Finite Element Analysis of Different Types of FRP on Beam-Column Joint

DOI : 10.17577/IJERTV7IS050232

Download Full-Text PDF Cite this Publication

Text Only Version

Finite Element Analysis of Different Types of FRP on Beam-Column Joint

Arindom Bora1

4th sem, M.Tech. Structural Engineering

MVJ College of Engineering Bengaluru, Karnataka, India

Tejaswini M.L.2 Assistant Professor, Civil Engineering Dept.

MVJ College of Engineering, Bengaluru, Karnataka, India

Kiran S.M.3

Assistant Professor, Mechanical Engineering Dept.

MVJ College of Engineering, Bengaluru, Karnataka, India

Abstract In any type of building the most crucial element is the beam-column joint. In this study, the beam-column joint analysis is done using ANSYS. The design is first carried out in ETABS and using the design data it is analysed in ANSYS. The equivalent stresses and the total deformation generated in the beam-column joint is calculated. Due to the bad effects of environmental changes, pollution, carbonation, corrosion occurring in a structural element due to which the building is likely to collapse. The failure in the beam-column joint can occur due to these reasons and also due to lack of proper reinforcement in the joint region. While experiencing seismic activity with inadequate reinforcement the beam-column joint will fail. This project aims in introducing FRP in the beam column joints which are likely to fail by retrofitting it. The failure can be identified by observing cracks or carrying out NDT tests to find out the region of cracks and the amount of reinforcement corroded. In this study different types of FRP is introduced to the beam-column joint in ANSYS. It is7analysedfand then the equivalent stresses and total deformations generated5are compared with each other whichever will be more effective to be used in the field of construction.

KeywordsFinite Element Analysis, ANSYS, FRP

  1. INTRODUCTION

    In a framed structure, the load transfer mechanism takes place in the manner of loads from the slabs gets distributed to the beams, then the loads from beams get distributed to the columns and then the loads from columns to the footings which eventually transfers the loads to the ground surface. The junction of beam and column behaves as a crucial part during the action of seismic forces and it tends to fail if the detailing is not proper. The failure of a beam-column joint will result in the collapse of the structure. The joint of beam-column in a structure can be said as the weakest part of a structure. These joints are the important zones for transfer of forces and moments effectively between the subsequent connecting elements of beam and columns. The performance of a framed structure mostly depends upon the integrity of the joints for which the beam-column joints joint is a crucial part. The behaviour of the beam-column joint of a framed structure is being studied in this project. Upon the application of Fiber Reinforced Polymer (FRP) laminate in the beam-column joint, the behaviour is also studied. It is studied by doing Finite Element Analysis in ANSYS 14.5. The stresses and deformations are obtained as results from the analysis. The building is being designed using Etabs 2016.

    Types of Fiber Reinforced Polymer used in this study:

    • Carbon Fiber Reinforced Polymer.

    • Glass Fiber Reinforced Polymer.

    • Basalt Fiber Reinforced Polymer.

    • Aramid Fiber Reinforced Polymer

  2. ANALYSIS

    1. Analysis in ETABS

      For the analysis of the structure using ETABS 2016, a frame structure is taken into consideration. The frame structure has the dimension of 15m*19m having a storey height of 3.5m at first floor and 3.2m for the subsequent 4 floors. A depth of 1.5m is assumed for the foundation below the ground level.

      Material properties used: Grade of Concrete= M30 Grade of Steel= Fe415

      Details of the dimension of the structural elements used:

      Main beam, B1= 300*500mm Secondary beam, B2= 300*400mm Plinth beam, B3= 300*400mm Column, C1= 300*500mm Column, C2= 400*400mm Column, C3= 400*500mm

      Slab thickness= 125mm

      Storey height= 3.5m (First floor)

      = 3.2m (Other floors)

      The beam-column joint to be analyzed is the connection between B29 and C2. The beam is in the first floor.

      Loads:

      At all floors masonry load due to main beam= 11.96 kN/m

      At all floors masonry load due to Secondary beam=12.42kN/m At ground floor masonry load due to main beam= 13.34 kN/m At ground floor masonry load due to Secondary beam= 13.8 kN/m

      Shell loads applied as:

      At the roof Live load= 1.5kN/m²

      At the other floors Live load= 3kN/m² [18]

      Taking the moments and axial forces from ETABS, calculating the reinforcements manually the following results are obtained:

      Reinforcement for Beam: Main bar diameter= 16mm Number of bars=2

      Anchor bar diameter= 10mm

      Number of bars= 2

      Provide 2 legged 8mm diameter stirrups with spacing of 260mm c/c.

      Reinforcement for Column: Number of bars= 5 Diameter of Bars= 20mm

      Fig.1: Combined Bending Moment diagram of the beam B29 and column C2 at first floor and second floor

    2. Analysis in ANSYS

      In this study, 5 different models are created in ANYS. They are: Beam-Column joint with reinforcement. Beam-Column joint with reinforcement and Carbon FRP. Beam-Column joint with reinforcement and Glass FRP (S2 Glass). Beam-Column joint with reinforcement and Basalt FRP. Beam-Column joint with reinforcement and Aramid FRP (Kevlar 49).

