šŸ”’
Global Research Press
Serving Researchers Since 2012

Removal of Pharmaceutical of Emerging Contaminants (Pharmaceuticals) Using Advanced Oxidation Process (Fenton Process)

DOI : 10.5281/zenodo.20472514
Download Full-Text PDF Cite this Publication

Text Only Version

Removal of Pharmaceutical of Emerging Contaminants (Pharmaceuticals) Using Advanced Oxidation Process (Fenton Process)

Removal of Pharmaceutical of Emerging Contaminants (Pharmaceuticals) Using Advanced Oxidation Process (Fenton Process)

Sukanya Kadam (1), Laxmi Gupta (2), Dilip Budhlani (3), Manthan Banerjee (4)

PG Scholer (1), Assistant Professor (2), Assistant Professor (3), Assistant Professor (4)

Department of Civil Engineering

Swaminarayan Siddhanta Institute of Technology, Nagpur (MH)

Abstract : The continuous discharge of pharmaceutical compounds into aquatic environments has become a serious environmental concern due to their persistence, bioaccumulation potential, and ecological toxicity. Conventional wastewater treatment plants are not fully effective in removing pharmaceutical micropollutants such as antibiotics, analgesics, and antiparasitic compounds. This study investigates the application of the Fenton Process (Fe²/HO) for degradation and mineralization of pharmaceutical contaminants present in clinic greywater collected from Nagpur.

Greywater samples were collected from selected discharge points near Shraddha Clinic, Rameshwari-Manewada region. The collected wastewater was characterized for pH, COD, TOC, turbidity, conductivity, and pharmaceutical concentration using LC-MS/HPLC techniques. The study focused on degradation of selected pharmaceuticals including Enrofloxacin, Oxytetracycline, and Albendazole.

Experimental optimization was performed by varying pH, Fe² dosage, hydrogen peroxide concentration, and reaction time. The Fenton process showed maximum degradation under acidic conditions around pH 3.

+ + + + +

Under optimized conditions, COD removal efficiency reached 8993%, TOC reduction reached 7482%, and pharmaceutical degradation exceeded 95% for most target compounds.

Economic analysis indicated that the Fenton process is technically feasible for tertiary wastewater treatment with an estimated operational cost of 3858/m³ depending on reagent consumption. The study concludes that the Fenton process can serve as an efficient and scalable treatment method for removal of pharmaceutical emerging contaminants from greywater systems.

Keywords:

Fenton Process, Pharmaceutical Contaminants, Greywater Treatment, Advanced Oxidation Process, Hydroxyl Radicals, COD Removal, TOC Reduction, Wastewater Treatment, Emerging Pollutants

  1. INTRODUCTION:

    Pharmaceutical compounds are increasingly detected in aquatic environments due to rapid urbanization, healthcare activities, and improper disposal practices. Antibiotics, anti-inflammatory drugs, hormones, and antiparasitic compounds are continuously introduced into wastewater systems through domestic sewage, hospital discharge, and pharmaceutical waste streams. These compounds are categorized as emerging contaminants because their environmental occurrence and ecological impacts are not completely regulated or understood.

    In urban regions such as Nagpur, wastewater generated from clinics and healthcare facilities contains significant

    concentrations of pharmaceutical residues. Conventional wastewater treatment systems are primarily designed for removal of biodegradable organic matter and suspended solids; however, they are ineffective for complete degradation of complex pharmaceutical molecules.

    Advanced Oxidation Processes (AOPs) are considered promising treatment technologies because they generate highly reactive hydroxyl radicals capable of oxidizing refractory organic compounds into simpler and less toxic products. Among various AOPs, the Fenton process is widely studied due to its simplicity, high oxidation potential, low equipment requirement, and rapid degradation efficiency. The Fenton process involves catalytic

    decomposition of hydrogen peroxide in the presence of ferrous ions under acidic conditions, producing hydroxyl radicals.

    2+ + 22 3+ + +

    The generated hydroxyl radicals attack pharmaceutical molecules non-selectively, leading to degradation and mineralization.

    The present study focuses specifically on optimization and evaluation of the Fenton process for removal of pharmaceutical contaminants from clinic greywater.

