DOI : 10.17577/IJERTV15IS031798
- Open Access

- Authors : Mr. S. Venkatesh, Dr. N. Nandakumar
- Paper ID : IJERTV15IS031798
- Volume & Issue : Volume 15, Issue 03 , March – 2026
- Published (First Online): 08-04-2026
- ISSN (Online) : 2278-0181
- Publisher Name : IJERT
- License:
This work is licensed under a Creative Commons Attribution 4.0 International License
Design and Prototyping of a Flexible Foot Protection Layer for Diabetic Patients
Mr. S. Venkatesh
Department of Engineering Design Government College of Technology, Coimbatore, India
Dr. N. Nandakumar
Department of Engineering Design Government College of Technology, Coimbatore, India
Abstract – Diabetic foot complications are a major cause of morbidity, often leading to ulcers, infections, and lower-limb amputations due to prolonged pressure, reduced sensation, and impaired wound healing. Effective foot protection plays a crucial role in preventing these complications. This project focuses on the design and prototyping of a flexible foot protection layer specifically intended for diabetic patients to reduce plantar pressure, enhance comfort, and minimize the risk of tissue damage. The proposed system emphasizes the use of lightweight, flexible, and biocompatible materials capable of evenly distributing pressure across the foot surface while adapting to natural foot movements during walking. The design incorporates ergonomic considerations, shock-absorbing properties, and moisture resistance to improve durability and hygiene.
Keywords – Flexible Foot Protection Layer, Patient-Specific Foot Care, (TPU) Ergonomic Foot Design.
- INTRODUCTION
Diabetes is a growing global health concern, The most common and dangerous issues is diabetic foot syndrome, which results from reduced sensation and poor blood flow, leading to wounds and infections. Despite the availability of footwear solutions, many patients find them uncomfortable, ineffective and unaffordable. This project addresses the need for a more flexible, affordable, and comfortable foot protection layer that can reduce prevent injuries. By applying engineering design methods, product lifecycle management, and user-focused design, we aim to develop a prototype that provides practical and impactful protection for diabetic patients. Diabetes mellitus is a chronic metabolic disorder that affects millions of people worldwide, often leading to severe complications, particularly in the lower extremities. Among these, diabetic foot ulcers (DFUs) are one of the most common and serious conditions, frequently resulting in infection, amputation, and reduced quality of life. The primary contributing factor.
[1] Obesity as a body mass index (BMI) of at least 30 kg/m2 is a public health issue of paramount importance with far- reaching musculoskeletal and orthopaedic consequences. The WHO also subdivides BMI into overweight (25-29.9 kg/m2), Class I obesity (30-34.9 kg/m2), Class II obesity (35-39.9 kg/m2), and Class III or morbid obesity (> 40 kg/m2).1 These categories are of prognostic significance to orthopaedic outcomes because higher BMI is significantly associated with greater functional limitation, pain, and surgical burden. [2] These shortcomings limit generalizability and the calculation of the true CPTS experienced in daily life. More advanced CPTS- models that include more input parameters increase the accuracy of CPTS assessment. [3] We assumed that slipper degradation would result in increased heel pressure and stress concentrationin the calcaneus due to reduced sole thickness and uneven sole support. We also hypothesized that foot inversion would further increase the load on the heel, as the altered foot positioning may compromise plantar stability.
- Custom-made footwear designed specifically for indoor use increases footwear adherence in people with diabetes at high ulcer risk. The design and biomechanical requirements of such footwear are important if they are to safely replace regular custom-made footwear for indoor use. We aimed to compare indoor-specific versus regular custom-made footwear for design characteristics and biomechanical function.
- In recent years, many studies have adopted wearable sensor platforms and advanced analytics, including but not limited to machine learning models, to support diagnostics, rehabilitation monitoring and footwear evaluation. The present study therefore addresses a fundamental issue. We examine the extent to which plantar pressure values differ when researchers use different commercial systems, test protocols or usage environments. By documenting these discrepancies, we provide evidence that should caution researchers, product developers and clinicians in any application area, from traditional gait analysis to emerging artificial intelligence pipelines, against pooling or directly comparing data sets collected with incompatible methodologies. Establishing standardised procedures and verifying agreement between devices are essential prerequisites for any robust real-world deployment of plantar pressure technology.
