres may be an ideal material for the construction of seismic resistant structures and under the impact and explosion effects. It's been observed that the use of Polypropylene fibre may reduce the explosive spalling of concretes at elevated temperatures. It is recommended that SIFCON composites may be produced with a concrete cover against high temperature oxidation of steel fibres, especially for military structures. Hence SIFCON with its improved properties than the conventional concrete can be used as an effective alternative in special concreting purposes or where the conventional concrete does not meet the requirement.

In phase II have collected literature reviews and studied methodology.

REFERENCES

  1. Ben Young and EhabEllobody (2007) Design of cold-formed steel unequal angle compression members.Thin-Walled Structures 45 (2007) 330338

  2. Ben Young and EhabEllobody (2005) Buckling Analysis of Cold- Formed Steel Lipped Angle Columns.

  3. Ben Young (2004) Tests and Design of Fixed-Ended Cold- Formed Steel Plain Angle Columns.

  4. Borges Dinis. P and Dinar Camotim (2007) FEM-based analysis of the local-plate/distortional mode interaction in cold-formed steel lipped channel columns

  5. EhabEllobody and Ben Young (2005) Behavior of Cold-Formed Steel Plain Angle Columns

  6. Hancock (2003) Cold Formed steel structure

  7. Meiyalagan.M and Dr.S.Sukumar (2010) Investigation on Cold formed C section Long Column with Intermediate Stiffener & Corner Lips Under Axial Compression.

  8. Schafer (2008) The Direct Strength Method of cold-formed steel member design

  9. Schafer (2002) Local, Distortional, and Euler Buckling of Thin-

    Walled Columns

  10. Vijayasimhan M Marimuthu V. PalaniG.S.and Rama Mohan Rao P.(2013) Comparative Study on Distortional Buckling Strength of Cold-Formed Steel Lipped Channel Sections. Vol 2(4)

  11. Wang and Zhang (2009) Geometrically nonlinear Finite Element Model Of Spatial Thin-Walled Beams With General Open Cross Section vol 22 No.1.

  12. IS 801-1975- CODE OF Practice for use of Cold- Formed light gauge steel structural members in general building construction.

ACKNOWLEDGMENT

I sincerely express my deepest sense of thanks to project supervisor and coordinator Dr.G. Vani M.Tech., Ph.D., Associate professor for her valuable guidance and encouragement for completing my project work a great success.

Leave a Reply