  2. PROBLEM STATEMENT:

Clinic greywater may contain pharmaceutical residues, disinfectants, organic matter, and other pollutants. In many small healthcare facilities, this wastewater is directly discharged into municipal drains without advanced treatment. Conventional treatment systems are not designed to completely degrade pharmaceutical contaminants.

If untreated pharmaceutical-contaminated greywater is continuously discharged into the environment, it may cause groundwater contamination, aquatic toxicity, antibiotic resistance, and long-term ecological imbalance. Therefore, there is a need for a simple, low-cost, and effective treatment process that can be applied at small healthcare facilities.

The Fenton process can be used as a tertiary treatment method because it requires simple chemicals, produces strong oxidizing radicals, and can be operated at laboratory or small field scale.

.3. AIM AND OBJECTIVES:

    1. Aim

      To evaluate and optimize the Fenton process for removal and mineralization of pharmaceutical emerging contaminants from clinic greywater.

    2. Objectives

  1. To collect and characterize clinic greywater for pH, COD, TOC, turbidity, conductivity, and pharmaceutical concentration.

  2. To study the removal of Enrofloxacin, Oxytetracycline, and Albendazole using the Fenton process.

  3. To optimize pH, Fe² dosage, HO dosage, and reaction time.

  4. To evaluate COD removal and TOC reduction after treatment.

  5. To study the degradation kinetics of selected pharmaceutical contaminants.

  6. To estimate the treatment cost of the Fenton process.

  7. To assess the suitability of the process for small-scale healthcare wastewater treatment.

    1. MATERIALS AND METHODS

      1. Study Area and Sample Collection

        Greywater samples were collected from selected discharge points near Shraddha Clinic, RameshwariManewada region, Nagpur, Maharashtra, India. Samples were collected using the grab sampling method. Amber glass bottles were used for sample collection to reduce the effect of light on pharmaceutical compounds.

        After collection, samples were stored in an ice box and transported to the laboratory for analysis. The samples were analyzed within a short time to avoid changes in wastewater characteristics.

      2. Chemicals Used

        The following chemicals were used in the study:

        6

        Sr.

        No.

        Chemical & Material

        Purpose

        1

        Ferrous sulphate

        Source of Fe² catalyst

        2

        Hydrogen peroxide

        Oxidizing agent

        3

        Dilute sulphuric acid / hydrochloric acid

        pH adjustment

        4

        Sodium hydroxide

        Neutralization after treatment

        5

        Distilled water

        Preparation of solutions

        Greywater sample

        Wastewater to be treated

      3. Target Pharmaceutical Compounds

        Sr. No.

        Pharmaceutical Compound

        Type / Class

        1

        Enrofloxacin

        Antibiotic

        2

        Oxytetracycline

        Antibiotic

        3

        Albendazole

        Antiparasitic drug

        Parameter

        Method / Instrument

        pH

        Digital pH meter

        COD

        Closed reflux method

        TOC

        TOC analyzer

        Turbidity

        Turbidity meter

        Conductivity

        Conductivity meter

        Pharmaceutical concentration

        HPLC / LC-MS

        Sludge volume

        Settling cone / measuring cylinder

      4. Analytical Methods

      5. Experimental Setup

        Batch experiments were performed using a 1 L glass reactor or borosilicate beaker. A working volume of 500 mL greywater sample was used for each experimental run. The sample was continuously mixed using a magnetic stirrer. The reaction was carried out under dark conditions to avoid light interference.

        The pH of the sample was first adjusted to the required value. After that, ferrous sulphate was added as the Fe² source, followed by hydrogen peroxide addition. Samples were collected at fixed time intervals for analysis.

        Figure 1: Laboratory setup for pH testing

      6. Experimental Conditions

        Parameter

        Range Studied

        pH

        2, 3, 4, 5, 7

        Fe² dosage

        1050 mg/L

        HO dosage

        100500 mg/L

        Reaction time

        0120 min

        Working volume

        500 mL

        Stirring speed

        150 rpm

      7. Treatment Procedure

        1. Collect clinic greywater sample.

        2. Analyze initial pH, COD, TOC, turbidity, conductivity, and pharmaceutical concentration.

        3. Take 500 mL sample in a glass reactor.

        4. Adjust pH to the required value.

        5. Add required Fe² dosage.

        6. Add required HO dosage.

        7. Stir the sample continuously under dark conditions.

        8. Collect samples at 0, 15, 30, 60, 90, and 120 minutes.

        9. Analyze treated samples for COD, TOC, turbidity, and pharmaceutical concentration.

        10. Calculate removal efficiency and treatment cost.

      8. Removal Efficiency Formula

        Removal efficiency was calculated using the following equation:

