DOI : 10.5281/zenodo.24466120
- Open Access
- Authors : Ruturaj Guru, Meghansh Somani, Apurva Shingane, Govardhan Sale, Dr. Shreenivas Londhe
- Paper ID : IJERTV15IS110957
- Volume & Issue : Volume 15, Issue 11 , November – 2026
- Published (First Online): 23-11-2026
- ISSN (Online) : 2278-0181
- Publisher Name : IJERT
- License:
This work is licensed under a Creative Commons Attribution 4.0 International License
Flow over a Hump in an Open Channel: An Experimental Investigation of Discharge and Coefficient of Discharge
Ruturaj Guru, Meghansh Somani, Apurva Shingane, and Govardhan Sale
Department of Civil Engineering, Vishwakarma Institute of Technology Pune, Maharashtra, India
Project Guide: Dr. Shreenivas Londhe | Open Channel Hydraulics | Academic Year 20262027
AbstractFlow over a hump is an open-channel hydraulic phenomenon in which a raised portion of the channel bed changes local water depth and velocity. This laboratory study investigates flow over a bed hump and estimates the coefficient of discharge by comparing the actual discharge, measured volumetrically, with the theoretical discharge calculated from the continuity equation and Bernoullis energy equation. The experiment used a rectangular tilting flume of width 0.076 m, a pointer gauge, a bed hump, and a collecting tank of plan dimensions 0.4 m × 0.4 m. A tank-level rise of 0.1 m corresponds to a collected volume of 0.016 m3. Upstream depth, depth over the hump, and collection time were recorded for seven runs. Recalculation from the transcribed readings gives an average coefficient of discharge of approximately 0.707; this result is provisional because some handwritten table entries differ from the recalculated values and should be checked against the original notebook. The measured depth over the hump was lower than the upstream depth in all seven runs. The study demonstrates the practical use of energy and continuity principles and highlights the influence of measurement uncertainty and idealizing assumptions on experimental discharge estimates.
Index Termsflow over hump, open-channel hydraulics, discharge, coefficient of discharge, specific energy, laboratory experiment.
-
Introduction
Open-channel flow is the movement of water through a channel whose free surface is exposed to atmospheric pressure. Rivers, canals, drainage channels, spillways, and laboratory flumes are common examples. The flow depends on discharge, channel geometry, water depth, velocity, bed slope, and energy conditions [1].
A hump is a raised section of the channel bed that changes the available flow depth and the local hydraulic conditions. As water passes over the raised section, depth and velocity adjust according to the continuity and energy relationships, so a hump provides a useful laboratory arrangement for examining the relationship between water depth, velocity head, and discharge.
In an idealized analysis, the energy equation is applied between an upstream section and a section at the hump crest. For a horizontal bed and negligible energy loss, the difference in flow depths is related to the difference in velocity heads. The continuity equation expresses velocity in terms of discharge and cross-sectional area, allowing the theoretical discharge to be calculated from measured depths. Actual laboratory flow may differ from this prediction because of friction, turbulence, local disturbances, non-uniform velocity distribution, and measurement uncertainty. The coefficient of discharge, defined
as the actual discharge divided by the theoretical discharge, provides a convenient comparison between the two.
The aim of this work is to investigate experimentally the flow of water over a hump in an open channel and to determine the coefficient of discharge. The specific objectives are (i) to understand the hydraulic behavior of water flowing over a raised channel bed; (ii) to measure the upstream depth and the depth over the hump under different flow conditions; (iii) to calculate the upstream and crest cross-sectional areas; (iv) to determine the actual discharge by the volumetric method; (v) to calculate the theoretical discharge using the continuity and Bernoulli energy equations; (vi) to determine the coefficient of discharge for each run; and (vii) to compare measured and theoretical discharge and identify possible sources of uncertainty.
-
Literature Review
The theoretical basis of flow over a hump comes from established open-channel hydraulics. Chow [1] presents the fundamental relationships among flow depth, velocity, energy, and channel geometry. These principles explain how a change in bed elevation can alter the available specific energy and the flow depth associated with a given discharge.
Subramanya [2] provides a further treatment of continuity, energy relationships, and flow regimes relevant to laboratory channel experiments. The continuity equation links discharge with cross-sectional area and mean velocity, while the energy equation relates depth and velocity head between selected sections.
The laboratory manual supplied for this experiment specifies a horizontal flume, depth measurements upstream and over the hump, volumetric discharge measurement, and calculation of the coefficient of discharge. This study follows that procedure and applies it to the seven completed runs in the supplied handwritten observation sheet. The discussion above is a concise theoretical review rather than a systematic review of individual journal articles; a final publication-oriented paper should add verified peer-reviewed studies on flow over bed humps, critical flow, and discharge measurement.
