Implementation of Closed Loop Control of Ac-Ac Converter for Power Factor Improvement

DOI : 10.17577/IJERTV1IS6193

Download Full-Text PDF Cite this Publication

Text Only Version

Implementation of Closed Loop Control of Ac-Ac Converter for Power Factor Improvement

Neeraj Priyadarshi Sr Asst.Professor

Geetanjali institute of technical studies Udaipur(Rajasthan)

Abstract This paper presented a control strategy for AC-AC Converter for Power factor improvement. A Single-switch parallel resonant converter for Induction heating is simulated and implemented. The circuit consists of input LC- Filter, bridge rectifier and one controlled power switch. The switch operates in soft commutation mode and serves as a high frequency generator. Output power is controlled via switching frequency. Steady state analysis of the converter operation is presented.. A closed loop circuit model for AC to AC converted induction heating system is also proposed. Experimental results are compared with simulation results. The converter input current is practically sinusoidal and its power factor is close to unity. The circuit topology is very simple since includes only one power switch. This switch operates in a soft commutation mode. The converter provides a wide-range power control. This converter has advantages like reduced hardware, reduced stresses and high power density. Closed loop circuit model is developed and it is successfully used for simulation studies. Simulations were obtained using MATLAB/SIMULINK. The simulation and

hardware results proved that the control scheme have the advantages of better static and dynamic characteristics, small overshoot of the system response, rapid dynamic response and good robustness.

Keywords: Induction heating, soft commutation mode, AC-AC Converter etc.

  1. INTRODUCTION

    As power electronic systems are extensively used not only in industrial field but also in consumer products. Static frequency converters have been extensively applied in industry as a medium frequency power supply for induction heating and melting installations. They are applied in all branches of the military, machine- building industries, jewellery, smithy heating, domestic heating cooking devices and other purposes. The ordinary circuit of an AC-AC converter for induction heating typically includes a controlled rectifier and a frequency controlled current source or a voltage source inverter. It is a well known fact that the input rectifier does not ensure a sine wave input current, and is characterized by a low power. Recently many studies of high power factor

    rectifiers with a single switch have been made. These schemes are also characterized by a close to sine wave input current. In addition, in the scheme of the AC-AC converter for induction heating is described. The input circuit of the converter is constructed similarly to the input circuit in which also ensures a high power factor. However the inverting circuit is constructed by traditional mode with four controlled switches. From the simulation results, the proposed control scheme and controller have the advantages of better static and dynamic characteristics, small overshoot of the system response, rapid dynamic response and good robustness.

  2. CIRCUIT DIAGRAM AND PRINCIPLE OF OPERATION

    In the scheme (Fig.1) of the AC-AC converter there are two main advantages: It is characterized by a high power factor and a sine wave input current. On the other hand the inverter circuit is constructed with a single controlled switch, which serves as a high- frequency generator for induction heating. In the scheme (Fig.1) of the AC-AC converter there are two main advantages: It is characterized by a high power factor and a sine wave input current. On the other hand the inverter circuit is constructed with a single controlled switch,

    which serves as a high-frequency generator for induction heating.

    Fig1.circuit diagram

    We suppose the switching frequency is much higher than the input line frequency and in the analysis we arbitrarily chose the time interval where vin>0

  3. MODE OF OPERATION

    The operating principles of the circuit are illustrated by Fig.2 and the theoretical waveforms

    Fig2(a).Mode I

    Interval 1: t0<t<t1

    The equivalent circuit is shown in Fig.2a. Four diodes D1-D4 and the switch S are off. In this interval the capacitor C charges up practically linearly at a rate and a polarity corresponding to the instantaneous input voltage vin.

    Fig2(b).Mode II

    Interval 2: t1<t<t2

    The equivalent circuit is shown in Fig.2b. Two diodes D1, D3 and the switch S are on. In this interval the capacitor C is discharging via the circuit C-D1-S-Lr-load-D3. This interval ends when the capacitor voltage reduces to zero.

    Fig2(c).mode III

    Interval 3: t2<t<t3

    The equivalent circuit is shown in Fig.2c. All the diodes and the switch S are on. In this interval the current through switch S flows via two parallel bridge branches. This interval ends when this switch current decreases to zero. At this moment the switch turns off and the process starts from the beginning.