        Removal Efficiency (%) = [(Ci Cf) / Ci] Ɨ 100

        Where:

        Ci = Initial concentration Cf = Final concentration

      9. Kinetic Analysis

        The degradation of pharmaceutical compounds was studied using pseudo-first-order kinetics.

        ln(C/C) = kt

        Where:

        C = Initial concentration C = Concentration at time t

        k = First-order rate constant t = Reaction time

      10. Statistical Analysis

        All experiments were performed in triplicate, and the average values were used for result analysis. Microsoft Excel was used for calculation of removal efficiency, preparation of graphs, and kinetic plotting. Linear regression was used to determine the kinetic rate constant and R² value. Statistical significance may be tested using one-way ANOVA at p < 0.05.

    2. Results and Discussion

      1. Initial Characteristics of Clinic Greywater

        The collected greywater sample showed high organic load and detectable pharmaceutical contamination.

        Parameter

        Unit

        Initial Value

        pH

        7.42

        COD

        mg/L

        1180

        TOC

        mg/L

        425

        Turbidity

        NTU

        326

        Conductivity

        µS/cm

        1915

        Enrofloxacin

        mg/L

        18.4

        Oxytetracycline

        mg/L

        14.2

        Albendazole

        mg/L

        9.6

        Table 1. Initial characteristics of clinic greywater

        2500

        2000

        1500

        1000

        500

        0

5.3 Effect of Fe² Dosage

Fe² acts as a catalyst in the Fenton reaction. The effect of Fe² dosage was studied from 10 to 50 mg/L.

Fe² Dosage (mg/L)

COD Removal (%)

10

68.4

20

84.7

30

92.4

40

90.2

50

86.5

Table 3. Effect of Fe² dosage on COD removal

Figure 2: Bar graph showing initial wastewater characteristics.

The initial COD and TOC values indicate the presence of significant organic pollutants in clinic greywater. The detection of Enrofloxacin, Oxytetracycline, and Albendazole confirms the presence of pharmaceutical contaminants.

      1. Effect of pH on COD Removal

        pH plays an important role in the Fenton process because hydroxyl radical generation depends on acidic conditions.

        Table 2. Effect of pH on COD removal

        pH

        COD Removal (%)

        2

        84.6

        3

        92.4

        4

        87.8

        5

        73.5

        7

        51.2

        100

        84.6

        92.4

        87.8

        73.5

        50

        51.2

        0

        2

        3

        4

        5

        7

        COD Removal (%)

        Maximum COD removal of 92.4% was observed at pH 3. At pH 3, Fe² remains active and hydrogen peroxide decomposition produces more hydroxyl radicals. At higher pH, iron may precipitate as ferric hydroxide, reducing the oxidation efficiency.

        Figure 3: Line graph showing effect of pH on COD removal.

        COD removal increased with Fe² dosage up to 30 mg/L. Further increase in Fe² dosage slightly reduced the efficiency. This may be due to excess Fe² consuming hydroxyl radicals and increasing sludge generation.

        100

        84.7 92.4 90.2 86.5

        68.4

        50

        0

        10

        20

        30

        40

        50

        COD Removal (%)

        Figure 4: Line graph showing Fe² dosage versus COD removal.

          1. Effect of HO Dosage

            Hydrogen peroxide is the main oxidizing agent in the Fenton process. The effect of HO dosage was studied from 100 to 500 mg/L.

            Table 4. Effect of HO dosage on COD removal

            /tr>

            HO Dosage (mg/L)

            COD Removal (%)

            100

            64.8

            200

            82.6

            300

            92.4

            400

            91.1

            500

            88.3

            The optimum HO dosage was 300 mg/L. At lower dosage, hydroxyl radical generation was insufficient. At higher dosage, excess hydrogen peroxide may act as a radical scavenger, reducing treatment efficiency.

            100

            82.6

            92.4

            91.1 88.3

            64.8

            50

            0

            100 200 300 400 500

            COD Removal (%)

            Figure 6: Line graph showing COD Concentration versus Reaction Time

            5.6 TOC Reduction and Mineralization

            TOC reduction was used to evaluate mineralization of organic pollutants.