-
Theoretical Background
A. Continuity Equation
For steady flow with no significant lateral inflow or outflow, the discharge is constant between the upstream section
(1) and the hump crest (2):
Q = AlVl = A2V2 (1)
where Q is the discharge (m3/s), A is the cross-sectional area (m2), and V is the mean velocity (m/s). Hence V1 = Q/A1 and V2
= Q/A2.
B. Bernoullis Energy Equation
For the idealized case of a horizontal bed and negligible energy losses, the energy equation between the two sections is
TABLE I Experimental Parameters
Parameter Value
Flume width, B 0.076 m
Tank length 0.4 m
Tank width 0.4 m
Water-level rise in tank 0.1 m
Collected volume 0.016 m3 Completed runs in supplied sheet 7
B. Procedure
The hump was fixed securely on the floor of the tilting flume, and the flume bed slope was set to zero to provide a
V2 V2
y + l = y + 2
(2)
horizontal bed. The water supply was started, and a steady flow
was established using the control valve. The pointer gauge was
l 2g
2 2g
positioned upstream, away from the local drawdown region,
Substituting V1 = Q/A1 and V2 = Q/A2 from (1) and rearranging gives the theoretical discharge
Q = AlA2 J2g(y – y ) (3)
t l 2
A2 A2
and the upstream depth y1 was measured. The pointer gauge was then positioned at the centre of the hump, and the depth y2 was measured. Water was collected in the measuring tank, and the time for a 0.1 m rise in water level was recorded. The flow rate
l 2 was then varied and the measurements were repeated. Areas,
where y1 is the upstream depth, y2 is the depth over the hump, g
= 9.81 m/s2, and A1 and A2 are the respective flow areas. Equation (3) is appropriate only when the stated assumptions are reasonably satisfied.
C. Cross-Sectional Areas
For a rectangular channel of width B, A1 = By1 and A2 = By2.
actual discharge, theoretical discharge, and coefficient of discharge were calculated for each run.
The manual recommends 810 flow conditions; however, only seven completed runs were visible in the supplied handwritten record, so the present analysis uses those seven runs.
The flume width recorded in the manual is B = 0.076 m.
<>D. Actual Discharge by the Volumetric Method
A. Observations
-
Results and Discussion
The collecting tank has plan dimensions 0.4 m × 0.4 m, and the measured water-level rise is 0.1 m. The collected volume is therefore 0.4 × 0.4 × 0.1 = 0.016 m3, and the actual discharge is
Table II is a transcription of the supplied handwritten observation sheet. Because handwriting is not perfectly clear, the values should be checked against the original laboratory
Qact
= 0.0l6
t
(4)
notebook before final submission.
where t is the collection time in seconds.
E. Coefficient of Discharge
TABLE II
Run
y1 (m)
y2 (m)
t (s)
1
0.0285
0.0164
44.99
2
0.0275
0.0168
54.27
3
0.0264
0.0162
27.40
4
0.0256
0.0148
27.80
5
0.0270
0.0179
25.47
6
0.0273
0.0169
27.47
7
0.0257
0.0170
31.09
Transcribed Experimental Observations
C = Qact
d Qth
(5)
The coefficient of discharge is dimensionless and compares the measured actual discharge with the idealized theoretical estimate.
-
-
Experimental Setup and Methodology
-
Apparatus
The apparatus listed in the supplied laboratory manual comprises a tilting flume, a bed hump, an adjustable tailgate or sluice gate, a pointer gauge mounted on a trolley, a discharge- measuring tank, and a stopwatch. The channel width is 0.076
m. The measuring tank has plan dimensions 0.4 m × 0.4 m, and the collection time is measured for a 0.1 m rise in water level. The experimental parameters are summarized in Table I.
-
Sample Calculation (Run 1)
For Run 1, B = 0.076 m, y1 = 0.0285 m, y2 = 0.0164 m, t =
44.99 s, and g = 9.81 m/s2. The upstream area is A1 = 0.076 × 0.0285 = 2.166 × 103 m2, and the area over the hump is A2 =
0.076 × 0.0164 = 1.2464 × 103 m2. The actual discharge is Qact
= 0.016/44.99 = 3.556 × 104 m3/s. From (3), the theoretical discharge is Qth = 7.426 × 104 m3/s, so Cd = (3.556 × 104)/(7.426 × 104) = 0.479. The handwritten sample reports Cd = 0.486; the recalculation from the transcribed time and depths gives approximately 0.479. The discrepancy may arise
from rounding or from a different original input and should be verified.