      For the modelling part the length of the column considered is= 3.35m. (half of the centre to centre distance between the column heights has been assumed). And the length of the beam is= 3.7m

      Fig. 2: Beam-Column joint with reinforcement modelled in ANSYS

      The modelling of the 4 different types of FRP is also done in the same way with a thickness of 9.9mm of FRP applied in all the types. It is considered that the FRP has an uniform thickness of 1.1mm and 9 layers have been applied.

      Fig. 3: Application of FRP in the beam-column joint

      In the fig. 2 it can be seen that the FRP has been applied to the beam column joint in the area where the stress concentration is more which is considered as 400mm in below and top from the face of the column vertically and 1000mm in below and top horizontally. The length of the application of FRP is same throughout all other FRP.

      Fig.4: Meshed model of the Beam-Column joint

      Fine mesh property is being used and the size of the mesh is selected as default.

      Fixed support conditions are applied at the free ends of the beam and column.

      The load applied on the beam is applied as pressure load.

      The pressure loads applied are as follows: Pressure acting as slab load= 0.0321Mpa Pressure acting as wall load= 0.046 Mpa

      The same wall load and slab load is applied through all the 5types of analysis performed: without FRP, with CFRP, with GFRP, with BFRP and with AFRP.

  3. RESULTS

      1. Equivalent stress:

        Fig 5: Slab load is applied in the form of Ramped Pressure on the beam

        Fig. 6: Wall load is applied in the form of Ramped Pressure on the beam

        SOLID 65 element is used for concrete structural rectangular or block. It is assigned to define the property of concrete. LINK 180 is used to define the property of reinforcement. SOLID 64 element is used to define the FRP layer on concrete.

        Properties of different types of FRP used:

        86.9 GPa

        NAME

        YOUNGS MODULUS

        POISSONS RATIO

        CARBON [15,3]

        76.35GPa

        0.26

        GLASS (S2 GLASS)

        [8]

        0.22

        BASALT [16]

        89 GPa

        0.2

        ARAMID (KEVLAR

        49)[17]

        151.7 GPa

        0.35

        The results obtained from the equivalent stress can be summarized as:

        • The equivalent stress for concrete without FRP is 1.2047 MPa

        • The equivalent stress for concrete with CFRP is 0.61384 MPa

        • The equivalent stress for concrete with GFRP is 0.61263 MPa

        • The equivalent stress for concrete with BFRP is 0.6124 MPa

        • The equivalent stress for concrete with AFRP is 0.60545 Mpa

          Fig 7: Equivalent stress in concrete without FRP

          Fig 8: Equivalent stress in concrete with CFRP

          Fig. 9: Equivalent stress in concrete with GFRP

          Fig. 10: Equivalent stress in concrete with BFRP

          Fig. 11: Equivalent stress in concrete with AFRP

      2. Total Deformation:

        The results obtained after analyzing for total deformation are as follows:

          • The total deformation on concrete without FRP is 0.11372 mm

          • The total deformation on concrete with CFRP is 0.44181 mm

          • The total deformation on concrete with GFRP is 0.38282 mm

          • The total deformation on concrete with BFRP is 0.37043 mm

          • The total deformation on concrete with AFRP is 0.22815 mm

        Fig. 12: Total deformation in the beam-column joint with reinforcement

        Fig. 13: Total deformation in the beam-column joint with CFRP

  4. CONCLUSIONS

    A comparison between the results obtained are shown below:

    50

    0

    40.596

    0 1.2047

    0

    .61384

    .61263

    0.6124

    0

    .60545

    44.426

    45

    45.716 46.29

    EQUIVALENT STRESS, MPa

    40

    35

    30

    25

    20

    15

    Fig. 14: Total deformation in the beam-column joint with GFRP

    10

    5

    0

    Without FRP CFRP GFRP BFRP AFRP

    MATERIAL TYPES

    ON FRP WHOLE SPECIMEN

    Fig. 15: Total deformation in the beam-column joint with BFRP

    Fig. 16: Total deformation in the beam-column joint with AFRP

    Fig 17: Comparison of equivalent stress obtained for different material

    0.22815

    0.37043

    0.38282

    0.44181

    0.5

    0.45

    0.4

    0.35

    0.3

    0.25

    0.2

    DISPLACEMENT, mm

    types

    Without CFRP GFRP BFRP AFRP

    FRP

    MATERIAL TYPES

    ON FRP

    WHOLE SPECIMEN

    0.029554 0.026578 0.025944 0.019307

    0

    0.11372

    0.15

    0.1

    0.05

    0

    Fig 18: Comparison of total deformation obtained for different material types

    From the results, it can be concluded that upon using the different types of FRPs the equivalent stresses in the concrete got reduced. The reduction is basically due to the fact that the FRP is acting like an external reinforcement to the beam- column joint and the stresses generated is taken by the FRPs. Different types of FRPs have different modulus of elasticity and different Poissons ratio. Therefore, the variation is observed. The maximum equivalent stress is generated at the junction of the FRP and the beam of the beam-column joint because of the fact that the load applied on the beam is counteracted by the FRP and at the end point of the FRP the stresses are concentrated.