            Figure 5: Line graph showing HO dosage versus COD removal.

          2. COD Reduction with Reaction Time

        The effect of reaction time was studied from 0 to 120 minutes.

        Table 5. COD reduction with reaction time

        Time (min)

        COD (mg/L)

        COD Removal (%)

        0

        1180

        0

        15

        835

        29.2

        30

        560

        52.5

        60

        248

        79.0

        90

        126

        89.3

        120

        90

        92.4

        COD concentration decreased from 1180 mg/L to 90 mg/L after 120 minutes. Rapid reduction was observed during the first 60 minutes, indicating fast oxidation of easily degradable organic compounds. After 90 minutes, the reduction rate became slower.

        Table 6: COD Reduction with Reaction Time Using Fenton Process

        Time (min)

        COD Concentration (mg/L)

        COD Removal (%)

        0

        1180

        0.0

        15

        835

        29.2

        30

        560

        52.5

        60

        248

        79.0

        90

        126

        89.3

        120

        90

        92.4

        Table 6. TOC reduction with reaction time

        Time (min)

        TOC (mg/L)

        TOC Reduction (%)

        0

        425

        0

        15

        318

        25.2

        30

        228

        46.4

        60

        138

        67.5

        90

        104

        75.5

        120

        86

        79.8

        600

        400

        200

        0

        0

        15 30 60 90 120

        TOC (mg/L)

        TOC Reduction (%)

        TOC concentration decreased from 425 mg/L to 86 mg/L after 120 minutes. The 79.8% TOC reduction indicates significant mineralization of pharmaceutical contaminants and organic matter.

        Figure 7: TOC reduction with reaction time.

          1. Pharmaceutical Degradation Efficiency

            The optimized Fenton conditions were pH 3, Fe² dosage of 30 mg/L, HO dosage of 300 mg/L, and reaction time of 120 minutes.

            2000

            1000

            0

            0

            15 30

            60

            Time

            90 120

            COD Concentration (mg/L)

            COD Removal (%)

            Table 7. Pharmaceutical degradation under optimized conditions

            Compound

            Initial Concentratio

            n (mg/L)

            Final Concentratio

            n (mg/L)

            Remova l (%)

            Enrofloxacin

            18.4

            0.52

            97.2

            Oxytetracyclin e

            14.2

            0.62

            95.6

            Albendazole

            9.6

            0.69

            92.8

            The Fenton process achieved more than 92% degradation for all selected pharmaceutical compounds. Enrofloxacin showed the highest removal efficiency, followed by Oxytetracycline and Albendazole.

            Albendazole

            Oxytetracycline Enrofloxacin

            0

            50 100 150

            Removal (%) Final Concentration (mg/L) Initial Concentration (mg/L)

            Table 9. Kinetic data for pharmaceutical degradation

            Time (min)

            Enrofloxacin ln(C/C)

            Oxytetracycline ln(C/C)

            Albendazole ln(C/C)

            0

            0.000

            0.000

            0.000

            15

            0.612

            0.554

            0.421

            30

            1.236

            1.108

            0.876

            60

            2.184

            1.965

            1.654

            90

            2.921

            2.742

            2.223

            120

            3.566

            3.132

            2.632

            Figure 8: Bar graph showing pharmaceutical degradation efficiency.

          2. Turbidity and Conductivity Reduction

            The Fenton process also improved the physical quality of greywater.

            Table 8. Physical water quality improvement

            Parameter

            Initial Value

            Final Value

            Removal / Change (%)

            Turbidity

            326

            NTU

            27.4 NTU

            91.6

            Conductivity

            1915

            µS/cm

            1632

            µS/cm

            14.8

            pH after neutralisation

            7.42

            7.10

            Within acceptable range

            100

            80

            60

            40

            20

            0

            Turbidity Conductivity pH after

            neutralisation

            Initial Value Final Value Removal / Change (%)

Turbidity reduction indicates the removal of suspended and colloidal matter. Conductivity reduction was comparatively lower because dissolved ions may remain in treated water after oxidation.

Figure 9: Before and after comparison of turbidity and conductivity.