- Another factor that studies should consider its isolated effect is the insole material/structure. Sun et al. conducted an axial compression test to compare two insole materials (silicone and thermoplastic elastomer (TPE)). They conducted the study involving two materials characterized by three hardness values each (Shore-C 15, 20, and 25), and varying thicknesses spanning 6, 8, 10, 12, 14, and 16 mm. The materials were securely positioned and subjected to compression using a predetermined loading-unloading rate (525 and 525 N/s), mimicking the forces experienced during actual walking steps. The simulation aimed to replicate a peak impact of approximately 1.5 times the body weight of an individual weighing around 70 kg. [7] The force was fluctuated between 0 and 1050 N using a load control mode. Notably, after 20 cycles, a considerably more substantial decrease in the hysteresis loop was observed in the silicone material compared to the TPE. proposed a method to increase the efficiency of shoe insoles in various usages tailored by 3D printing. This study used Poly Flex thermoplastic polyurethane (TPU) 90 A, because of its suitable properties to produce the shoe insole. In this study, the design of the insole was taken from the Genola Software.
theoretical models to assess the devices performance across series, parallel, and while charging the batteries will be helpful in better understanding the observed behaviour.
- METHODOLOGY
LITERATURE REVIEW
PROBLEM IDENTIFICATION
MATERIAL SELECTION
DESIGN
PROTOTYPE
Fig.1: Flowchart Methodology
- Literature Review
The Initial phase of the project involves an extensive literature review to gather comprehensive information about the air conditioners and coolers. This review focusses on understanding the current state of cooking techniques and principles of how the evaporation works. It also explores existing studies about material properties, flow configuration, evaporation rate etc.
Previous research about overall air conditioning systems gave the understanding of how the coolers works. The review makes research further by adding the valuable points about coolers and cooling devices.
- Problem Identification
The literature review helps to identify the advantages and disadvantages of vapor compression cycles and evaporative cooling cycles. The vapor compression cycles have a better cooling rate compare to evaporation cooling cycles but it impacts the environment.
The major drawback of the vapor compression cycle is it impacts the climate change and the refrigerants used in vapor compression cycles impacts the ozone layer and its the major factor of ozone layer depletion. Another drawback of the vapor compression cycle is the energy consumption. According to a study half percent of the building electricity is consumed due to vapor compression cycles.
On the other side evaporative cooling cycle is
environmentally friendly and its the major concern of today.
Fig.2: Finger Toe Injured
The reason the evaporative cooling is noted today due to the environmentally friendly nature. According to data, today ten percent of the air conditioning units works on evaporative cooling and 2035 estimated 20 percent of the air conditioners worked by a principle of evaporative cooling. The drawback of the evaporative coolers is the cooling capacity. The project focusses on increasing the cooling capacity of dew point evaporative coolers that benefit the future.
- Material Selection
Fig.3: (TPU) Pellets
TPU A95 refers to Thermoplastic Polyurethane with a Shore a hardness of 95. This places it near the harder end of the soft rubber scale it’s flexible, yet tough. Key Properties of TPU A95: Shore Hardness: A95 (almost rigid, but still flexible) Tensile Strength: ~3050 MPa Elongation at Break: ~300 600% Abrasion Resistance: Excellent Impact Resistance: Good Transparency: Often transparent or translucent Chemical Resistance: Good (resists oils, greases, and many solvents) Temperature Range: -40°C to +80/100°C (depends on grade).
Thermoplastic Polyurethane (TPU) is a versatile elastomer widely used in medical and wearable products because it combines flexibility with mechanical strength. It exhibits excellent elasticity, allowing it to stretch and return to its original shape without permanent deformation, which makes it suitable for cushioning and adaptive foot protection layers.
TPU has good softness that can be tuned by adjusting its hardness (typically measured in Shore A), enabling designers to balance comfort and support for diabetic patients. In terms of thermal behavior, TPU offers moderate heat resistance, generally withstanding temperatures up to around 80120 °C depending on the grade, while maintaining its structural integrity and flexibility under normal usage conditions. It also has strong abrasion resistance and durability, meaning it can endure repeated loading during walking without rapid wear. Additionally, TPU provides good biocompatibility and can be processed through methods like injection molding or 3D
printing, making it ideal for customized, flexible foot protection systems.