-
Tabulated Calculations
All entries in Table III were recalculated from the transcribed depths, collection times, flume width, and tank volume. The average coefficient of discharge is Cd,avg = ( Cd)/7
0.707.
TABLE III Recalculated Discharge Results
Run
A1 (103
m2)
A2 (103
m2)
Qact (104 m3/s)
Qth (104
m3/s)
Cd
1
2.166
1.246
3.556
7.426
0.479
2
2.090
1.277
2.948
7.389
0.399
3
2.006
1.231
5.839
6.976
0.837
4
1.946
1.125
5.755
6.346
0.907
5
2.052
1.360
6.282
7.678
0.818
6
2.075
1.284
5.825
7.388
0.788
7
1.953
1.292
5.146
7.118
0.723
-
Variation in Depth
The upstream depths range from 0.0256 m to 0.0285 m, while the depths measured over the hump range from 0.0148 m to 0.0179 m. In all seven runs, the depth over the hump is lower than the upstream depth. This is consistent with the local influence of the raised bed, although depth data alone do not establish whether critical flow occurred.
-
Actual and Theoretical Discharge
The actual discharge was calculated by the volumetric method, whereas the theoretical discharge was calculated from the energy and continuity relationships. The actual discharge ranges from approximately 5.146 × 104 to 6.282 × 104 m3/s for Runs 37, with lower values of approximately 3.556 × 104 and 2.948 × 104 m3/s for Runs 1 and 2, respectively. The theoretical discharge ranges from approximately 6.346 × 104 to 7.678 × 104 m3/s.
For all seven runs, the theoretical discharge is higher than the actual discharge. This is consistent with the fact that the theoretical equation represents an idealized flow condition, while actual laboratory flow may be affected by energy losses and measurement uncertainty.
-
Coefficient of Discharge
The recalculated coefficient ranges from approximately
0.399 (Run 2) to 0.907 (Run 4), with a mean of approximately 0.707. The variation between runs indicates that the ratio of measured to theoretical discharge was not constant across the recorded conditions. These values should be treated as provisional until the handwritten readings and calculations have been verified.
-
Measurement Quality
Depth measurement errors affect both cross-sectional areas and the depth difference in the theoretical discharge equation, while timing errors directly affect the actual discharge. The mismatch between several handwritten values and the recalculated table reinforces the need to verify the raw data and intermediate arithmetic before reporting final results. The
current dataset does not independently establish critical flow or a hydraulic jump; additional velocity and depth analysis, or direct observation, would be needed to support such claims.
-
Limitations and Future Scope
-
Limitations
The study has the following limitations: (i) only seven completed runs were available, although the manual recommends 810 conditions; (ii) the exact hump geometry is not fully documented in the supplied observation sheet; (iii) the theoretical equation assumes negligible energy losses and idealized flow between sections; (iv) pointer-gauge readings and collection timing are subject to measurement uncertainty;
(v) some handwritten calculations differ from values recalculated from the transcribed observations; and (vi) no direct measurements of energy loss, velocity distribution, or critical-flow conditions were supplied.
-
Future Scope
Future work could (i) repeat the experiment for additional discharge conditions and replicate each measurement; (ii) test different hump heights and geometries; (iii) measure the water surface at additional positions along the flume; (iv) calculate the Froude number and specific energy at the upstream and crest sections where sufficient data are available; (v) investigate energy losses and the conditions for critical flow; and (vi) compare verified laboratory measurements with a numerical or theoretical model.
-
-
Conclusion
This laboratory investigation examined water flow over a hump in a rectangular open channel using depth measuements and volumetric discharge measurements. The flume width was
0.076 m, and the collecting-tank volume corresponding to a 0.1 m water-level rise was 0.016 m3. Seven completed runs were transcribed from the supplied observation sheet.
For each run, cross-sectional areas were calculated from the measured depths, the actual discharge was obtained from the collected volume and time, and the theoretical discharge was estimated using the continuity and Bernoulli energy relationships. The measured depth over the hump was lower than the upstream depth in all seven runs, and the recalculated theoretical discharge exceeded the actual discharge in every run.
The mean coefficient of discharge calculated from the transcribed observations was approximately 0.707, with individual values ranging from approximately 0.399 to 0.907. These results are provisional because some values in the handwritten calculation table differ from the recalculated values, and verification against the original notebook is necessary before the figures are treated as final. The experiment demonstrates the practical use of energy and continuity principles and the importance of careful measurement in open- channel hydraulics.
References
-
V. T. Chow, Open-Channel Hydraulics. New York, NY, USA: McGraw- Hill, 1959.
-
K. Subramanya, Flow in Open Channels. Tata McGraw-Hill Education.