    1. Kinetic Analysis

      Pseudo-first-order kinetic analysis was carried out for the selected pharmaceutical compounds.

      Table 10. Pseudo-first-order kinetic constants

      Compound

      Rate Constant, k (min¹)

      R²

      Enrofloxacin

      0.0294

      0.982

      Oxytetracycline

      0.0261

      0.976

      Albendazole

      0.0218

      0.961

      The R² values above 0.96 indicate that the degradation of pharmaceutical compounds followed pseudo-first-order kinetics. Enrofloxacin showed the highest rate constant, indicating faster degradation compared to Oxytetracycline and Albendazole.

    2. Cost Estimation

The treatment cost was estimated based on chemical consumption, pH adjustment, electricity, and sludge handling.

Table 11. Estimated operational cost of Fenton treatment

Cost Component

Estimated Cost (/m³)

Ferrous sulphate

10.514.8

Hydrogen peroxide

19.526.2

pH adjustment chemicals

4.06.5

Electricity

3.55.2

Sludge handlin

4.04.1

Total cost

41.556.8

The estimated treatment cost ranged from 41.5 to 56.8 per m³. This indicates that the Fenton process is economically feasible as a tertiary treatment process for small healthcare wastewater systems.

4.05

4.35

12.65

5.25

22.85

Ferrous sulphate

Hydrogen peroxide

pH adjustment chemicals

Electricity

Sludge handling

7. ENVIRONMENTAL SIGNIFICANCE

The Fenton process can be used as a decentralized treatment option for small clinics and healthcare facilities. It can reduce pharmaceutical discharge into the environment and help minimize the risk of antibiotic resistance and aquatic toxicity.

The treated water may be suitable for non-potable reuse after proper neutralization, filtration, and safety testing. The process can also be integrated with existing primary treatment systems.

Major environmental benefits include:

Figure 10: Pie chart showing cost distribution.

    1. DISCUSSION

      The results show that the Fenton process is effective for the removal of pharmaceutical contaminants and organic matter from clinic greywater. Maximum COD removal was obtained at pH 3. This is because acidic conditions support the catalytic reaction between Fe² and HO and improve hydroxyl radical generation.

      The optimum Fe² dosage was 30 mg/L. At lower dosage, hydroxyl radical production was insufficient. At higher dosage, excess Fe² may consume hydroxyl radicals and increase sludge formation. Similarly, the optimum HO dosage was 300 mg/L. Excess hydrogen peroxide may reduce the process efficiency because it can act as a radical scavenger.

      COD removal of 92.4% and TOC reduction of 79.8% indicate that the Fenton process not only reduced organic load but also mineralized a major portion of organic pollutants. Pharmaceutical degradation exceeded 92% for all selected compounds, confirming strong oxidation capability of the process.

      The kinetic analysis confirmed pseudo-first-order behavior. This indicates that pharmaceutical degradation rate depends on contaminant concentration and hydroxyl radical availability. The higher rate constant for Enrofloxacin indicates faster degradation compared to Oxytetracycline and Albendazole.

      The cost analysis shows that the process is feasible for small-scale applications. The main cost contribution was hydrogen peroxide, followed by ferrous sulphate and pH adjustment chemicals. The process can be further improved by optimizing chemical dosage, using solar-assisted Fenton treatment, or combining Fenton with filtration or adsorption.

      1. Reduction of pharmaceutical contaminants.

      2. Reduction of COD and TOC load.

      3. Lower risk of antimicrobial resistance.

      4. Improvement in greywater quality.

      5. Application in small healthcare units.

      6. Potential use as tertiary treatment before discharge.

  1. LIMITATIONS OF THE STUDY

    This study was conducted at laboratory scale using batch experiments. Field-scale performance may vary depending on wastewater flow rate, seasonal changes, pollutant concentration, chemical cost, and sludge management requirements. The study focused on three selected pharmaceutical compounds only. Future studies should include more contaminants, toxicity testing, and pilot-scale validation.

  2. CONCLUSION

    The present study evaluated the performance of the Fenton process for removal of pharmaceutical emerging contaminants from clinic greywater. The collected greywater showed high COD, TOC, turbidity, and detectable concentrations of Enrofloxacin, Oxytetracycline, and Albendazole.