Table 1: Mechanical and thermal properties TPU Used in Flexible Foot Protection Layer.
PARAMETER VALUE Nozzle Temperature 200 ~ 240°C (230°C recommended)
Build Platform Temperature Room temperature (40°C recommended) Build Surface Material Tempered glass, Build Tak, Carbon fiber plate Nozzle Diameter 0.4 / 0.6 mm (0.6 mm recommended)
Cooling Fan 50 100% Layer Thickness 0.12 0.3 mm Printing Speed 30 150 mm/s (60 mm/s recommended)
Travel Speed 60 120 mm/s Ambient Temperature for Printing Room temperature 40°C Retraction Distance 0.3 1 mm Retraction Speed 30 50 mm/s TPU (Thermoplastic Polyurethane) pellets are first properly dried because TPU is highly hygroscopic it absorbs moisture from air. If you skip this or do it poorly, the filament will have bubbles, weak spots, and inconsistent extrusion. Typically, pellets are dried at around 50 60 °C for several hours in a dehumidifying dryer. Once dried, the pellets are fed into a filament extrusion machine, where they pass through a heated barrel. Inside the barrel, a rotating screw conveys, compresses, and melts the TPU gradually at controlled temperatures (usually between 180 220 °C depending on grade). The molten TPU is then forced through a precision die nozzle to form a continuous filament strand.
Fig.4: (TPU) White Filament
- DESIN
Curved, Ergonomic Shapes the foot bed appears contoured to fit the arch and heel ideal for comfort and support. The rounded toe and heel region support natural foot movement. Thickness Variation Looks like youve added a thicker sole for cushioning and durability a thinner strap section (especially the grid structure), which allows flexibility across the top of the foot this is great for TPU, which benefits from that deformation.
Fig.5: Front View
The proposed slipper design incorporates a perforated forefoot region consisting of uniformly distributed micro- circular ventilation openings to enhance airflow at the wound interface in patients with Diabetic Foot Ulcer. These strategically placed perforations facilitate continuous air exchange, reducing moisture accumulation and maintaining a dry microenvironment, which is critical for effective wound healing and infection prevention. The ventilation layout is designed to balance breathability with structural integrity, ensuring that the protective function of the slipper is not compromised while promoting improved thermal and moisture regulation.
Fig.6: Top View
The top-view design of the proposed slipper integrates a dual-functional surface comprising strategically distributed ventilation perforations and acupressure nodules to support wound healing in patients with Diabetic Foot Ulcer. The
forefoot region incorporates an array of micro-perforations that facilitate continuous air circulation, thereby reducing moisture accumulation and maintaining a dry microenvironment essential for infection control and tissue repair. In parallel, the insole surface is embedded with anatomically positioned acupressure elements designed to stimulate plantar regions associated with improved blood circulation. This combined approach aims to enhance localized perfusion, reduce tissue stress, and accelerate the healing process while maintaining user comfort and structural stability. The integrated design provides both mechanical protection and physiological support, offering a comprehensive solution for diabetic foot care.
Fig.7: Back View
The rear-side (outsole) design of the proposed slipper incorporates a flexible, high-friction grip pattern to enhance stability and prevent slipping in wet and slurry-prone environments, which is critical for patients with Diabetic Neuropathy. The outsole is engineered with a textured tread geometry that improves surface contact and traction, thereby reducing the risk of accidental falls and secondary injuries. The flexible material composition allows the sole to adapt to varying ground conditions while maintaining consistent grip performance. This design feature not only enhances user safety but also supports confident mobility in daily activities, addressing a key risk factor associated with diabetic foot complications.
The outsole is designed with a high-friction, slip-resistant surface to enhance traction and stability during walking. The textured tread pattern increases ground contact and effectively reduces the risk of slipping, particularly on wet or low-friction surfaces. This feature is especially important for individuals affected by Diabetic Neuropathy, where reduced sensory feedback increases the likelihood of imbalance and falls. The combination of flexible material properties and optimized grip geometry ensures improved safety and controlled movement during daily use.