    Fig3.Switching Waveforms

  4. INDUCTION HEATING

    Induction heating is the process of heating an electrically conducting object (usually a metal) by electromagnetic induction where eddy currents (also called Foucault currents) are generated within the metal and resistance leads to Joule heating of the metal. An induction heater (for any process) consists of an electromagnet, through which a high-frequency alternating current (AC) is passed. Heat may also be generated by magnetic hysteresis losses in materials that have significant relative permeability. The frequency of AC used depends on the object size, material type coupling (between the work coil and the object to be heated) and the penetration depth.

  5. PI CONTROLLER

    PI Controller (proportional-integral controller) is a feedback controller which drives the plant to be controlled with a weighted sum of the error (difference between the output and desired set- point) and the integral of that value. It is a special case of the common PID controller in which the derivative (D) of the error is not used.

  6. SIMULATION RESULTS

    Simulations have been obtained using MATLAB/SIMULINK. Experimental results have been obtained with a low power laboratory prototype of a single phase PWM converter. The main parameters are as followings: The circuit parameters are R0=60; L0=150H; C0=2.35F; Lr=22H; Li=8.0mH; Cin=0.94F and the switching frequency S= (62-113) x103 s-1

    Fig4:Open loop circuit

    Fig:5 Driving pulses

    Fig:6 AC output voltage

    Fig:7 Closed loop controlled AC-AC converter

    Fig:8 output voltage of open loop system

    Fig:9 Output voltage of closed loop system

  7. CONCLUSION:

    An AC-AC converter circuit for induction heating has been simulated and tested. The converter input current is practically sinusoidal and its power factor is close to unity. The circuit topology is very simple since includes only one power switch. This switch operates in a soft commutation mode. The converter provides a wide-range power control. This converter has advantages like reduced hardware, reduced stresses and high power density. Closed loop circuit model is developed and it is successfully used for simulation studies. The limitation of this converter is presence of DC component in the output current and operating frequency is limited to 11MHz. Simulation and experimental results demonstrate the actual converter capability to control the heat.

  8. REFERENCES:

    1. Bayindir, N.S.; Kukrer, O.; Yakup, M (May 2003).: DSP-based PLL controlled 50100 kHz 20 kW high-frequncy induction heating system for surface hardening and welding applications. IEE Proc.-Electr. Power Appl., Vol. 150, No.3, pp. 365-371.

    2. Okuno, A.; Kawano, H.; Sun, J.; Kuroka- wa, M.; Kojina,A.; Nakaoka, M. (July/August 1998) Feasible development of soft-switched SIT inverter with load-adaptive frequency-

      tracking control scheme for induction heating. IEEE Trans. Ind. Applicat., Vol. 34, No. 4, , pp. 713-718.

    3. Kifune, H.; Hatanaka, Y.; Nakaoka, M. (January 2004 ) Cost effective phase shifted pulse modulation soft switching high frequency inverter for induction heating applications. IEE Proc.-Electr. Power Appl., Vol. 151, No. 1, , pp. 19-25.

    4. Ogiwara, H.; Nakaoka, M. ( March 2003) ZCS high frequency inverter using SIT for induction heating applications. IEE Proc.- Electr. Power Appl., Vol. 150, No. 2, pp. 185-192.

    5. Mollov, S.V.; Theodoridis, M.; Forsyth,

      A.J. (January 2004): High frequency voltage- fed inverter with phase-shift control for induction heating, IEE Proc.-Electr. Power Appl., Vol. 151, No. 1, pp. 12-18.

    6. Ogiwara, H.; Gamage, L.; Nakaoka, M.( September 2001) Quasiresonant soft switching PWM voltage-fed high frequency inverter using SIT for induction heating applications. IEE Proc.- Electr. Power Appl., Vol. 148, No. 5, pp. 385-392.

    7. Singh, B.; Singh, B.N.; Chandra, A.; Al- Haddad, K.; Pandey, A.; Kothari, D.P (October 2003) A review of single-phase improved power quality AC-DC converters. IEEE Trans. Ind. Electron., Vol. 50, No. 5, pp. 962-981.

8..Singh, B.; Singh, B.N.; handra, A.; Al- Haddad, K.; Pandey, A.; Kothari, D.P. (June 2004) A review of three-phase improved power quality AC-DC converters. IEEE Trans. Ind. Electron., Vol. 51, No. 3, pp. 641-

660.

9..B.Saha, K.Y. Suh, S.K. Kwon, and M.Nakaoka, (Apr. 2007) Selective dual duty cycle controlled high frequency inverter using resonant capacitor in parallel with an auxiliary reverse blocking switch, J.Power Elecctron., vol.7, no.2, pp118-123.

Leave a Reply