    The optimum treatment conditions were pH 3, Fe² dosage of 30 mg/L, HO dosage of 300 mg/L, and reaction time of 120 minutes. Under these conditions, COD removal reached 92.4%, TOC reduction reached 79.8%, turbidity reduction reached 91.6%, and pharmaceutical degradation exceeded 92%.

    Kinetic analysis confirmed pseudo-first-order degradation behavior with R² values above 0.96. The estimated treatment cost ranged from 41.5 to 56.8/m³, indicating that the process is economically feasible for small-scale healthcare greywater treatment.

    Overall, the Fenton process is a simple, effective, low-cost, and scalable treatment method for pharmaceutical-contaminated greywater. It can be used as a tertiary

    treatment option for clinics, hospitals, and decentralized wastewater treatment systems.

  3. FUTURE SCOPE

    1. Pilot-scale continuous-flow Fenton reactor development.

    2. Integration of Fenton with UV or solar photo-Fenton treatment.

    3. Toxicity assessment of treated water.

    4. Identification of intermediate degradation products.

    5. Sludge minimization and iron recovery.

    6. Hybrid treatment using Fenton followed by activated carbon filtration.

    7. Application of AI-based chemical dose optimization.

    8. Field-scale validation at small healthcare facilities.

  4. REFERENCES

  1. Samal, K., Mahapatra, S., & Ali, M. H. (2022). Pharmaceutical wastewater as emerging contaminants: Treatment technologies, impact on environment and human health. Energy Nexus, 6, 100076.

  2. Pignatello, J. J., Oliveros, E., & MacKay, A. (2006). Advanced oxidation processes for organic contaminant destruction based on the Fenton reaction and related chemistry. Critical Reviews in Environmental Science and Technology, 36(1), 184.

  3. Neyens, E., & Baeyens, J. (2003). A review of classic Fentons peroxidation as an advanced oxidation technique. Journal of Hazardous Materials, 98(13), 3350.

  4. Homem, V., & Santos, L. (2011). Degradation and removal methods of antibiotics from aqueous matrices: A review. Journal of Environmental Management, 92(10), 23042347.

  5. Kümmerer, K. (2009). Antibiotics in the aquatic environment: A review. Chemosphere, 75(4), 417434.

  6. Oller, I., Malato, S., & SƔnchez-PƩrez, J. A. (2011). Combination of advanced oxidation processes and biological treatments for wastewater decontamination. Science of the Total Environment, 409(20), 41414166.

  7. Luo, Y., Guo, W., Ngo, H. H., Nghiem, L. D., Hai, F. I., Zhang, J., Liang, S., & Wang, X. C. (2014). A review on occurrence of micropollutants in aquatic environment and their fate during wastewater treatment. Science of the Total Environment, 473474, 619641.

  8. Verlicchi, P., Al Aukidy, M., & Zambello, E. (2012). Occurrence of pharmaceutical compounds in urban wastewater and removal after secondary treatment. Science of the Total Environment, 429, 123155.

  9. Michael, I., Frontistis, Z., Fatta-Kassinos, D., & Dionysiou, D. D. (2013). Fenton and photo-Fenton oxidation of antibiotics in wastewater. Water Research, 47(15), 56755686.

  10. Bautitz, I. R., & Nogueira, R. F. P. (2007). Degradation of tetracycline by photo-Fenton process. Journal of Photochemistry and Photobiology A: Chemistry, 187(1), 3339.

  11. Dantas, R. F., Contreras, S., Sans, C., & Esplugas, S. (2008). Sulfamethoxazole abatement by ozonation. Journal of Hazardous Materials, 150(3), 790794.

  12. Elmolla, E. S., & Chaudhuri, M. (2010). Degradation of amoxicillin, ampicillin and cloxacillin antibiotics by Fenton and photo-Fenton processes. Journal of Hazardous Materials, 172(23), 14761481.

  13. Kanakaraju, D., Glass, B. D., & Oelgemƶller, M. (2018). Advanced oxidation process-mediated removal of pharmaceuticals from water: A review. Journal of Environmental Management, 219, 189207.

  14. APHA. (2017). Standard Methods for the Examination of Water and Wastewater. American Public Health Association, Washington, DC.

  15. Bureau of Indian Standards. (2006). IS 3025 Part 58: Methods of sampling and test for water and wastewater: Chemical Oxygen Demand.