Fig.8: Side View
The side-view design of the proposed slipper illustrates a flexible and ergonomically contoured structure developed specifically to enhance safety and wound healing in patients with Diabetic Foot Ulcer. The profile incorporates an elevated and ventilated midsole architecture that facilitates continuous airflow beneath the foot, promoting a dry and temperature- regulated microenvironment essential for tissue recovery. The flexible construction allows natural foot movement while maintaining adequate support and protection against external impacts. Additionally, the design ensures uniform weight distribution along the plantar surface, reducing localized stress on vulnerable regions. This integrated approach combines safety, comfort, and therapeutic functionality, making the slipper suitable for daily use in diabetic foot care management.
Fig.9: Isometric View
The increasing prevalence of foot-related complications in diabetic individuals necessitates the development of effective protective solutions that address both mechanical and physiological factors associated with wound formation and delayed healing. In particular, patients affected by Diabetic Foot Ulcer require continuous protection from external stress, excessive moisture, and poor circulation, all of which contribute to tissue breakdown. The present work focuses on the design and prototyping of a flexible foot protection system that integrates ventilation, pressure distribution, and safety features into a single wearable solution.
The proposed design is based on a thermoplastic polyurethane (TPU) structure due to its flexibility, durability, and adaptability to complex geometries. The slipper incorporates an anatomically contoured profile that conforms to the plantar surface of the foot, enabling uniform load distribution
and reducing localized pressure points that commonly lead to ulcer formation. Unlike conventional footwear that primarily relies on cushioning, the current design adopts a multifunctional approach by integrating engineered ventilation pathways within the forefoot region. These micro-perforations are strategically distributed to facilitate continuous air circulation, thereby maintaining a dry and temperature-regulated microenvironment at the skin interface. This feature is particularly critical in minimizing moisture accumulation, which is a known factor in bacterial growth and delayed wound healing.
- PROTOTYPE
The prototype of the proposed flexible foot protection system was fabricated using thermoplastic polyurethane (TPU) material through fused deposition modeling (FDM) on a Bambu Lab 3D Printer. TPU was selected due to its high flexibility, abrasion resistance, and suitability for wearable medical applications. Prior to printing, the TPU filament was properly dried to eliminate moisture content, ensuring consistent extrusion and surface quality. The printing process was carried out under controlled thermal conditions to achieve optimal layer adhesion and dimensional stability. A nozzle temperature range of 210 230 °C was maintained to ensure smooth material flow, while the build plate temperature was set between 40 60 °C to improve bed adhesion and minimize warping. The print speed was reduced compared to rigid materials to accommodate the elastic nature of TPU, thereby preventing filament buckling and ensuring geometric accuracy. The completed prototype demonstrated good flexibility, structural integrity, and surface finish, confirming the suitability of the selected material and process parameters for fabricating a functional wearable device.
Fig.10: Bambu Lab 3D Printer
The prototype of the proposed flexible foot protection system was fabricated using thermoplastic polyurethane (TPU) filament through fused deposition modeling (FDM) on a Bambu Lab 3D Printer. Prior to printing, the TPU filament was properly dried to eliminate moisture absorption, ensuring consistent extrusion quality and preventing defects such as bubbling and poor layer adhesion. The printing process was carried out with a nozzle temperature maintained in the range of 210230 °C, which is optimal for achieving uniform material flow and interlayer bonding in TPU. The build plate temperature was set between 4060 °C to enhance bed adhesion while preventing excessive softening of the initial layers. A reduced printing speed of 2040 mm/s was employed due to the flexible nature of TPU, allowing controlled extrusion and minimizing filament
deformation during deposition. Retraction settings were minimized or disabled to avoid stringing and material cloggng,
Fig.11: (TPU) Material Printing on 3D Printer
which are common challenges in flexible filament printing. Additionally, a direct-drive extrusion system was utilized to ensure precise filament feeding and improved print stability.
Table.2: Thermoplastic Polyurethane (TPU) Behavior and Print Parameter Considerations in Additive Manufacturing
Material Behavior Awareness Property Behavior During Printing Flexibility Soft filament Can bend and compress in extruder Flow Behavior Viscous melt Smooth but sensitive to temperature Stringing High tendency Causes thin unwanted threads Layer Adhesion Strong bonding Good interlayer strength Warping Low Minimal shrinkage Moisture Effect Absorbs water Leads to bubbles and weak layers Surface Finish Slightly rough Depends on cooling and speed The layer height was maintained at approximately 0.2 mm to balance surface finish and structural integrity. These controlled parameters enabled the successful fabrication of a flexible, durable, and geometrically accurate prototype suitable for functional evaluation in diabetic foot care applications.