    While observing at the total deformation, it can be concluded that the total deformation is lower when there is no use of FRP due to the fact that when FRP is used in the structure, the total load applied on the structure is taken up by the FRP used which results in maximum deformation in the FRP used specimen. Therefore, FRP helps to take up the load applied on concrete and reinforcement and it counteracts it. So, at the junction of beam-column joint it can be observed that the maximum deformation is occurring at the junction of the FRP and the beam of the beam-column joint.

  5. ACKNOWLEDGMENT

This paper is based on the work carried out by me (Arindom Bora), as part of my PG course, under the guidance of Tejaswini M.L. (Assistant Professor, MVJ College of Engineering) and Kiran S.M. (Assistant Professor, MVJ College of Polytechnic). The fruitful interactions held with my guides during my project are duly acknowledged.

REFERENCES

      1. Zhishen Wu, Xin Wang and Gang Wu on Basalt FRP Composite as Reinforcements in Infrastructure in 17th Annual International Conference on Composites/Nano Engineering (ICCE-17). 21-24.

      2. Nagumalli Kedar Nath & T. M. Jeyashree on Analytical study on reinforced concrete beam column joint wrapped with CFRP in International Journal of Advanced Structures and Geotechnical Engineering, Vol. 05, No. 02, 2016

      3. Jijin V & Preetha Prabhakaran on Effect of GFRP Jacketing & CFRP Jacketing on RC Columns of Different Cross-Sectional Shapes in IOSR Journal of Mechanical and Civil Engineering, 2016

      4. Anusree Lal on Analysis of Exterior Beam Column Joint Using ANSYS in International Journal of Science and Research Volume 5 Issue 7, July 2016

      5. Shabana T S, Dr. K.A Abubaker, Renny Varghees on Finite Element Analysis of Beam Column Joint with GFRP under Dynamic Loading in International Journal of Engineering Trends and Technology (IJETT), Volume 28 Number 8, 2015

      6. Fareed Elgabbas, Ehab A. Ahmed and Brahim Benmokrane on Physical and mechanical characteristics of new basalt- FRP bars for reinforcing concrete structures in Construction and Building Materials, 95, 2015

      7. Kaliluthin.A.K. & Kothandaraman.S on Experimental investigation on behavior of reinforced concrete beam- column Joint In International Journal of Civil and Structural Engineering, Volume 4, No 3, 2014

      8. Sathish Kumar T P, Naveen J. and S Satheeshkumar on Glass fiber-reinforced polymer composites A review in Journal of Reinforced Plastics and Composites, 2014

      9. Mehmet Mustafa Önal on Strengthening Reinforced Concrete Beams with CFRP and GFRP in Advances in Materials Science and Engineering, 2014

      10. Asst. Prof. Anumol Raju & Asst. Prof. Liji Anna Mathew on Retrofiiting of RC Beams using FRP in International Journal of Engineering Research & Technology, Volume 2,

        Issue 1, 2013

      11. T.Manikandan. G.Balaji Ponraj, in Strengthening Of RC Beam Using GFRP Wraps on International Journal of Engineering Trends and Technology (IJETT) –

        Volume4,Issue5- May 2013

      12. Robert Ravi.S & Prince Arulraj.G on Experimental Investigation on Behavior of Reinforced Concrete Beam Column Joints Retrofitted with GFRPAFRP Hybrid Wrapping in International Journal of Civil and Structural Engineering, Volume 1, No 2, 2010

      13. Hannibal Ólafsson & Eyþór Þórhallsson on Basalt fiber bar in Bsalt fiber Seminar, Reykjavik University, 2009

      14. V.M. karbhari, J.W. Chin, D. Hunston, B. Benmokrane, T. Juska, R. Morgan, J. J. Lesko, U. Sorathia and D. Reynaud on Durability Gap Analysis for Fiber-Reinforced Polymer Composites in Civil Infrastructure in Journal of Composites for Construction, 2003

      15. Richard D. Iacobucci, Shamim A. Sheikh and Oguzhan Bayrak on Retrofit of Square Concrete Columns with Carbon Fiber-Reinforced Polymer for Seismic Resistance in ACI Structural Journal, V. 100, No. 6, November- December 2003.

      16. Ali Nawaz Mengal, Saravanan Karuppanan and Azmi Abdul Wahab on Structural Analysis of Basalt Fiber Reinforced Plastic Wind Turbine Blade in MATEC Web of Conferences 13, 2014

      17. K.K. Herbert Yeung and K.P. Rao, on Mechanical Properties of Kevlar-49 Fibre Reinforced Thermoplastic Composites in Polymers & Polymer Composites, Vol. 20,

        No. 5, 2012

      18. IS 875(Part 1)- 1987, Code of Practice for Design Loads (Other Than Earthquake) for Buildings and Structures

Leave a Reply