The outsole of the slipper is engineered with a high-friction, slip-resistant tread pattern to improve traction on various surfaces, including wet and uneven conditions. This is particularly important for individuals with reduced sensory feedback due to Diabetic Neuropathy, where the risk of accidental slips and falls is significantly increased. The combination of flexibility and grip ensures both safety and stability during daily activities.
- Final Output Product
Fig.12: Top View Prototype
The final prototype of the proposed slipper was successfully fabricated using TPU material through additive manufacturing, resulting in a flexible and functionally integrated foot protection device. The developed model was designed to accommodate a unisex size range, ensuring adaptability and comfort for a wide spectrum of users.
Fig.13: Back Side View Prototype
The prototype demonstrated effective integration of key features, including ventilation perforations for enhanced airflow, acupressure-inspired insole elements for plantar stimulation, and a slip-resistant outsole for improved safety. The flexible structure allowed the slipper to conform to the natural contours of the foot, promoting uniform load distribution and reducing localized stress on vulnerable regions.
These characteristics are particularly beneficial for individuals affected by Diabetic Foot Ulcer, where protection, moisture control, and comfort are essential for wound management. Overall, the fabricated model exhibited satisfactory performance in terms of flexibility, fit, and functional design, indicating its potential as a supportive and preventive solution in diabetic foot care applications.
The flexible structure facilitates uniform load distribution across the plantar region, thereby reducing localized stress
concentrations associated with tissue damage. These combined features are particularly relevant for individuals affected by Diabetic Foot Ulcer, where pressure management and moisture controlled.
- Literature Review
- FUTURE WORK
Further improvements will include the integration of embedded pressure and humidity sensors for real-time monitoring of foot conditions, enabling early detection of high- risk zones. In addition, material optimization will be explored to enhance durability, biocompatibility, and long-term comfort through advanced polymer blends.
- REFERENCES
- © 2025 Published by Elsevier B.V. Gobal on behalf of Prof. PK Surendran Memorial Education Foundation. 26.10.2025
- Chantal M. Hulshof, Jaap J. van Netten, Caroline M. Oosterhof, Jonne vans dipole, Mirjam Pijnappels, Sicco A. 11 January 2024 0021-9290/© 2024 The Author(s). Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license.
- Yang Song, Xuanzhen Cen, Meizi Wang, Kov´acs B, Qitao Tan, Dong Sun, 7 January 2025 Shunxiang Gao, Fengping Li, Wang, Ming Zhang.
- L.E. Vossen, J.J. van Netten, T.E. Busch Westbroek,
S.A. Bus. 27 June 2025 (0268-0033)
- Nachiappan Chockalingam, Claudia Giacomozzi, Aoife Healy, Isabel C.N. Sacco Accepted 15 July 2025 the Foot 64 (2025) 102190 Available online 23
July 2025 (0958-2592).
- Mohammad Mahdi Mohammadi, Amir Nourani, Tehran. 20 February 2025 (2405-8440).
- Z. Shaghayegh Bagheri, Yue Li, Atena Roshan Fekr, Tilak Dutta 9 November 2021 (0003-6870).
- Davood Dadkhah, Hamed Ghomashchi, Tilak Dutta 18 March 2025 (0003-6870).
- Chahine Ghimouz, Jean Pierre Kenn´e, Lucas A. Hof 5 August 2023 (0264-1275).
- Kaylie Lau, Geoff Fernie, Atena Roshan Fekr, 24 October 2024 (0925-7535).
- Eleonora Bianca, Antonio Buffo, Marco Vanni, Ada Ferri. 8 July 2025 (1290-0729).
- Shubham Gupta, Mithil Kumar, Gurpreet Singh, Arnab Chanda. 18 January 2023 (2772-6711).
- Gao, C., Abeysekera, J., 2022. A systems perspective of slip and fall accidents on icy and snowy surfaces. Ergonomics 47, (573598).
- M. Harsola, Embedded Stethoscope for Heart Sounds, International Journal of Advanced Computer Research, vol. 2, no. 6, pp. 151-155, 2021.
- Barton, C.J., Bonanno, D., Menz, H.B., 2020. Development and evaluation of a tool (1757-1146).